• Title/Summary/Keyword: Scaling test

Search Result 430, Processing Time 0.037 seconds

Characteristics of Chloride Penetration with Deicer Types (제설제 종류에 따른 염화물 침투 특성)

  • Choi, Yoon-Suk;Kim, Kang-Rea;Kim, Myung-Yu;Yang, Eun-Ik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.549-552
    • /
    • 2006
  • Deicing salt has been generally used for prevention of a road freezing in winter, and the amount is increasing every year. However, deicing salt may induce the decrease of bond strength, surface scaling, and environmental pollution, etc. The purpose of this paper is to suggest the fundamental data on safety and durability for concrete structures through the estimation of characteristics of chloride penetration with deicer types. According to the test results, as age of concrete is increased, chloride penetration depth is also increased independent of deicer types. However, there is no remarkable difference between deicer types. And when the estimation of chloride diffusion is carried out by immersion test, diffusion coefficient is decreased with ages, and short-term estimation may overestimate the coefficient.

  • PDF

Analysis of Cell Latch-up Effect in SRAM Device (SRAM 소자의 Cell Latch-up 현상 분석)

  • Lee Jun-Ha;Lee Hoong-Joo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.203-205
    • /
    • 2004
  • A soft error rate neutrons is a growing problem for terrestrial integrated circuits with technology scaling. In the acceleration test with high-density neutron beam, a latch-up prohibits accurate estimations of the soft error rate (SER). This paper presents results of analysis for the latch-up characteristics in the circumstance corresponding to the acceleration SER test for SRAM. Simulation results, using a two-dimensional device simulator, show that the deep p-well structure has better latch-up immunity compared to normal twin and triple well structures. In addition, it is more effective to minimize the distance to ground power compared with controlling a path to the $V_{DD}$ power.

  • PDF

On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works. (노천굴착에서 발파진동의 크기를 감량 시키기 위한 정밀파실험식)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.9 no.1
    • /
    • pp.3-13
    • /
    • 1991
  • The cautious blasting works had been used with emulsion explosion electric M/S delay caps. Drill depth was from 3m to 6m with Crawler Drill ${\phi}70mm$ on the calcalious sand stone (soft -modelate -semi hard Rock). The total numbers of test blast were 88. Scale distance were induced 15.52-60.32. It was applied to propagation Law in blasting vibration as follows. Propagtion Law in Blasting Vibration $V=K(\frac{D}{W^b})^n$ were V : Peak partical velocity(cm/sec) D : Distance between explosion and recording sites(m) W : Maximum charge per delay-period of eight milliseconds or more (kg) K : Ground transmission constant, empirically determind on the Rocks, Explosive and drilling pattern ets. b : Charge exponents n : Reduced exponents where the quantity $\frac{D}{W^b}$ is known as the scale distance. Above equation is worked by the U.S Bureau of Mines to determine peak particle velocity. The propagation Law can be catagorized in three groups. Cubic root Scaling charge per delay Square root Scaling of charge per delay Site-specific Scaling of charge Per delay Plots of peak particle velocity versus distoance were made on log-log coordinates. The data are grouped by test and P.P.V. The linear grouping of the data permits their representation by an equation of the form ; $V=K(\frac{D}{W^{\frac{1}{3}})^{-n}$ The value of K(41 or 124) and n(1.41 or 1.66) were determined for each set of data by the method of least squores. Statistical tests showed that a common slope, n, could be used for all data of a given components. Charge and reduction exponents carried out by multiple regressional analysis. It's divided into under loom over loom distance because the frequency is verified by the distance from blast site. Empirical equation of cautious blasting vibration is as follows. Over 30m ------- under l00m ${\cdots\cdots\cdots}{\;}41(D/sqrt[2]{W})^{-1.41}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}A$ Over 100m ${\cdots\cdots\cdots\cdots\cdots}{\;}121(D/sqrt[3]{W})^{-1.66}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}B$ where ; V is peak particle velocity In cm / sec D is distance in m and W, maximLlm charge weight per day in kg K value on the above equation has to be more specified for further understaring about the effect of explosives, Rock strength. And Drilling pattern on the vibration levels, it is necessary to carry out more tests.

