• 제목/요약/키워드: Saturation rate

검색결과 806건 처리시간 0.023초

기업의 R&D 구조변화와 정부정책 방향에 대한 소고

  • 송종국;서환주
    • 기술혁신연구
    • /
    • 제11권1호
    • /
    • pp.79-97
    • /
    • 2003
  • R&D expenditure of Korean firms has been increasing drastically since 1980 and occupied 84% of total R&D expenditure in 1994. After 1994, however, the growth rate of industry R&D expenditure has dropped below single digit. R&D concentration rate of upper 20 companies declined from 61.9% in 1999 to 49.8% in 2001. The technology trade balance has diverged by 2.8 billion dollars in 2000 compared to around 0.3 billion dollars in 1985. We find several reasons on declining the industry R&D growth rate in Korea. First, we carefully say there might be an crowding out effect in increasing government R&D investment from Granger causality test between industry R&D and government R&D. Second, the decreasing benefit of tax credit since 1992 on industry R&D expenditure has caused the decrease of industry R&D growth rate. Third, the type of R&D cost becomes to similar to matured countries type of cost, which means the portion of capital expenditure has been decreased since late of 1980s. Therefore, industry R&D growth rate gets to saturation point. We draw several policy implications from the changing structure of business R&D of Korean company. Firstly, to stimulate industry R&D investment Korean government needs to strengthen tax credit policy. Secondly, to induce foreign direct investment Korean government needs to establish technology infrastructures and high quality of manpower. To utilize foreign technology resources Korean government need to introduce global R&D program executed by foreign scientist as an Project Leader.

  • PDF

광합성 미세조류인 Chlorococcum littorale을 이용한 이산화탄소의 생물학적 고정화

  • 김태호;성기돈;이진석;이준엽;오상집;이현용
    • 한국미생물·생명공학회지
    • /
    • 제25권3호
    • /
    • pp.235-239
    • /
    • 1997
  • Chlorococcum littorale has been grown in high $CO_2$ concentrations to utilize $CO_2$ gas in the polluted air. The effect of incident light intensity on the specific growth rate is expressed by a photoinhibition model, showing half- saturation constant, $K_0\;as\;8\;(W/m^2)$ and inhibition constant, Ki as 35 $(W/m^2)$. The maximum specific growth rate was also estimated as 0.095 (1/day) under this condition. This strain maintained the optimum growth rate in 20% of $CO_2$ gas but 50% of input $CO_2$ gas is the maximum concentration considering the economical efficiency. The maximum Specific $CO_2$ consumption rate, $qCO_2$ was measured as 17.48 (mg $CO_2/g$ dry wt./day) in batch cultivation, 11.2 (mg $CO_2/g$ dry wt./day) in fed-batch cultivation and 10.87 (mg $CO_2/g$ dry wt./day) at 0.065 (1/day) of dilution rate in continuous cultivation. The chemical composition of the biomass obtained from this process showed 32.5% of protein, 27.5% of lipid, 16.5% of carbohydrate and ash 11.7%.

  • PDF

광용적맥파를 이용한 실시간 맥박 검출 알고리듬 (A Real Time Heartbeat Rate Estimation Algorithm Using PPG Signals)

  • 김치성;한동석
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.82-87
    • /
    • 2016
  • 광용적맥파(PPG: photoplethysmogram) 신호는 심전도(ECG: electrocardiogram) 신호와 더불어 가장 많이 측정이 되는 생체 신호 중 하나이다. 광용적맥파 신호를 이용하여 측정할 수 있는 정보들은 혈류의 속도, 혈액 중 산소 포화도 등을 측정할 수 있다. 이들을 측정하기 위한 기반 정보는 맥박 정보이다. 광용적맥파 신호로부터 맥박을 측정하기 위하여 동적 잡음이 필수적으로 제거 되어야 한다. 기존 방법은 팔의 움직임을 나타내는 가속도 신호를 이용하여 동적잡음을 제거 하였지만 이는 계산 복잡도를 증가시켜 실시간으로 맥박을 추정하기에 어려움이 있다. 본 논문에서는 광용적맥파 신호만 사용하여 신호를 측정함과 동시에 맥박을 추정해내는 알고리듬을 제안한다.

