• 제목/요약/키워드: Scan Delay Time

Search Result 74, Processing Time 0.026 seconds

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Study of SUVm Cut-off Value for the Distinction of Pancreatic Cancer In PET/CT Exam (PET/CT 검사에서 췌장암 판별을 위한 SUVm 경계값 연구)

  • Chang, Boseok;Kim, Jae Ho;Liu, Guoxu;Jang, Eun Sung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.567-575
    • /
    • 2017
  • In this study, when diagnosis pancreatic cancer by dual time point PET/CT, we propose SUVm 2.52 as the threshold value for performing the dual time point PET/CT exam. The hypothesis of normal distribution was adopted through data conversion of 60 pancreatic diseases. The proposed SUVm2.52 boundary value showed a significance level that could be applied to both 120 and 180 minutes of delay time scan for pancreatic cancer determination (p<0.05). C-value variation shows that delay time 2 hour test is more useful than delay time 3 hour test. When the SUVm 2.52 is set to the boundary value and the double-time point PET/CT exam is performed, the probability of distinguishing cancer from inflammation in the delayed image is 95%. When the delayed test is performed with the proposed boundary value SUVm 2.52, Compared with general PET / CT scans, it is thought that it may be helpful to distinguish pancreatic cancer.

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Analysis of System Instability Factors in a Bistatic Radar (바이스태틱 레이더의 시스템 불안정 요소들에 대한 분석)

  • Yang, Jin-Mo;Lee, Min-Joon;Yun, Jae-Ryong;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.114-122
    • /
    • 2011
  • In this paper, we have identified the system instability factors in a bistatic radar system using pulse chasing and considered their effects on the bistatic receiver's MTI(Moving Target Indication) improvement performance. The pulse chasing is a method to efficiently scan a restricted search area within the limited transmitter power and time in a bistatic radar and to track a series of transmitted pulses using the receiver beam which has ideally matched to the pulse propagation rate. In this paper, we have discussed the interrelationship between the pulse chasing and time and frequency/phase synchronization and described the effects of the identified system instability factors on two kinds of MTI filter configuration, single delay-line and double delay-line, in the bistatic radar. And also, we have confirmed that the overall system improvement is restricted by a lower improvement factor among identified them, and discussed the allowable tolerance of the time and frequency/phase synchronization in the bistatic system.

Cancerous Transfer Evaluation which Presumes as Prosecuting Attorney Nuclear Medicine (핵의학적 검사로 추정한 암 전이 평가)

  • Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.236-245
    • /
    • 2008
  • The cancer patient who leads Bone scan and the PET study from in the nuclear medical study what is enforced with the link of early detection and the time which spreads, it will be able to accomplish a positive treatment with the data which presumes that time it researches a degree as cancer discovery initially and only difference of final period the bay it knows. The patient who receives a cancer decision it will be able to accomplish the necessary defense it will be able to delay the time in order, the maximum control the possibility of doing will be becomes the judgement. Cancer decision to initially the nuclear study and treatment it will be in parallel with effort and the investment which are constant and the schedule hour will elapse and to after difficulty some the case which comes to be negligent will be frequent and it will appear with him there to be a possibility of knowing, it will be caused by and the transfer of the cancer sell will be activity. It has a treatment objective and are to each medical treatment agency against and the medical treatment agency worker it will be able to overlook is not the portion is the private plan which needs a more positive disposal, it does.

