• Title/Summary/Keyword: Saving energy

Search Result 2,731, Processing Time 0.042 seconds

Development of Hybrid Excavator for Regeneration of Boom Potential Energy (작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발)

  • Yoon, J.I.;Ahn, K.K.;Truong, D.Q.;Kang, J.M.;Kim, J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF

A Study on Refrigeration warehouse operation for Energy saving technique (에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구)

  • Kim, Dae-Gyun;Kwon, Jung-Dong;Hahm, Nyun-Gun;Lee, Sang-Chip;Kim, Ik-Hwan;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

Independent Metering Valve: A Review of Advances in Hydraulic Machinery

  • Nguyen, Thanh Ha;Do, Tri Cuong;Ahn, Kyoung Kwan
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.54-71
    • /
    • 2020
  • In light of the environmental challenges, energy-saving strategies are currently under investigation in the construction industry. This paper focuses on the energy-saving method used in the hydraulic system based on independent metering (IM) technologies, which can overcome the lost energy at the main control valve of the conventional electrohydraulic servo system. By scientifically arranging the proportional valves, the IM system can individually control the flow rate of the inlet and the outlet ports of the actuators. In addition, the IMV system can be used to effectively regenerate energy under different operating modes, thereby saving more energy than conventional hydraulic systems. Therefore, the IMV system has a great potential to improve the energy efficiency of hydraulic machinery. The overall IMV system, including the configuration, proportional valve, operation mode, and the control strategy is introduced via state-of-the-art hydraulic technologies. Finally, the challenges of IM systems are discussed to provide researchers with directions for future development.

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Energy Reduction Methods using Energy-aware QoS Routing Scheme and Its Characteristics in IP Networks (IP Network에서 Energy-aware QoS Routing에 의한 에너지 감소 방법 및 특성)

  • Han, Chimoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.27-34
    • /
    • 2012
  • Today the energy consumption of ICT networks is about 10% of the worldwide power consumption and will be remarkably increased in the near future. For that reason, the energy saving topics of ICT networks are actually studying in various research institutes. This paper studies the possible energy saving methods assuring the QoS of networks on network level. This paper assumed the energy consumption models according to energy profiles of node and link in IP networks. Especially it formulates the energy problem of a minimum energy consumption with various energy profile models and suggests the methods of energy-aware QoS routing under energy saving and network QoS sustaining condition. It shows the large difference of energy saving according to energy profiles and the possibility of energy saving by using the appropriate energy profile model in the simulation experiment. This paper shows that min_used_path(MP) heuristic of energy-aware QoS routing is the excellent method compared with other heuristic methods as view of reduction ratio of nodes and links and energy saving effect under network QoS sustaining condition. As a result, this paper confirms that the min_used_path(MP) heuristic of energy-aware QoS routing can get energy saving and sustaining of network QoS in IP networks.

Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings (노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교)

  • Lhee, Sang-Choon;Choi, Young-Joon;Kim, Hyun-Ki;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.

Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House (창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로)

  • Kim, Kyung-Ah;Moon, Hyeun-Jun;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

A Study on the Energy Saving and the Reproducibility of highly-efficient Injection Molding Machine (고효율 사출성형기의 에너지 절감 및 성형 재현성 연구)

  • Jeong, C.;Kim, J.S.;Yoon, K.H.;Ahn, H.J.;Hwang, C.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.418-421
    • /
    • 2008
  • Because of steep rise of international energy cost in recent years high efficiency has been emphasized in energy policy. As far as injection molding machine is concerned, hybrid method using hydraulic and electric systems became the key to this energy saving. the energy saving and molding reproducibility of hybrid injection molding process were shown experimentally, power consumption of hybrid machine is 38% as compared with that of hydraulic machine. Furthermore, the molding reproducibility showed between two methods.

  • PDF

Techniques of Management and Energy saving by using power installation (전력사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Hahm, Nyun-Gun;Kim, Dae-Gyun;Lee, Sang-Chip;Oh, Bong-Hwan;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.329-333
    • /
    • 2004
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Energy saving for refrigeration warehouse (냉동냉장창고에 대한 에너지 절약에 대한 연구)

  • Chung, Choon-Byeong;Kim, Dae-Gyun;Kim, Ik-Hwan;Lee, Sang-Chip;Hahm, Nyun-Gun;Jeon, Kee-Young;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.270-274
    • /
    • 2005
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF