• Title/Summary/Keyword: Scale down test

Search Result 180, Processing Time 0.025 seconds

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

The Development of the Scale for the Elderly's Intention on Home Renovation (노인의 주택개조 의지 측정도구 개발)

  • Jang, Mi Seon;Lee, Yeun Sook
    • 한국노년학
    • /
    • v.34 no.2
    • /
    • pp.215-228
    • /
    • 2014
  • This study aims to develop a scale to measure the elderly's intention on home renovation and to verify its validity. As a methodological study based on the theory of planned behavior, this study provides 26 preliminary items in the pre-test. The first main test, performed to verify the content validity of the developed items, was followed by a second test of construct validity and reliability. As the result of the content validity test targeting experts, some of the original 26 items were excluded, while others were combined for a total of 22. As the result of the construct validity test of the scale, targeting the elderly aged 65 and over, the 22 items were narrowed down to 14 items, excluding the items that were unsuitable for communality and Eigen value. After once more conducting a factor analysis, the items were classified into five factors with a total cumulative variance of 72.5% and a Cronbach's α of 0.75. This study will contribute to the discussion of housing for the elderly by giving force to environmental regeneration activities through facilitating the identification of the home owners' intentions to renovate in order to improve the physical environment in decayed areas at a public level.

UPO: A Chair That Lifts Hips While Standing Up Using the Four-Link Mechanism

  • Kim, Gye-Young;Bae, Hyunjoo;Suk, Hyeon-Jeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.281-287
    • /
    • 2014
  • Objective: The objective of the study is to develop a portable assistance device to help elderly users reduce strain on the knee and leg muscle while the elderly are standing up. Background: The pose of standing up from a chair is a basic movement, but the elderly often have difficulty standing up due to their weak muscles. We focus on designing a solution that helps the elderly reduce physical problems and support them standing up. Method: This study consists of three parts. Part I explores the way to reduce the refrain of leg muscle while standing up from a chair. In the process of structural development, we found that the moment is minimized when user pushes down the armrests due to a decrease in the force acting on the center of mass. In part II, a user test of 20 participants was carried out to rank the order of comfort of two stimuli: the chair with fixed armrests and the chair with the four-link mechanism that we created-in three different ways; (1) to stand up without touching armrests, (2) to stand up by pushing down on fixed armrests, and (3) to stand up by pushing down on armrests and being supported by the mechanism. To examine the statistically significant differences among the rank means, a Friedman test was conducted. In part III, we analyze the results of the user test and interview feedbacks, focusing on establishing a design strategy from UPO and visualizing it in 1:1 scale. Results: In part I, we decided to develop the four-link mechanism. The bottom is lifted up as the link rises. In part II, based on the rank data, we empirically found that UPO was assessed as the most comfortable during the stimuli. The thigh angle is smaller and the bottom of UPO is separated from a seat. In part III, after assessing the results and feedbacks, we created a visualization strategy for UPO: light, friendly, and novel. Conclusion: The portable and non-mechanical UPO comprises a four-link system that lifts the user's hips while standing. It can help users avoid knee and leg muscle strain. Its universal design considers the elderly's difficulties. Application: In a future study, combining light and durable material in UPO is expected to increase its usability. And this study is an opportunity to design various types of standing assistance devices.

The Study of Circuit Model Parameter Generation Using Device Simulation (소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.177-182
    • /
    • 2003
  • In the case of the flash memory, various kinds of transistors and the wide range of operation voltage are necessary to achieve the read/write operations. Therefore, the characteristics of transistors are measured in the silicon for the circuit design, and the test vehicle run must be processed. In this study, an efficient design flow is suggested using TCAD tools. The test vehicle is replaced with well-calibrated TCAD simulation. First, the calibration methodology is introduced and tested for flash memory device. The calibration errors are less than 5% of a full chip operation, which is accepted by the designers. The results of the calibration were used to predict I-V curves and model parameter of the various transistors for the design of flash device.

