• 제목/요약/키워드: Saturation Temperature

검색결과 936건 처리시간 0.026초

Nucleate Pool Boiling of a Structured Enhanced Tube Used in a Flooded Refrigerant Evaporator

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Choi, Kuk-Kwang
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.23-28
    • /
    • 2000
  • In this study, pool boiling performance of a structured enhanced tube for a flooded refrigerant evaporator was experimentally investigated. Tests were performed for three different refrigerants(R-11, R-123, R-l34a). Compared with the heat transfer coefficients of the smooth tube, the heat transfer coefficients of the enhanced tube were 6.6 times larger for R-11, 6.0 times larger for R-123 and 3.5 times larger for R-l34a, which are comparable with the performance of foreign products. The heat transfer coefficients of R-l34a was higher than those of R-11 or R-123, both for the enhanced tube and for the smooth tube. At 4.4$^\circ$C saturation temperature, however, the heat transfer coefficients of R-l34a was approximately the same as those of R-11. The effect of the saturation pressure on the boiling performance was similar to that of the smooth tube-the heat transfer coefficient increased as the saturation pressure increased.

  • PDF

터보냉동기용 만액식 증발기에 사용되는 성형가공관의 풀비등 성능 (Pool boiling performance of an enhanced tube used in flooded refrigerant evaporator for turbo-refrigerator)

  • 김태형;김내현
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.808-814
    • /
    • 1999
  • Pool boiling performance of a metal-formed enhanced tube for a flooded refrigerant evaporator was experimentally investigated. Tests were performed for three different refrigerants(R-11, R-123, R-l34a), at two different saturation temperatures $4.4^{\circ}C \;and \;26.7^{\circ}C$ .Heat flux was varied from 10㎾/$m^2\;to\ 50㎾/$m^2$. Compared with the heat transfer coefficients of the smooth tube, the heat transfer coefficients of the enhanced tube were 6.6 times higher for R-11, 6.0 tines higher for R-123 and 3.5 times higher for R-l34a. The enhancements are comparable with those of foreign products. The heat transfer coefficients of R-l34a were higher than those of R-11 and R-123, either for the enhanced tube or for the smooth tube. At $4.4^{\circ}Csaturation temperature, however, the heat transfer coefficients of R-l34a were approximately the same as those of R-11, The effect of the saturation pressure on the boiling performance was similar to that of the smooth tube - the heat transfer coefficient increases as the saturation pressure increases.

  • PDF

일광에 의해 야기되는 '부유' 단감의 저장 중 과피흑변 (Sunlight Causes Skin Blackening in 'Fuyu' Persimmon Fruits during Storage)

  • 최성진
    • 원예과학기술지
    • /
    • 제33권1호
    • /
    • pp.55-60
    • /
    • 2015
  • 과피흑변은 '부유' 단감(Diospyros kaki, 'Fuyu') 과실의 저장 중에 발생하는 주요 생리적 장해의 하나이다. 부유 과실의 과피에서 페놀화합물의 함량, PPO와 POD의 활성, 지질 포화도를 분석하였다. 페놀화합물은 일광의 방향에 따라 과피에 불균등하게 분포하였는데, 일광 노출면에 축적량이 가장 많았고 그 반대면에서는 가장 적었다. 그러나 수관 내부의 음지 가지에서 수확한 과실의 경우 페놀화합물은 과피에 비교적 고르게 분포되어 있었다. PPO와 POD의 활성 또한 과피에서 고르지 않았으나, 이는 과피흑변이 발생한 과실에서만 그러하였으며, 흑변 부위는 PPO 활성은 가장 높고 POD 활성은 가장 낮았다. 수확 시에 일광면에 표식을 한 과실을 저온에 저장하였을 때, 저장 중 과피흑변의 증상인 운형 흑반은 정확히 표식 부위에 발생하였다. 게다가, 일광면은 높은 지질포화도를 보였는데, 이는 일광에 의해 야기된 고온에 대한 적응을 의미한다. 따라서 이러한 결과로 미루어 볼 때, 부유 과실의 과피흑변 장해는 일광에 노출된 과실의 고온 순화 과피 조직에서 나타나는 저온장해 증상의 일종인 것으로 간주할 수 있을 것이다.