  • PDF

A Study on Accelerated Photo-Degradation Test for Lifetime Estimation of Ink-jet Ink (잉크젯 잉크의 수명예측을 위한 광열화 가속시험법에 관한 연구)

  • Koo, Hyun-Jin;Cho, Hang-Won;Ji, Byung-Chul
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.154-162
    • /
    • 2015
  • We have performed accelerated photo-degradation test using a 10-Sun level high irradiance $Weather-Ometer^{(R)}$ (10-Sun Ci5000) in an attempt to study acceleration and correlation between accelerated and service conditions for ink-jet ink. The accelerated test was used to predict lifetimes of ink-jet ink through the calculation of scaling factor for intensity of irradiance and duration of usage combined with estimation of lifetime distribution and inverse power model as a life-stress model. The lifetimes and acceleration factors for foreign and domestic inks were compared with each other. The results showed that the failure mechanisms and life-stress models for ink-jet ink were different among the color of ink which means that we might be in need of further study by color of inks.

Effect of the Variation of Speccfic Gravity and the Addition of Water Repellent Agent on the Physical Properties of Autoclaved Lightweight Concrete (비중의 변화와 발수제 첨가가 경량기포콘크리트의 물성에 미치는 영향)

  • 노재성;황의환;홍성수;이범재
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • The effcct of specific g~avity cont~olled In the .range fiom O.4 to 0.7 by particle size and added amount of A1 powder in the presence or absence of water repellent agent on the physical properties of ALC was examined to evaluate frost resistance and durability. The compressive sttcngth and the tensile strength are increased and independency with water repellent agent when the specific gravity is increased in the range from 0.4 to 0.7. According as the added amount of water repellent agent was increased. frost resistance was improved and absorption ratio was decreased. ALC produced from fine Al powder has a low volume reduction by scaling and a sound apperance after freezing/thawing test and top surface freezing test.

EVALUATION OF SHEAR BEHAVIOR OF LARGE GRANULAR MATERIALS WITH DIFFERENT PARTICLE SIZES BY TRIAXIAL TEST AND NUMERICAL SIMULATION

  • Kim, Bum-Joo;Sagong, Myung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.55-60
    • /
    • 2010
  • Rockfill zones in CFRD consist typically of large granular materials, usually the maximum particle size up to several meters, which makes laboratory testing to determine the mechanical properties of rockfill difficult. Commonly, the design strength of the rockfills is obtained by scaling down the original rockfill materials and performing laboratory strength tests for the reduced size materials. The objective of the present study is to investigate the effect of particle size on the shear behavior and the strength for granular materials. A series of large-scale triaxial tests was conducted on large granular materials with the maximum particle size varying from 20 to 50mm. The test results showed that overall shear behaviors were similar between the samples with different particle sizes while there were slight differences in the magnitudes of the peak shear stress between the samples. In addition, a simulation of the granular material with the max. particle size of 20mm was performed using DEM code, $PFC^{2D}$, and compared with the test results. The deviatoric stress versus strain behaviors of experimental and numerical tests were found to be matched well up to the peak stress state.

  • PDF

Design of Mach-Scale Blade for LCH Main Rotor Wind Tunnel Test (소형민수헬기 주로터 풍동시험을 위한 마하 스케일 블레이드 설계)

  • Kee, YoungJung;Park, JoongYong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.159-166
    • /
    • 2018
  • In this study, the internal structural design, dynamic characteristics and load analyses of the small scaled rotor blade required for LCH(Light Civil Helicopter) main rotor wind tunnel test were carried out. The test is performed to evaluate the aerodynamic performance and noise characteristics of the LCH main rotor system. Therefore, the Mach-scale technique was appled to design the small scaled blade to simulate the equivalent aerodynamic characteristics as the full scale rotor system. It is necessary to increase the rotor speed to maintain the same blade tip speed as the full scale blade. In addition, the blade weight, section stiffness, and natural frequency were scaled according to the Mach-type scaling factor(${\lambda}$). For the design of skin, spar, torsion box, which are the main components of the blade, carbon and glass fiber composite materials were adopted, and composite materials are prepreg types that can be supplied domestically. The KSec2D program was used to evaluate the section stiffness of the blade. Also, structural loads and dynamic characteristics of the Mach scale blade were investigated through the comprehensive rotorcraft analysis program CAMRADII.

