• Title/Summary/Keyword: Saturation Temperature

Search Result 936, Processing Time 0.038 seconds

Water Consumption of Twisted Sweet Pepper in Greenhouse (온실에서의 꽈리고추 소비수량)

  • 윤용철;이근후;서원명
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.217-223
    • /
    • 1998
  • This study was performed to figure out water consumption of the twisted sweet pepper in a greenhouse. Obtained results are as follows; 1. The ambient temperature was nearly same as the normal year, while the average air temperature and the relative humidity in the green house were little bit higher than those of the outside condition. The transparency of the greenhouse roof was approximately 50%. The total amount of rainfall during the irrigation period was 1,040㎜ which is 350㎜ higher than 1997 during the same period. 2. In case of pot cultivation, as the saturation ratio was increased, the aeaf area and plant height and yield were also increased. The yield from the field cultivation was higher than the average yield from the pot cultivations which are treated by three levels of saturation ratio. 3. The variation of daily consumptive use of the twisted sweet pepper was very large in it's range. In case of the pot cultivation, as the saturation was increased, the daily and the total consumptive use were increased. 4. The daily consumptive use was strongly correlated with the ambient temperature, while it was weakly correlated with the relative humidity and solar radiation. 5. There were close correlation between plant environment; leaf area, plant height and yield, and consumptive use. As the saturation ratio was increased, the correlation between those plant factors and consumptive use was getting stronger.

  • PDF

Numerical Study of Land/Channel Flow-Field Optimization in Polymer Electrolyte Fuel Cells (PEFCs) (II) - The Effects of Land/Channel Flow-Field on Temperature and Liquid Saturation Distributions - (고분자전해질형연료전지의 가스 채널 최적화를 위한 수치적 연구 (II) - 가스 채널 치수가 온도와 액체포화 분포에 미치는 영향성 -)

  • Ju, Hyun-Chul;Nam, Jin-Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.688-698
    • /
    • 2009
  • Using the multi-dimensional, multi-phase, nonisothermal Polymer Electrolyte Fuel Cell (PEFC) model presented in Part I, the effects of land/channel flow-field on temperature and liquid saturation distributions inside PEFCs are investigated in Part II. The focus is placed on exploring the coupled water transport and heat transfer phenomena within the nonisothermal and two-phase zone existing in the diffusion media (DM) of PEFCs. Numerical simulations are performed varying the land and channel widths and simulation results reveal that the water profile and temperature rise inside PEFCs are considerably altered by changing the land and channel widths, which indicates that oxygen supply and heat removal from the channel to the land regions and liquid water removal from the land toward the gas channels are key factors in determining the water and temperature distributions inside PEFCs. In addition, the adverse liquid saturation gradient along the thru-plane direction is predicted near the land regions by the numerical model, which is due to the vapor-phase diffusion driven by the temperature gradient in the nonisothermal two-phase DM where water evaporates at the hotter catalyst layer, diffuses as a vapor form and then condenses on the cooler land region. Therefore, the vapor phase diffusion exacerbates DM flooding near the land region, while it alleviates DM flooding near the gas channel.

Design of a High Temperature Oven for Measuring the Saturation Intensity of Samarium atom by using Two Wave Mixing

  • Ko, Kwang-Hoon;Moon, Hee-Jong;Park, Hyun-Min;Lee, Jong-Min;Lee, Won-Kyu;Lee, Jai-Hyung;Chang, Joon-Sung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.75-78
    • /
    • 2000
  • We design a high temperature oven for measuring the saturation intensity of the transition line $4f^ 6/6s^{2 7}7F_0 ↔ 4f^6/6s6p $^1$P(J = 1)$ of the samarium atom. We first constructed a high temperature oven to generate the samarium vapor column and study the thermal characteristics of the oven. The oven is able to operate at a temperature up to about 1400 $^{\circ}C$ and the operation is tested by using several metals with high melting points. We describe two wave mixing experiment with the samarium vapor generated in the high temperature oven and obtain the saturation intensity by analyzing the first diffraction signal.