수온과 저산소에 따른 조피볼락(Sebastes schlegeli)의 호흡대사와 혈액성상의 변화 (Changes in metabolic rate and hematological parameters of black rockfish (Sebastes schlegeli) in relation to temperature and hypoxia)

  • 김흥윤
    • 한국어병학회지
    • /
    • 제34권2호
    • /
    • pp.213-224
    • /
    • 2021
  • 본 연구는 수온 15, 20 및 25℃에서 조피볼락(Sebastes schlegeli)을 점진적인 저산소 조건에 노출시켜 호흡 대사율이 표준대사율(SMR) 이하로 감소하는 산소포화도, Scrit를 평가하고, 수온별 Scrit 에 4시간 노출 후 혈액 성상의 변화를 조사하기 위하여 실시하였다. 수온 15, 20, 25℃에서 normoxic SMR은 각각 116.5±5.5, 188.6±4.2 및 237.4±6.8 mg O2/kg/hr이었고, 호흡계수(Q10)는 15-20℃ 구간에서는 2.62, 20-25℃에서는 1.58, 그리고 전 수온 범위의 15-25℃에서는 2.04였다. 수온 15, 20 및 25℃에서 Scrit는 각각 22.1±1.2, 30.6±1.5 및 41.9±1.4 %였다. 수온별 Scrit에 4시간 노출 후 혈액 Ht와 Hb 및 혈장 cortisol, glucose, 전해질(Na+, K+, Cl-)과 삼투질 농도는 모든 수온에서 normoxic water의 대조구에 비하여 유의하게 높았다. 수온 15, 20, 25℃의 normoxic water에서는 Ht, Hb 및 혈장 glucose 농도는 15℃에 비하여 20℃와 25℃에서, 혈장 cortisol, 전해질 및 삼투질 농도는 25℃에서 유의하게 높았다. 수온별 Scrit의 저산소에 노출된 조피볼락은 수온이 높을수록 저산소에 의한 어체의 생리적 스트레스는 가중되는 것으로 나타났다.

다층 박막의 온도상승에 대한 마이크로 트라이볼로지적 조사 (Micro-Tribological Investigation for Temperature Rise in Multi-layered Thin Films)

  • 김준현;신경호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.760-765
    • /
    • 2000
  • The study deals with the development of a computational procedure for evaluating the temperature rise in dry and lubricated multi-layered contacts of head/disk interface. A transient computational model with a transformed rectangular computational domain is utilized. A model and a computational method for micro-contact with sub-lubricated zone, including friction heat generation, have been presented. The model was applied, taking full account of the changes in contact area and contact load due to frictional heating. The computational distribution of temperature is obtained with the analytical findings for various composition and contact conditions. Especially, a rapid rise ($220^{\circ}C$ or above) in read head temperature lese to a saturation in the influence of a thermal spike on signal performance. This general class of problems can be treated provided that heat generation distribution and layer properties are known.

  • PDF

Evaluation of Water Suction for Compacted Bentonite Buffer Under Elevated Temperature Conditions

  • Yoon, Seok;Lee, Deuk-Hwan;Cho, Won-Jin;Lee, Changsoo;Cho, Dong-Keun
    • 방사성폐기물학회지
    • /
    • 제20권2호
    • /
    • pp.185-192
    • /
    • 2022
  • A compacted bentonite buffer is a major component of engineered barrier systems, which are designed for the disposal of high-level radioactive waste. In most countries, the target temperature required to maintain safe functioning is below 100℃. If the target temperature of the compacted bentonite buffer can be increased above 100℃, the disposal area can be dramatically reduced. To increase the target temperature of the buffer, it is necessary to investigate its properties at temperatures above 100℃. Although some studies have investigated thermal-hydraulic properties above 100℃, few have evaluated the water suction of compacted bentonite. This study addresses that knowledge gap by evaluating the water suction variation for compacted Korean bentonite in the 25-150℃ range, with initial saturations of 0 and 0.22 under constant saturation conditions. We found that water suction decreased by 5-20% for a temperature increase of 100-150℃.