The effect of subjective perception and attitude of oral health on the oral health impact profile in industrial accident injury patients (산재환자의 주관적 구강건강상태와 보건태도가 구강건강 영향지수(OHIP)에 미치는 영향)

  • Lee, Hea Shoon;Lee, Kyung Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.757-764
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the oral health impact profile (OHIP) in the industrial accident injury patients, and the effect of subjective perception and attitude of oral health on the oral health-related quality of life in industrial injury patients. Methods : A self-reported questionnaire was filled out by 496 industrial accident injury patients from October 29 to November 30, 2013. Data were analyzed using SPSS ver 20.0 program for chi-square test, t-test, ANOVA, Scheffe test, and Pearson's correlation coefficient. Results : The OHIP-14 was higher oral health-related quality of life in young people, women, highly educated persons, and those having high income and frequent scaling service. The subjective perception and attitude of oral health was closely correlated to the OHIP-14. The factors influencing on the oral health-related quality of life were the subjective perception and attitude toward oral health. Conclusions : It is necessary to emphasize the oral health promotion program for industrial injury patients. The government should pay more attention to the policy for the improvement of the oral health of industrial accident injury patients in the future.

Intentional passive eruption combined with scaling and root planing of teeth with moderate chronic periodontitis and traumatic occlusion

  • Joo, Ji-Young;Kwon, Eun-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.1
    • /
    • pp.20-24
    • /
    • 2014
  • Purpose: The aim of this clinical trial was to explore the impact of intentional passive eruption (IPE) using occlusal reduction on the periodontal parameters of teeth with moderate chronic periodontitis and traumatic occlusion. Methods: This study was performed on 40 teeth from 16 subjects. At baseline, 4 weeks after initial periodontal treatment, and 6 months after IPE, clinical and radiographic examinations were performed. The 20 teeth in the test group underwent IPE using occlusal reduction, whereas the 20 control teeth did not undergone occlusal reduction. Results: All the periodontal parameters were improved by the initial periodontal treatment. The teeth in the test group showed a significantly greater decrease in pocket depth, tooth mobility, and marginal bone loss than did the control group (P<0.05), but there were no significant changes in the attachment level. Significantly greater improvements in all the parameters were observed in the test group after 6 months of IPE compared to 4 weeks after the initial periodontal treatment (P<0.05). Conclusions: Within the limits of this study, performing initial periodontal therapy combined with IPE using occlusal reduction was shown to be very simple and effective. Moreover, IPE would be helpful in improving periodontal parameters.

A Study of Inverse Modeling from Micro Gas Turbine Experimental Test Data (소형 가스터빈 엔진 실험 데이터를 이용한 역모델링 연구)

  • Kong, Chang-Duk;Lim, Se-Myeong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.6
    • /
    • pp.1-7
    • /
    • 2009
  • The gas turbine engine performance is greatly relied on its component performance characteristics. Generally, acquisition of component maps is not easy for engine purchasers because it is an expensive intellectual property of gas turbine engine supplier. In the previous work, the maps were inversely generated from engine performance deck data, but this method is limited to obtain the realistic maps due to calculated performance deck data. Therefore this work proposes newly to generate more realistic compressor map from experimental performance test data. And then a realistic compressor map can be generated form those processed data using the proposed extended scaling method at each rotational speed. Evaluation can be made through comparison between performance analysis results using the performance simulation program including the generated compressor map and on-condition monitoring performance data.