• Title/Summary/Keyword: Scan Code

Search Result 77, Processing Time 0.023 seconds

Development of Mobile Camera Vision System and Build of Wire.Wireless Integration ERP System (모바일 카메라 비전 시스템 개발과 유.무선 통합 ERP 시스템 구축)

  • Lee, Hyae-Jung;Shin, Hyun-Cheol;Joung, Suck-Tae
    • Convergence Security Journal
    • /
    • v.7 no.2
    • /
    • pp.81-89
    • /
    • 2007
  • Mobile computing environment that support so that can offer employees inside information that enterprise has always improves business productivity and fetches efficiency enlargement. In this paper, limit model that can process ERP information by real-time as easy and convenient always utilizing radio network and PDA, Mobile camera based on Mobile vision concept. Calculable information between seller and customer is supplied supplying real-time brand image and information by practical use of Enterprise Resource Planning doing based on Mobile. Technical development and commercialization that utilize mobility, enforcement stronghold, portability etc. that is advantage of Mobile communication are required. In this paper, mobility of precious metals.jewel field that use portable terminal equipment taking advantage of a Mobile technology is secured. Constructed Mobile vision system that satisfy photography and bar-code scan at the same time from Mobile camera.

  • PDF

An Efficient Architecture of Transform & Quantization Module in MPEG-4 Video Code (MPEG-4 영상코덱에서 DCTQ module의 효율적인 구조)

  • 서기범;윤동원
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.11
    • /
    • pp.29-36
    • /
    • 2003
  • In this paper, an efficient VLSI architecture for DCTQ module, which consists of 2D-DCT, quantization, AC/DC prediction block, scan conversion, inverse quantization and 2D-IDCT, is presented. The architecture of the module is designed to handle a macroblock data within 1064 cycles and suitable for MPEG-4 video codec handling 30 frame CIF image for both encoder and decoder simultaneously. Only single 1-D DCT/IDCT cores are used for the design instead of 2-D DCT/IDCT, respectively. 1-bit serial distributed arithmetic architecture is adopted for 1-D DCT/IDCT to reduce the hardware area in this architecture. To reduce the power consumption of DCTQ modu1e, we propose the method not to operate the DCTQ modu1e exploiting the SAE(sum of absolute error) value from motion estimation and cbp(coded block pattern). To reduce the AC/DC prediction memory size, the memory architecture and memory access method for AC/DC prediction block is proposed. As the result, the maximum utilization of hardware can be achieved, and power consumption can be minimized. The proposed design is operated on 27MHz clock. The experimental results show that the accuracy of DCT and IDCT meet the IEEE specification.

Enhanced Local Directional Pattern based video shot boundary detection and automatic synchronization for STB quality inspection (STB 품질검사를 위한 개선된 지역 방향 패턴 기반 비디오 샷 경계 검출 및 자동 동기화)

  • Cho, Youngtak;Chae, Oksam
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.3
    • /
    • pp.8-15
    • /
    • 2019
  • Recently, the importance of pre-shipment quality inspection has been emphasized due to the increase of STB supply. In this paper, we propose a method to support automation of quality inspection through simultaneous multi-channel input of STB video signal. The proposed method extracts a fingerprint using the center scan line of the image after stable video shot boundary detection using CeLDP combining color information and LDP code and performs synchronization between input video channels. The proposed method shows stronger shot boundary detection performance than the conventional shot detection method. Through the experiments applied to the real environment, it is possible to secure reliability and real-time quality check for synchronization between multi-channel inputs required for STB quality inspection. Also, based on the proposed method, we intend to study a large-scale quality inspection method in the future and propose a more effective quality inspection system.

Segmentation of underwater images using morphology for deep learning (딥러닝을 위한 모폴로지를 이용한 수중 영상의 세그먼테이션)

  • Ji-Eun Lee;Chul-Won Lee;Seok-Joon Park;Jea-Beom Shin;Hyun-Gi Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.370-376
    • /
    • 2023
  • In the underwater image, it is not clear to distinguish the shape of the target due to underwater noise and low resolution. In addition, as an input of deep learning, underwater images require pre-processing and segmentation must be preceded. Even after pre-processing, the target is not clear, and the performance of detection and identification by deep learning may not be high. Therefore, it is necessary to distinguish and clarify the target. In this study, the importance of target shadows is confirmed in underwater images, object detection and target area acquisition by shadows, and data containing only the shape of targets and shadows without underwater background are generated. We present the process of converting the shadow image into a 3-mode image in which the target is white, the shadow is black, and the background is gray. Through this, it is possible to provide an image that is clearly pre-processed and easily discriminated as an input of deep learning. In addition, if the image processing code using Open Source Computer Vision (OpenCV)Library was used for processing, the processing speed was also suitable for real-time processing.

