Browse > Article
http://dx.doi.org/10.7742/jksr.2011.5.2.051

Protocol Optimization of Coronary CT Angiography  

Lee, Hae-Kag (Department of Computer Science and Soonchunhyang University)
Yoo, Heung-Joon (Department of Radiology, Asan Medical Centerer)
Lee, Sun-Yeob (Department of Radiological Science, Hanlym College)
Goo, Eun-Hoe (Department of Radiology, Seoul Nationnal University Hospital)
Seok, Jong-Min (Department of Radiology, Nationnal Police Hospital)
Han, Man-Seok (Department of Radiology, Chungnam University Hospital)
Lee, Kwang-Sung (Department of Radiological Technology, Daejeon Health Sciences College)
Cho, Jae-Hwan (Department of Radiological Science, Gyeonesan University College)
Kim, Bo-Hui (Department of Emergency Center, Gangneung Asan Hospital)
Park, Cheol-Soo (Department of Radiological Science, Hanlym College)
Publication Information
Journal of the Korean Society of Radiology / v.5, no.2, 2011 , pp. 51-58 More about this Journal
Abstract
This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.
Keywords
Dual source computed tomography; Coronary CT Angiogrphy; LVEF;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kim Dong Hoon, "관상동맥 전산화단층촬영 혈관조영술: 새로운 진단기법으로서 임상에서의 적응증 및 역할을 중심으로", 대한 영상의학회지, Vol.56, No.2, PP.431-437, 2007
2 Choi Sang Yil, "허혈성 심질환의 다검출기 CT 영상 진단," 대한 영상의학회지, Vol.23, No.2, PP.127-135, 2004
3 Lim Soo Jin, "비전형적 흉통 :저 선량 흉부 CT를 포함한 CT 관상동맥 조영 술의 임상적 유용성," 대한 영상의학회지, Vol.58, No.3, PP.351-56, 2008
4 Oh You Hwan, "다중검출기 CT (Multidetector-row CT)의 원리와 임상적 적응," 가정의학회지, Vol.27, No.3, PP.249-256, 2006
5 Dominik Ketelsen, "Estimation of the radiation exposure of a chestpain protocol with ECG-gating in dual-sourcecomputed tomography," Eur Radiology. Vol.19, No.3, PP.37-41, 2009   DOI
6 David Maintz, "Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT," Eur Radiology. Vol.19, No.3, PP.42-49, 2009   DOI
7 Yu Mi Jeong, "Evaluation of Coronary Artery Bypass Grafts in the Early Postoperative Period Using 64-Slice MDCT," 대한 영상의학회지, Vol.60, No.3, PP.303-312, 2009
8 Kang Heung Shik, "비침습적 심장혈관영상: CT 및 MRI의 최신 발전 동향," 대한 흉부외과학회, Vol.33, No.1, PP.117-123, 2005
9 Lee Hwal, "Cadiac CT: From Basic to Clinical Application," 서울대 병원 순환기내과 연수 강좌, PP.25, 2007