Abstract
This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.
Keywords
Contrast medium(CM); Cardiac CT angiography(CTA); Empirical method; Radiation exposure;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 B. K. Han, J. Lindberg, K. Grant, R. S. Schwartz, J. R. Lesser, "Accuracy and safety of high pitch computed tomography imaging in young children with complex congenital heart disease", Am. J. Cardiol., Vol. 107, No. 10, pp. 1541-1546, 2011.   DOI   ScienceOn
2 M. Satpathy, "Clinical diagnosis of congenital heart disease", 1st edit., Jaypee Brothers Publishers Ltd., New Delhi, pp. 22-24, 2008.
3 P. Daubeney, M. Rigby, M. Gatzoulis, M. Niwa, "Pediatric heart disease: a clinical guide", 1st edit., John Wiley & Sons., Oxford, UK, pp. 142-145, 2012.
4 U. J. Schoepf, C. R. Becker, B. M. Ohnesorge, E. K. Yucel, "CT of Coronary Artery Disease", Radiology, Vol. 232, No. 1, pp. 18-37, 2004.   DOI   ScienceOn
5 H. W. Goo, "State of the Art CT Imaging Techniques for Congenital Heart Disease", Korean J Radiol., Vol. 11, No. 1, pp.4-18, 2010.   과학기술학회마을   DOI   ScienceOn
6 M. J. Siegel, S. Bhalla, F. R. Gutierrez, et al., "MDCT of postoperative anatomy and complications in adults with cyanotic heart disease" AJR. Am. J. Roentgenol., Vol. 184, No. 1, pp. 241-247, 2005.   DOI   ScienceOn
7 D. P. Frush, J. R. Herlong, "Pediatric thoracic CT angiography", Pediatr. Radiol., Vol. 35, No. 1, pp. 11-25, 2005.   DOI
8 P. Dawson, M. Blomley, "The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastases", Eur. J. Radiol., Vol. 41, No. 3, pp. 222-236, 2002.   DOI   ScienceOn
9 K. T. Bae, "Peak contrast enhancement in CT and MR angiography: when does it occur and why? pharmacokinetic study in a porcine model", Radiology, Vol. 227, No. 3, pp.809-816, 2003.   DOI   ScienceOn
10 S. T. Schindera, R. C. Nelson, L. Howle, E. Nichols, D. M. DeLong, E. M. Merkle, "Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study", Eur. Radiol., Vol. 18, No. 8, pp. 1683-1689, 2008.   DOI
11 P. Dawson, M. Blomley, "The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastases", Eur J Radiol., Vol. 41, No. 3, pp. 222-236, 2002.   DOI   ScienceOn
12 D. P. Frush, J. R. Herlong, "Pediatric thoracic CT angiography", Pediatr. Radiol., Vol. 35, No. 1, pp. 11-25, 2005.   DOI