A Study on Promotion and Improvement of YouTube Music Contents Through the User Evaluation of Card Live ('명함라이브' 사용자 평가를 통한 유튜브 음악 콘텐츠 홍보 및 개선방안 연구)

  • You, Jae-Sun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.105-120
    • /
    • 2020
  • This study explores the process of the actual content production and distribution, by creating a YouTube channel to promote the popular music contents produced by the researcher, which thus reflects the reality where the production of video contents rapidly increases. A YouTube channel titled "Alida Music", of which the focus was to promote indie musicians, was created on February 2019. The contents of 10 indie musicians were produced in one-take live format. The information of the indie musicians was displayed in the form of a screen business card, with their e-mail address and SNS account at the top. Therefore, this promotional design was named "Card Live". Promotional video contents marked with the QR code in the lower right on the screen were produced, along with the promotional phrase "Communicate directly with the artist through the QR code", which allows viewers to watch other contents of the indie musician when they scan the QR code. This research conducted a study on how to improve and promote "Card Live" contents of "Alida Music", which were produced through this process. A group interview targeting five indie musicians, among whom one participant deemed significant was selected to conduct a one-to-one in-depth interview. As a result of the study, the following three conclusions were drawn. First, YouTube was found to be the medium with the greatest influence and highest efficiency at the lowest cost. Second, the evaluation of the participants on "Card Live" were divided into the three categories: need for one-take live, the design elements of "Card Live", and scanning issues of the QR code. Third, there is a need for promotional methods that can effectively utilize the media aspects of YouTube: the channel management issues such as raising public awareness as well as the number of subscribers of "Alida Music" should be resolved and measures to effectively use various media including other SNS should be developed. In terms of its content, it is imperative to recruit diverse performers to make various contents, as well as to come up with ways to link "Card Live" contents with offline. Based on these results, "Card Live" contents should be further revised and complemented in order to provide interesting contents to consumers, which will further develop "Alida Music" as a platform where various musicians and companies meet, thereby inducing contracts with popular music agencies and generating advertising revenues. However, since this study was carried out only with the limited number of participants, future studies should include more participants to bring forth a variety of promotional plans and improvement measures. Also, in the era of consuming contents through smart devices, the fact that some features of "Card Live" were available only on PC, did not fully reflect the characteristics of the times. In the future research, various contents that smartphone users can access and view freely without PC should be produced.

Making Aids of Magnetic Resonacnce Image Susing 3D Printing Technology (3D 프린트를 활용한 자기공명영상검사 보조기구 제작)

  • Choi, Woo jeon;Ye, Soo young;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.403-409
    • /
    • 2016
  • MRI scan is a useful method in the diagnosis of musculoskeletal excellent contrast of the organization. Depending on the patient's musculoskeletal examinations state the type of aids provided the aid is used there is also challenging as well as the costs do not vary. This study was produced by the use of 3D printing technology, an MRI aids. Aids in the production process, then through 3D modeling and then convert stl files using (3D MAX.2014, Fusion360) slicing programs (Cubicreater 2.1ver., Cura 15.4ver) converted to G-code printed on the FDM scheme (Cubicon Style, output was MICRO MAKE). Output is, but in the FDM to evaluate the SNR on the MRI images were compared to the test is the case before use, and then to produce a Water Phantom case of a PLA, ABS, a TPU thickness 3mm, using aids before, It was evaluated in a clinical image after qualitatively. Obtaining an image of SNR Warter Phantom appeared to have been evaluated as T1 NON $123.778{\pm}28.492$, PLA $123.522{\pm}28.373$, ABS $124.461{\pm}25.716$, TPU $124.843{\pm}27.272$. T2 NON $127.421{\pm}26.949$, was rated as PLA $124.501{\pm}27.768$, ABS $128.663{\pm}26.549$, TPU $130.171{\pm}25.998$. The results did not show statistically significant differences. The use of assistive devices before and after images Clinical evaluation method palliative $3.20{\pm}0.88$, $3.95{\pm}0.76$ after using the aids used to aid improved the quality of the image. Production of the auxiliary mechanism using a future 3D printing is expected are thought to be used clinically, it can be an aid making safe and comfortable than the inspection of the patient is an alternative to improve the problems of the aids used in the conventional do.

Clinical Application of Dose Reconstruction Based on Full-Scope Monte Carlo Calculations: Composite Dose Reconstruction on a Deformed Phantom (몬테칼로 계산을 통한 흡수선량 재구성의 임상적 응용: 변형된 팬텀에서의 총제적 선량재구성)

  • Yeo, Inhwan;Xu, Qianyi;Chen, Yan;Jung, Jae Won;Kim, Jong Oh
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.139-142
    • /
    • 2014
  • The purpose of this study was to develop a system of clinical application of reconstructed dose that includes dose reconstruction, reconstructed dose registration between fractions of treatment, and dose-volume-histogram generation and to demonstrate the system on a deformable prostate phantom. To achieve this purpose, a deformable prostate phantom was embedded into a 20 cm-deep and 40 cm-wide water phantom. The phantom was CT scanned and the anatomical models of prostate, seminal vesicles, and rectum were contoured. A coplanar 4-field intensity modulated radiation therapy (IMRT) plan was used for this study. Organ deformation was simulated by inserting a "transrectal" balloon containing 20 ml of water. A new CT scan was obtained and the deformed structures were contoured. Dose responses in phantoms and electronic portal imaging device (EPID) were calculated by using the XVMC Monte Carlo code. The IMRT plan was delivered to the two phantoms and integrated EPID images were respectively acquired. Dose reconstruction was performed on these images using the calculated responses. The deformed phantom was registered to the original phantom using an in-house developed software based on the Demons algorithm. The transfer matrix for each voxel was obtained and used to correlate the two sets of the reconstructed dose to generate a cumulative reconstructed dose on the original phantom. Forwardly calculated planning dose in the original phantom was compared to the cumulative reconstructed dose from EPID in the original phantom. The prescribed 200 cGy isodose lines showed little difference with respect to the "prostate" and "seminal vesicles", but appreciable difference (3%) was observed at the dose level greater than 210 cGy. In the rectum, the reconstructed dose showed lower volume coverage by a few percent than the plan dose in the dose range of 150 to 200 cGy. Through this study, the system of clinical application of reconstructed dose was successfully developed and demonstrated. The organ deformation simulated in this study resulted in small but observable dose changes in the target and critical structure.