The Effect of Surface Tension on Shear Wave Velocities according to Changes of Temperature and Degree of Saturation (온도와 포화도의 변화에 의한 표면장력이 전단파 속도에 미치는 영향)

  • Park, Jung-Hee;Kang, Min-Gu;Seo, Sun-Young;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.285-293
    • /
    • 2012
  • The surface tension, which is generated in the unsaturated soils, increases the stiffness of the soils. The objective of this study is to estimate the effect of the surface tension, which varies according to the temperature, on the shear wave velocity. Nine specimens, which have the different degree of saturation (0%, 2.5%, 5%, 10%, 20%, 40%, 60%, 80%, 100%), are prepared by using sand-silt mixtures. Experiments are carried out in a nylon cell designed for the measurement of shear waves. A pair of bender elements, which are used for the generation and detection of shear waves, is installed as a cross-hole type. The shear waves are continuously monitored and measured as the temperature of specimens decreases from $15^{\circ}C$ to $1^{\circ}C$. The results show that shear wave velocities of the fully saturated and fully dried specimens change a little bit as the temperatures of specimens decrease. However, the shear wave velocities of the specimens with the degree of saturations of 2.5%, 5%, 10%, 20%, 40%, 60% and 80% continuously increase as temperature decreases from $15^{\circ}C$ to $1^{\circ}C$. Furthermore, a fully saturated specimen is dried at the temperature of $70^{\circ}C$ in order to observe the shear waves according to degree of saturation. The shear wave velocities measured at the temperature of $70^{\circ}C$ are generally lower than those measured at temperature of $15^{\circ}C$. This study demonstrates that the dependence of shear wave velocities on the temperature according to the degree of saturation should be taken into account in both laboratory and field tests.

Effect of Light Intensity, Temperature and $CO_2$ Concentration on Photosynthesis in Hovenia dulcis Thunb. (광도, 온도 및 $CO_2$의 농도가 헛개나무의 광합성에 미치는 영향)

  • Lee, Kang-Soo;Choi, Sun-Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in Hovenia dulcis Thunb. Light compensation point was $2.4\;{\mu}mol\;m^{-2}\;s^{-1}$ and light saturation point was $1033\;{\mu}mol\;m^{-2}\;s^{-1}$. The optimum temperature for photosynthesis was $25^{\circ}C$ at $1000\;{\mu}mol\;m^{-2}\;s^{-1}$ light intensity. $CO_2$ compensation point was 67 vpm and $CO_2$ saturation point was 707 vpm. Transpiration rate was increased to about $2\;mmol\;m^{-2}\;s^{-1}$ with increasing of light intensity to $1750\;{\mu}mol\;m^{-2}\;s^{-1}$ and to above $4\;mmol\;m^{-2}\;s^{-1}$ with increasing of temperature from $18^{\circ}C$ to $36^{\circ}C$. however It was gradually reduced as $CO_2$ concentration increased from 21 vpm to 800 vpm.

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

Electron Tunneling Characteristics of PtSi-nSi Junctions according to Temperature Variations (온도변화에 따른 백금 실리사이드-엔 실리콘 접합의 전자 터널링 특성)

  • 장창덕;이정석;이광우;이용재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.87-91
    • /
    • 1998
  • In this paper, We analyzed the current-voltage characteristics with n-type silicon substrates concentration and temperature variations (Room temperature, 50$^{\circ}C$, 75$^{\circ}C$) in platinum silicide and silicon junction. The electrical parameters of measurement are turn-on voltage, saturation current, ideality factor, barrier height, dynamic resistance in forward bias and reverse breakdown voltage according to variations of junction concentration of substrates and measurement temperature variations. As a result, the forward turn-on voltage, reverse breakdown voltage, barrier height and dynamic resistance were decreased but saturation currents and ideality factor were increased by substrates increased concentration variations in platinum silicide and n-silicon junction. In increased measurement temperature (RT, 50$^{\circ}C$, 75$^{\circ}C$), the extracted electrical parameter values of characteristics were rises by increased temperature variations according to the forward and reverse bias.

