• 제목/요약/키워드: Scan Impedance

검색결과 46건 처리시간 0.026초

Investigation of a Pseudo Capacitor with Polyacrylonitrile based Gel Polymer Electrolyte

  • Harankahawa, Neminda;Weerasinghe, Sandaranghe;Vidanapathirana, Kamal;Perera, Kumudu
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권2호
    • /
    • pp.107-114
    • /
    • 2017
  • Pseudo capacitors belong to one group of super capacitors which are consisted with non carbon based electrodes. As such, conducting polymers and metal oxide materials have been employed for pseudo capacitors. Conducting polymer based pseudo capacitors have received a great attention due to their interesting features such as flexibility, low cost and ease of synthesis. Much work has been done using liquid electrolytes for those pseudo capacitors but has undergone various drawbacks. It has now been realized the use of solid polymer electrolytes as an alternative. Among them gel polymer electrolytes (GPEs) are in a key place due to their high ambient temperature conductivities as well as suitable mechanical properties. In this study, composition of a polyacrylonitrile (PAN) based GPE was optimized and it was employed as the electrolyte in a pseudo capacitor having polypyrrole (PPy) electrodes. GPE was prepared using ethylene carbonate (EC), propylene carbonate (PC), sodium thiocyanate (NaSCN) and PAN as starting materials. The maximum room temperature conductivity of the GPE was $1.92{\times}10^{-3}Scm^{-1}$ for the composition 202.5 PAN : 500 EC : 500 PC : 35 NaSCN (by weight). Performance of the pseudo capacitor was investigated using Cyclic Voltammetry technique, Electrochemical Impedance Spectroscopy (EIS) technique and Continuous Charge Discharge (GCD) test. The single electrode specific capacity (Cs) was found out to be 174.31 F/g using Cyclic Voltammetry technique at the scan rate of 10 mV/s and within the potential window -1.2 V to 1.2 V. The same value obtained using EIS was about 84 F/g. The discharge capacity ($C_d$) was 69.8 F/g. The capacity fade over 1000 cycles was rather a low value of 4%. The results proved the suitability of the pseudo capacitor for improving the performance further.

CNT를 이용한 Supercapacitor의 충.방전 특성 (The Effect of CNT Electrode on the Charging and Discharging Characteristics of Supercapacitor)

  • 허근;명성재;이용현;전명표;조정호;김병익;심광보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.275-275
    • /
    • 2007
  • Two sorts of electrode composed of Sulpur/CNT/PVDF and Silver/CNT/PVDF were prepared by in situ chemical method and their electrochemical performance were evaluated by using cyclic voltammetry, impedance measurement and constant-current charge/discharge cycling technique. Also, composite electrodes were characterized by FE-SEM and BET. Raw materials such as CNT/Silver and CNT/Sulfur were mixed in ethanol, dried. These mixed materials were heated at 900 and $320^{\circ}C$ for 2hr, respectively in order to enhance contact among CNT electrodes. Electric double layer capacitor cells were fabricated using these mixed powder with polymer of PVDF. For the charging and discharging characteristics measured at scan rate of 1 mA/s, Supercapacitor of Sulphur-CNT-PVDF electrode showed a better performance than that of Ag-CNT-PVDF, which seems to be related with lower contact resistance of Sulphur-CNT-PVDF electrode.

  • PDF

전기화학 증착법을 이용한 그래핀 개질 Indium Tin Oxide 전극 제작 및 효소 전극에 응용 (Fabrication of Graphene-modified Indium Tin Oxide Electrode Using Electrochemical Deposition Method and Its Application to Enzyme Electrode)

  • 왕설;시키;김창준
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.62-69
    • /
    • 2022
  • 그래핀은 부피에 비해 표면적이 넓고 뛰어난 기계적 물성과 전기전도성을 가지며 생체적합성이 우수하다. 본 연구에서는 전기화학적 방법을 이용하여 indium tin oxide (ITO) 글래스 슬라이드 표면에 산화그래핀을 증착·환원시킨 전극을 제작하였고 그래핀으로 표면 개질된 ITO의 전기화학적 특성을 조사하였다. 산화그래핀의 증착과 환원에 순환전압전류법을 사용하였다. 주사전자현미경과 에너지 분산형 X-선 분광법을 사용하여 그래핀이 코팅된 ITO 표면을 관찰하였다. 순환전압전류법과 전기화학 임피던스 분광법을 사용하여 제작된 전극들의 전기화학 특성을 평가하였다. 사이클 수와 주사 속도는 산화그래핀 증착과 환원도에 상당한 영향을 미쳤으며 제작된 전극의 전기화학 특성도 달랐다. ITO 전극에 비하여 그래핀으로 표면 개질된 ITO는 전극 계면에서의 전하 전달 저항이 낮았고 더 많은 전류를 생산하였다. 그래핀으로 표면 개질된 ITO 표면에 고정화된 포도당 산화효소는 포도당을 산화시키며 성공적으로 전자들을 생성하였다.