  • PDF

Taming of large diameter triaxial setup

  • Nair, Asha M.;Madhavi Latha, G.
    • Geomechanics and Engineering
    • /
    • v.4 no.4
    • /
    • pp.251-262
    • /
    • 2012
  • Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

An Experimental Study on Thrust of Ground and High Altitude by Hydrogen Peroxide/Kerosene Engine (과산화수소-케로신 엔진을 이용한 지상 및 고고도 추력에 대한 실험적 연구)

  • Lee, Yang-Suk;Kim, Joong-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.100-106
    • /
    • 2019
  • Ground and high altitude simulated combustion experiments were conducted using a liquid rocket engine with hydrogen peroxide and kerosene as the propellant. A ground and high altitude simulated combustion test facility was constructed by installing a high altitude model diffuser and TMS (Thrust Measuring System) on a vertical combustion test bench. The thrust characteristics according to altitude were investigated using the combustion test equipment. The diffuser was designed on a 1:4.8 scale to verify the characteristics of the high diffusing diffuser and starting pressure. The cold flow tests were conducted using nitrogen gas, and the performance characteristics and starting characteristics of the scale down diffuser were verified. A diffuser and TMS were installed on the vertical combustion test bench, and the thrust correction equations for the system resistance were derived. The thrust correction equations were derived from the step test and vacuum step test before the actual hot firing test. Nozzles with an operating altitude of 10km were designed. Hot firing tests were conducted to analyze the thrust characteristics according to the operating altitude changes. The actual thrust was calculated using each correction equation with the thrust value measured by the TMS.

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.

The Effect of Mental Practice on Increasing Balance and Fall Index & Fall Efficacy Scale of Stroke Patients: Single Subject Experimental Research (상상연습이 뇌졸중 환자의 균형능력과 낙상 위험도 및 낙상 효능감에 미치는 영향: 개별대상자 실험연구)

  • Lee, Jae-Hong;Kim, Su-Kyoung;Choi, Seong-Youl
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.2 no.2
    • /
    • pp.37-49
    • /
    • 2012
  • Objective : The purpose of this study is to investigate the effect of mental practice on increasing balance and fall index & fall efficacy scale of persons with post stroke. Method : As a single subject research design with multiple baseline across individuals, the patients were four stroke patients, employed in this study. The employed program included receiving mental practice, and measuring balance score changes using FRT for 4 weeks, including baseline and intervention periods. The subject's fall danger were measured by Fall Index Test(Tetrax) and Fall Efficacy Scale for balance ability were analyzed. The analyses were performed using visually and Two Standard Deviation Band Method. Result : Using FRT, the participants improved their standing balance. During the intervention periods, Their improvement of balance skills results in decreasing Fall Index increasing Fall Efficacy. Conclusion : As a result of this study, mental practice can be an effective method to improve the balance of stroke patien.

  • PDF

Aeroelastic testing of a self-supported transmission tower under laboratory simulated tornado-like vortices

  • Ezami, Nima;El Damatty, Ashraf;Hamada, Ahmed;Hangan, Horia
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.199-213
    • /
    • 2022
  • The current study investigates the dynamic effects in the tornado-structure response of an aeroelastic self-supported lattice transmission tower model tested under laboratory simulated tornado-like vortices. The aeroelastic model is designed for a geometric scale of 1:65 and tested under scaled down tornadoes in the Wind Engineering, Energy and Environment (WindEEE) Research Institute. The simulated tornadoes have a similar length scale of 1:65 compared to the full-scale. An extensive experimental parametric study is conducted by offsetting the stationary tornado center with respect to the aeroelastic model. Such aeroelastic testing of a transmission tower under laboratory tornadoes is not reported in the literature. A multiaxial load cell is mounted underneath the base plate to measure the base shear forces and overturning moments applied to the model in three perpendicular directions. A three-axis accelerometer is mounted at the level of the second cross-arm to measure response accelerations to evaluate the natural frequencies through a free-vibration test. Radial, tangential, and axial velocity components of the tornado wind field are measured using cobra probes. Sensitivity analyses are conducted to assess the variation of the structural dynamic response associated with the location of the tornado relative to the lattice transmission tower. Three different layouts representing the change in the orientation of the tower model relative to the components of the tornado-induced loads are considered. The structural responses of the aeroelastic model in terms of base shear forces, overturning moments, and lateral accelerations are measured. The results are utilized to understand the dynamic response of self-supported transmission towers to the tornado-induced loads.