  • PDF

A Study on the Characteristics of Evaporative Heat Transfer for Carbon Dioxide in a Horizontal Tube (수평원관 내 이산화탄소의 증발열전달 특성 연구)

  • Cho, E.S.;Yoon, S.H.;Kim, M.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.104-107
    • /
    • 2000
  • Evaporative heat transfer characteristics of carbon dioxide has been investigated. Experiment has been carried out for seamless stainless steel tube with outer diameter of 9.55 mm and inner diameter of 7.75 mm. Direct heating method is used for supplying heat to the refrigerant was uniformly heated by electric current which was applied to the tube wall. The saturation temperature of refrigerant is calculated from the measured saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and heat conduction through the tube wall. Mass Quality of refrigerant was calculated by considering energy balance in the preheater and the test section. Heat fluxes were set at 12, 16, 20, 23, and $27kW/m^2$, mass fluxes were controlled at 212, 318, 424, and $530 kg/m^2s$, and saturation temperature of refrigerant were adjusted at 0, 3.4, 6.7 and $10.5^{\circ}C$. From this study, heat transfer coefficients of carbon dioxide have been provided with respect to quality for several mass fluxes, heat fluxes. Finally, the experimental results in this study are compared with the correaltion by Gungor and Winterton(1987).

  • PDF

Study on the Poling Conditions of PZT Ceramics with $MnO_2$ additive (압전 세라믹 PZT에 첨가된 $MnO_2$가 분극조건에 미치는 영향)

  • Choi, H.I.;Lee, J.H.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.247-250
    • /
    • 1991
  • In this paper, we have investigated the poling conditons depending upon the electric field and temperature for PZT ceramics with various stoichiometry prepared by wet direct method, and $MnO_2$ dopant. The electric field required for saturation polarization was plotted against temperature $(1,000/T^{\circ}K)$ so that the required field could be estimated at any given temperature by measuring the charge displaced during poling. From this curve it should be possible to predict the field required to produce maximum domain switching at temperature below the Curie temperature, when $MnO_2$ dopant was added to the PZT ceramics, the electric field required for saturation polarization was lowered than that of undoped PZT samples.

  • PDF

Correlation between Phytoplankton Dynamics and Water Quality in Paldang Reservoir (팔당호에서 식물플랑크톤 군집 동태와 수질과의 상관성)

  • Han, Myung-Soo;Jheong, Weon-Hwa;Park, Jun-Dae;Kim, Jong-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.2 s.112
    • /
    • pp.217-224
    • /
    • 2005
  • This study was aimed to analyze the long-term fluctuation of water quality and phytoplankton dynamics of Paldang reservoir in Korea and to assess the relationship between algal bloom patterns and hydrological, limnological data. Diatoms in Paldang reservoir occurred continuously through the year. Blue- green algae occurred during the summer season (from June to Sept.), and the highest count was observed in July. Occurrence pattern of green algae was similar to that of blue-green algae. The rest of algae contained a lot of Cryptomonas spp. whose concentration was high from May to Aug. Dominant algal genera (>>7,000 cells $mL^{-1}$) in Paldang reservoir were Aulacoseira, Cyclotella, Microcystis, and Cryptomonas spp. Microcystis and Anabaena occurred during the summer season. Many different green algal genera were found in Paldang reservoir but their abundances were very low. There were some significant correlations (r>0.3, p<0.05) between algal taxa and water quality; diatoms and water temperature, TP:blue-green algae and water temperature, pH, DO saturation, COD, TP; green algae and water temperature, pH, DO saturation, COD, SS, TP. Furthermore, algal genera and water quality was significantly correlated (r>0.3, p<0.05) ; Aulacoseira and TN, TP; Anabaena and water temperature, DO saturation, COD, TP : Microcystisand water temperature, pH, DO saturation, TP; Coelastrum and COD, SS; Scenedesmus and water temperature, COD, TN, TP; Cryptomonas and DO saturation, TN. In Paldang reservoir, the water temperature had relatively big effect on blue-green algal bloom that was also dependant upon its hydrologic condition.