Nitrate uptake of the red tide dinoflagellate Prorocentrum micans measured using a nutrient repletion method: effect of light intensity

  • Lee, Kyung Ha;Jeong, Hae Jin;Kim, Hye Jeong;Lim, An Suk
    • ALGAE
    • /
    • 제32권2호
    • /
    • pp.139-153
    • /
    • 2017
  • The ability of a red tide species to take up nutrients is a critical factor affecting its red tide dynamics and species competition. Nutrient uptake by red tide species has been conventionally measured by incubating nutrient-depleted cells for a short period at 1 or 2 light intensities. This method may be applicable to certain conditions under which cells remain in oligotrophic water for a long time and high nutrients are suddenly introduced. Thus, a new method should be developed that can be applicable to the conditions under which cells are maintained in eutrophicated waters in healthy conditions and experience light and dark cycles and different light intensities during vertical migration. In this study, a new repletion method reflecting these conditions was developed. The nitrate uptake rates of the red tide dinoflagellate Prorocentrum micans originally maintained in nitrate repletion and depletion conditions as a function of nitrate concentration were measured. With increasing light intensity from 10 to $100{\mu}E\;m^{-2}s^{-1}$, the maximum nitrate uptake rate ($V_{max}$) of P. micans increased from 3.6 to $10.8 pM\;cell^{-1}d^{-1}$ and the half saturation constant ($K_{s-NO3}$) increased from 4.1 to $6.9{\mu}M$. At $20{\mu}E\;m^{-2}s^{-1}$, the $V_{max}$ and $K_{s-NO3}$ of P. micans originally maintained in a nitrate repletion condition were similar to those maintained in a nitrate depletion condition. Thus, differences in cells under nutrient repletion and depletion conditions may not affect $K_{s-NO3}$ and $V_{max}$. Moreover, different light intensities may cause differences in the nitrate uptake of migratory phototrophic dinoflagellates.

최적 입사 광 전력 하에서의 대칭 ESQWs SEED의 비트 전송률 특성 분석 (Bit-Rate Analysis of Various Symmetric ESQWs SEED under Optimized Input Power)

  • 임연섭;최영완
    • 전자공학회논문지D
    • /
    • 제36D권7호
    • /
    • pp.66-79
    • /
    • 1999
  • 본 논문에서는 얕은 양자 우물(extremely shaliow quantum wells, ESQWs)을 사용한 광 쌍안정 대칭형 자기 전광 소자(symmetric self elctrooptic effect device, S-SEED)의 성능에 있어서 높은 입사 광전력의 영향을 조사한다 . 다음과 같은 네 가지 ESQWs S-SEED 구조를 고려하였다. 무 반사 입힘(AR-coated) ESQWs S-SEED, back-to-back ARcoated ESQWs S-SEED, 비대칭 공명구조(AFP) ESQWs S-SEED, back-toback AFP ESQWs S-SEED. 입사 광 전력이 증가함에 따라 On/Off 대조비, On/Off 반사율 차이와 같은 소자성능은 ohmic heating 과 여기자 포화(exciton saturation)의 영향으로 심각하지 않게 저하된다. 한편 소자의 스위칭 속도는 지속적으로 증가하다가 특정 입사 광 전력 하에서 점차 감소하기 시작한다. 직렬 광 연결 시스템(cascading optical interconnection system)에 있어서 소자의 최대 속도 스위칭 동작을 위한 최대 입사 광 전력의 최적화를 바탕으로 0 V와 5 V의 외부 전압 조건에서 양자우물의 수를 변화시키면서 $5{\times}5{\mu}m^2$의 mesa 영역에 대하여 네 가지 ESQWs S-SEED의 시스템 비트 레이트를 모의 실험하고 그 결과를 분석하였다.