Ultrasound Synthetic Aperture Beamformer Architecture Based on the Simultaneous Multi-scanning Approach (동시 다중 주사 방식의 초음파 합성구경 빔포머 구조)

  • Lee, Yu-Hwa;Kim, Seung-Soo;Ahn, Young-Bok;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.803-810
    • /
    • 2007
  • Although synthetic aperture focusing techniques can improve the spatial resolution of ultrasound imaging, they have not been employed in a commercial product because they require a real-time N-channel beamformer with a tremendously increased hardware complexity for simultaneous beamforming along M multiple lines. In this paper, a hardware-efficient beamformer architecture for synthetic aperture focusing is presented. In contrast to the straightforward design using NM delay calculators, the proposed method utilizes only M delay calculators by sharing the same values among the focusing delays which should be calculated at the same time between the N channels for all imaging points along the M scan lines. In general, synthetic aperture beamforming requires M 2-port memories. In the proposed beamformer, the input data for each channel is first upsampled with a 4-fold interpolator and each polyphase component of the interpolator output is stored into a 2-port memory separately, requiring 4M 2-port memories for each channel. By properly limiting the area formed with the synthetic aperture focusing, the input memory buffer can be implemented with only 4 2-port memories and one short multi-port memory.

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

Development of a Tool for the Electrical Analysis and Design of TFT/LCD System Package (TFT/LCD 시스템 패키지 전기적 특성 분석 및 설계도구의 구현)

  • Yim, Ho-Nam;Jee, Yong
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.149-158
    • /
    • 1995
  • This paper describes the development of a software tool LCD FRAME that may guide the analyzing process for the electrical characteristics and the design procedure for constructing the thin film transistor liquid crystal display(TFT/LCD) packages. LCD FRAME can analyze its electrical characteristics from the TFT/LCD system package configuration, and provide the design variables to meet the user's requirements. These analysis and design procedure can be done in real time according to the model at simplified package level of TFT/LCD. LCD_FRAME is an object-oriented expert system which considers package elements as objects. With this LCD_FRAME software tool, we analyzed the I-V characteristics of a-Si TFT and its signal distortion which has maximum 1.58 $\mu$s delay along the panel scan line of the package containing 480 ${\times}$ 240 pixels. We designed the package structure of maximum 6.35 $\mu$s signal delays and 3360 ${\times}$ 780 pixels, and as a result we showed that the proper structure of 20 $\mu$m scan line width, 60$\mu$m panel TFT gate width and 8 $\mu$m gate length. This LCD_FRAME software tool provides results of the analysis and the design in the form of input files of the SPICE program, text data files, and graphic charts.

  • PDF

Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order (동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구)

  • Byun, Jae-Hoo;Park, Myung-Hwan;Kang, Ji-Yeon;Lee, Jin-Wan;Lee, Kang-Won;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.108-118
    • /
    • 2013
  • Currently, an arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique does not routinely used in clinical studies to measure perfusion in brain because optimization of imaging protocol is required to obtain optimal perfusion signals. Therefore, the objective of this study was to investigate changes of perfusion-weighed signal intensities with varying several parameters on a pulsed arterial spin labeling MRI technique obtained from a 3T MRI system. We especially evaluated alternations of ASL-MRI signal intensities on special brain areas, including in brain tissues and lobes. The signal targeting with alternating radiofrequency (STAR) pulsed ASL method was scanned on five normal subjects (mean age: 36 years, range: 29~41 years) on a 3T MRI system. Four parameters were evaluated with varying: 1) the labeling gap, 2) the labeling delay time, 3) the labeling thickness, and 4) the slice scan order. Signal intensities were obtained from the perfusion-weighted imaging on the gray and white matters and brain lobes of the frontal, parietal, temporal, and occipital areas. The results of this study were summarized: 1) Perfusion-weighted signal intensities were decreased with increasing the labeling gap in the bilateral gray matter areas and were least affected on the parietal lobe, but most affected on the occipital lobe. 2) Perfusion-weighted signal intensities were decreased with increasing the labeling delay time until 400 ms, but increased up to 1,000 ms in the bilateral gray matter areas. 3) Perfusion-weighted signal intensities were increased with increasing the labeling thickness until 120 mm in both the gray and white matter. 4) Perfusion-weighted signal intensities were higher descending scans than asending scans in both the gray and white matter. We investigated changes of perfusion-weighted signal intensities with varying several parameters in the STAR ASL method. It should require having protocol optimization processing before applying in patients. It has limitations to apply the ASL method in the white matter on a 3T MRI system.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.