Determination of Ascorbic Acid, Acetaminophen, and Caffeine in Urine, Blood Serum by Electrochemical Sensor Based on ZnO-Zn2SnO4-SnO2 Nanocomposite and Graphene

  • Nikpanje, Elham;Bahmaei, Manochehr;Sharif, Amirabdolah Mehrdad
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권2호
    • /
    • pp.173-187
    • /
    • 2021
  • In the present research, a simple electrochemical sensor based on a carbon paste electrode (CPE) modified with ZnO-Zn2SnO4-SnO2 and graphene (ZnO-Zn2SnO4-SnO2/Gr/CPE) was developed for the direct, simultaneous and individual electrochemical measurement of Acetaminophen (AC), Caffeine (Caf) and Ascorbic acid (AA). The synthesized nano-materials were investigated using scanning electron microscopy, X-ray Diffraction, Fourier-transform infrared spectroscopy, and electrochemical impedance spectroscopy techniques. Cyclic voltammetry and differential pulse voltammetry were applied for electrochemical investigation ZnO-Zn2SnO4-SnO2/Gr/CPE, and the impact of scan rate and the concentration of H+ on the electrode's responses were investigated. The voltammograms showed a linear relationship between the response of the electrode for individual oxidation of AA, AC and, Caf in the range of 0.021-120, 0.018-85.3, and 0.02-97.51 μM with the detection limit of 8.94, 6.66 and 7.09 nM (S/N = 3), respectively. Also, the amperometric technique was applied for the measuring of the target molecules in the range of 0.013-16, 0.008-12 and, 0.01-14 μM for AA, AC and, Caf with the detection limit of 6.28, 3.64 and 3.85 nM, respectively. Besides, the ZnO-Zn2SnO4-SnO2/Gr/CPE shows an excellent selectivity, stability, repeatability, and reproducibility for the determination of AA, AC and, Caf. Finally, the proposed sensor was successfully used to show the amount of AA, AC and, Caf in urine, blood serum samples with recoveries ranging between 95.8% and 104.06%.

쌀밥으로 제조된 활성탄을 사용하는 전기이중층형 슈퍼커패시터 전극의 전기화학적 특성 (Electrochemical Characteristics of an Electric Double Layer Supercapacitor Electrode using Cooked-Rice based Activated Carbon)

  • 조운;김용일;윤재국;유정준;윤하나;김성수;김종휘
    • 전기화학회지
    • /
    • 제16권3호
    • /
    • pp.129-137
    • /
    • 2013
  • 쌀밥을 출발물질로 활용하고 수열합성법과 화학적 활성화를 위한 KOH용액 진공함침 등의 방법으로 제조된 활성탄의 전기이중층 초고용량 커패시터의 전극에 대한 전기화학적 전극특성을 확인 하였다. 제조된 활성탄의 물성을 SEM, EDS, XRD, TG, 비표면적, 기공크기 분포 등의 분석을 통해 조사하였다. 또한, 슈퍼커패시터의 전극에 대한 순환전류 측정과 교류 임피던스 측정 실험을 통해 전기화학적 특성을 확인하였다. 수열합성법을 통하여 직경 $5{\sim}7{\mu}m$ 인 구형의 탄소 입자를 얻었으며 활성화 온도 $800^{\circ}C$로 제조된 활성탄은 비표면적이 $1631.8cm^2/g$, 기공크기 분포가 0.9~2.1 nm에 집중적으로 분포하였으며, 마이크로 기공체적이 $0.6154cm^3/g$ 임을 알 수 있었다. 이 활성탄을 사용하여 제작된 전극은 6M KOH 전해액에서 비용량 236 F/g(@5 mV/s), 194 F/g(@100 mV/s), 137 F/g(@500 mV/s)의 우수한 특성을 나타내었다. 충방전 싸이클 수명시험 결과, 200 mV/s의 주사속도에서 100,000회 충방전 시험 후에도 초기용량 대비 91.2%의 용량을 유지함을 확인하였다.

폐색전증의 진단에 있어 혈청 D-dimer 측정의 진단적 가치 (Plasma D-dimer Determination in the Diagnosis of Pulmonary Embolism)

  • 임채만;김홍규;최강현;이상도;고윤석;김우성;장재석;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권1호
    • /
    • pp.69-74
    • /
    • 1996
  • 연구배경: 폐색전증의 진단에 있어 확전법인 폐동맥 조영술은 관혈적이고 임상에서의 제약이 있으며, 폐환기-관류주사는 비고확률 소견인 경우 진단적 민감도 및 특이도가 낮은 문제가 있다. 혈장 D-dimer는 섬유소분 해산물로 임상적으로 폐색전증이 의심되는 환자에서 증가되는 것이 알려져 있어 혈장 D-dimer의 측정이 폐색전증에 있어 어떤 진단적 가치가 있는지 알아보고자 하였다. 방법: 전향적 임상연구로 정상대조군 21예와 폐색전증 환자군 9예에서 latex agglutination법에 의해 혈장 D-dimer를 측정하고 폐동맥조영술 결과와 비교하였다. 결과: 1) 대조군 및 폐색전증군의 혈장 D-dimer치; 대조군의 혈장 D-dimer치는 21예중 0.5 mg/L 미만 11예, 0.5 mg/L 보다 높은 경우 10예 였고, 폐색전증군 9예중 0.5 mg/L 미만 1예, 0.5 mg/L 보다 8예로 혈장 D-dimer치가 0.5 mg/L 이상으로 증가된 양성율은 폐색전증군에서 대조군에 비해 유의하게 많았다(p=0.049). 2) 혈장 D-dimer치의 진단적 효용; 혈장 D-dimer치 0.5 mg/L를 cut-off으로 했을 때 폐색전증 진단의 민감도 88.9%(8/9), 특이도 52.4%(11/21), 양성예측치 44.4%(8/18) 및 음성 예측치 91.7%(11/12)였다. 결론: 폐색전증의 진단에 있어 D-dimer의 측정치가 cut-off(0.5 mg/L)치 이내인 경우 폐색전증의 존재 가능성은 매우 적을 것으로 사료되었다.

  • PDF