  • PDF

Dexmedetomidine과 Pethidine을 이용한 정맥내 진정하에 시행된 악교정수술 후 금속나사제거 (Plate and Screw Removal after Orthognathic Surgery, under Intravenous Sedation with Dexmedetomidine and Pethidine)

  • 강희제;김종렬;김시엽;최태성;장광욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권4호
    • /
    • pp.260-266
    • /
    • 2012
  • Purpose: The purpose of this study is to identify the changes of a physiologic nature and the sedative parameters associated with dexmedetomidine and pethidine, in patients undergoing plate and screw removal surgery, after orthognathic surgery. Methods: Twenty-three patients were sedated with dexmedetomidine and pethidine during plate and screw removal, after orthognathic surgery. An initial loading dose of dexmedetomidine ($1.0{\mu}g/kg$ infused over 10 minutes) was followed by a maintenance dose ($1.0{\mu}g/kg/hr$). Systolic blood pressure, diastolic blood pressure, mean arterial pressure, oxygen saturation, and heart rate were monitored. Perioperative amnesia and anxiety were recorded. Results: Significant changes were found in the blood pressure and heart rate (Freidman test, P<0.05), but not in oxygen saturation (Freidman test, P>0.05). Amnesia during local injection was observed in eight patients (34.8%). Compared with the preoperative anxiety score, the intraoperative anxiety score was decreased. Conclusion: In this study, we found cardiovascular and respiratory stability in intravenous sedation using dexmedetomidine with pethidine, in plate and screw removal, after orthognathic surgery. Furthemore, intravenous sedation using dexmedetomidine with pethidine shows adequate analgesic and sedative effects.

16-APSK 변조 방식의 성능 및 비선형 채널에서의 동작 특성 분석 (Performance and Operating Characteristics Analysis of the 16-APSK Modulation over Nonlinear Channels)

  • 강석헌;김상태;성원진
    • 한국통신학회논문지
    • /
    • 제32권4C호
    • /
    • pp.362-369
    • /
    • 2007
  • APSK(Amplitude Phase Shift Keying) 계열의 디지털 변조 방식은 전송 심볼들이 성상도 상에서 원형으로 분포해 있는 구조적 특성을 갖고 있다. 이러한 구조로 인하여 QAM(Quadrature Amplitude Modulation) 계열의 변조 방식과 비교하여 평균 전력 대비 최대 전력의 크기를 감소시키는 효과를 얻을 수 있으며, 비선형 채널 환경에서 전송 시 성능 열화 정도를 감소시킬 수 있다. 이와 같은 장점으로, APSK 변조 방식은 최근 DVB-S2(Digital Video Broadcasting-Satellite, Version 2)를 포함하는 위성 통신 시스템에서 표준으로 채택되고 있다. 본 논문에서는 일정 크기 이상의 입력 전력 크기에 대해서는 출력 전력 크기가 포화되는 특성을 갖는 채널 모델을 사용하여, 16APSK 변조 방식 적용의 비트 오율 (BER; Bit Error Rate)의 상한 근사식을 유도하고 실제 실험 결과와 비교하여 정확성을 검증한다. 또한 유도식을 활용하여 비트 오율을 최소화시키는 입력 전력의 크기를 결정하였으며, 16APSK 내각원 반지름과 외각원 반지름 비율 및 비선형 채널의 포화 특성에 따른 성능 최적화 방안을 제시한다.

개심술 중 경정맥 산소포화도의 역할 (The Role of Jugular Venous Oxyhemoglobin Saturation Monitoring During Cardic Surgery)

  • 김세연;지대림
    • Journal of Yeungnam Medical Science
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 1994
  • 숭모판 치환술이 예정된 10명의 환자를 대상으로 심폐우회술 동안 발생할 수 있는 뇌산소 요구량과 소모량 사이의 불균형을 조사하기 위해 내경정맥 내의 산소포화도를 체외순환 5분전과 시작후 1분 이내, 저체온 상태가 안정되었을 때와 재가온하여 체온이 $34^{\circ}C$가 되었을 때, 그리고 체외순환 종료 후 15분 이내 등 5단계로 나누어 혈액을 채취하여 평균 동맥압, 체온, 동맥내 이산화탄소 분압, 혈색 소치, PH 등을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 심폐우회술 중 이산화탄소 분압과 혈색소치 및 PH의 특이한 변화는 없었다. 2. 체외순환 직후 체온 및 평균 동맥압과 혈색 소치의 급격한 변화가 있었으나 임상적인 의미는 없었으며, $SjO_2$의 변화도 없었다. 3. 저체온 상태가 안정되었을때 $SjO_2$ 평균치가 72.4%이었으나 체온을 $34^{\circ}C$로 재가온하였을 때 56.1%로 감소하였다. 4. 재가온 시기에 $SjO_2$감소를 예방하기 위해 재가온 속도를 천천히 하고 이산화탄소를 증가시킴으로써 뇌혈류를 증가시키고 마취약제 등을 이용하여 산소에 대한 뇌대사율을 관류지수를 증가시켜야 하겠다.

  • PDF

Use of the Talk Test for Comparison of Exercise Intensity between Aerobic Activities with Treadmill and Bicycle

  • Kwon, Yonghyun;Chang, Jong Sung
    • The Journal of Korean Physical Therapy
    • /
    • 제32권2호
    • /
    • pp.132-136
    • /
    • 2020
  • Purpose: The talk test (TT) is an alternative, self-reported method for prescribing and guiding exercise training in both healthy adults and patients with cardiovascular and pulmonary diseases. This study examined whether the TT is a valid tool for evaluating the exercise intensity during two different types of aerobic activity on a treadmill or stationary bicycle in a healthy population. Methods: A total of ten subjects (six males and four females) who had no medical history related to musculoskeletal, cardiovascular, and pulmonary disorders were enrolled in this study. They were evaluated using the TT, which consisted of three-level of difficulties demanding cardiac loads while performing aerobic activities on a treadmill and bicycle ergometer across two consecutive days in a counterbalanced manner. During the activities, the psychophysiological response markers were collected in terms of the heart rate, oxygen saturation, rating of perceived exertion, and metabolic equivalents. Results: Statistical analyses revealed a significant difference in the between-subject variance regarding the TT level effect (p<0.05). On the other hand, no significant findings were detected on the between-group variance(p>0.05) and the TT level×group interaction (p>0.05). The independent t-test indicated no significant differences in heart rate, oxygen saturation, rating of perceived exertion, and metabolic equivalents at any levels of the TT in the two groups. The TT showed a strong correlation with the rating of perceived exertion. Conclusion: This study showed that the TT is a valid and alternative tool for evaluating the aerobic exercise intensity in a healthy population. In addition, differences in the psychophysiological response markers between two aerobic activities, treadmill and bicycle ergometer, were detected in the same exercise intensity scaled with the TT. The TT can be used to evaluate and prescribe the exercise intensity of aerobic activity in cardiovascular and pulmonary physical therapy.

행동 인지에 따라 사용자 생체 신호를 측정하는 웨어러블 디바이스 소프트웨어 구조 (Software Architecture of a Wearable Device to Measure User's Vital Signal Depending on the Behavior Recognition)

  • 최동진;강순주
    • 한국통신학회논문지
    • /
    • 제41권3호
    • /
    • pp.347-358
    • /
    • 2016
  • 본 논문은 사용자의 행동을 실시간 인지하여 그 행동과 연동하여 생체 신호를 측정 할 수 있는 착용형 단말 소프트웨어 구조를 제안한다. 착용형 단말은 사용자가 일상생활 동안 항상 착용하고 있기 때문에 이러한 장치를 통하여 생체 신호를 측정하는 것은 사용자 행동과 관련된 건강 정보를 얻을 수 있게 해준다. 이 중 산소포화도와 심박수는 사용자가 운동을 하거나 수면을 취하는 동안 변화를 측정하면 호흡기 상태를 진단하는데 사용할 수 있다. 그러나 이런 생체 신호를 생활 중에 측정하는데 있어서 기존의 방법과 같이 연속적으로 측정하는 것은 움직임으로 인한 신호 왜곡 때문에 정확성을 떨어뜨리게 된다. 또 왜곡을 고치기 위해서 복잡한 알고리즘을 적용하는 것도 착용형 단말의 한정적인 자원을 고려하면 적절하지 않다. 따라서 본 논문에서는 연산이 간단한 필터와 가속도 센서를 이용하여 사용자 행동을 먼저 판단하고 그에 연동하여 정확한 생체신호를 측정할 수 있는 착용형 단말 소프트웨어 구조를 제안한다.