Spark Plasma Sintering Behaviors of M-type Barium Hexaferrite Nano Powders

  • Jung, Im Doo;Kim, Youngmoo;Hong, Yang-Ki;Park, Seong Jin
    • 한국분말재료학회지
    • /
    • 제21권4호
    • /
    • pp.256-259
    • /
    • 2014
  • A magnetic powder, M-type barium hexaferrite (BaFe12O19), was consolidated with the spark plasma sintering process. Three different holding temperatures, $850^{\circ}C$, $875^{\circ}C$ and $900^{\circ}C$ were applied to the spark plasma sintering process with the same holding times, heating rates and compaction pressure of 30 MPa. The relative density was measured simultaneously with spark plasma sintering and the convergent relative density after cooling was found to be proportional to the holding temperature. The full relative density was obtained at $900^{\circ}C$ and the total sintering time was only 33.3 min, which was much less than the conventional furnace sintering method. The higher holding temperature also led to the higher saturation magnetic moment (${\sigma}_s$) and the higher coercivity ($H_c$) in the vibrating sample magnetometer measurement. The saturation magnetic moment (${\sigma}_s$) and the coercivity ($H_c$) obtained at $900^{\circ}C$ were 56.3 emu/g and 541.5 Oe for each.

Modified Ammonia Removal Model Based on Equilibrium and Mass Transfer Principles

  • Shanableh, A.;Imteaz, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.1920-1926
    • /
    • 2010
  • Yoon et $al.^1$ presented an approximate mathmatical model to describe ammonia removal from an experimental batch reactor system with gaseous headspace. The development of the model was initially based on assuming instantaneous equilibrium between ammonia in the aqueous and gas phases. In the model, a "saturation factor, $\beta$" was defined as a constant and used to check whether the equilibrium assumption was appropriate. The authors used the trends established by the estimated $\beta$ values to conclude that the equilibrium assumption was not valid. The authors presented valuable experimental results obtained using a carefully designed system and the model used to analyze the results accounted for the following effects: speciation of ammonia between $NH_3$ and $NH^+_4$ as a function of pH; temperature dependence of the reactions constants; and air flow rate. In this article, an alternative model based on the exact solution of the governing mass-balance differential equations was developed and used to describe ammonia removal without relying on the use of the saturation factor. The modified model was also extended to mathematically describe the pH dependence of the ammonia removal rate, in addition to accounting for the speciation of ammonia, temperature dependence of reactions constants, and air flow rate. The modified model was used to extend the analysis of the original experimental data presented by Yoon et $al.^1$ and the results matched the theory in an excellent manner.

수평관내 이산화탄소의 증발 압력강하 (Evaporation pressure drop of $CO_2$ in a horizontal tube)

  • 이동건;손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.552-559
    • /
    • 2005
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation pressure drop of $CO_2$ are highly dependent on the vapor qualify, heat flux and saturation temperature. The evaporation pressure drop of $CO_2$ is very lower than that of R-22. In comparison with test results and existing correlations. the best fit of the present experimental data is obtained with the correlation of Choi et al. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

셀 앤 플레이트 열 교환기에서의 R-410A 증발열전달에 관한 실험적 연구 (Experimental Study on R-410A Evaporation Heat Transfer Characteristics in Shell and Plate Heat Exchanger)

  • 김인관;김영수;박재홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.49-59
    • /
    • 2005
  • The evaporation heat transfer experiments are conducted with the shell and plate heat exchanger (S&PHE) without oil in the refrigerant loop using R-410A. An experimental refrigerant loop has been established to measure the evaporation heat transfer coefficient h. of R-410A in a vertical S&PHE. Two vertical counter flow channels were formed in the S&PHE by three plates haying a corrugated trapezoid shape of a $45^{\circ}C$ chevron angle. UP flow of the boiling R-410A in one channel receives heat from the hot down flow of water in the other channel The effects of the refrigerant mass flux. average heat flux. refrigerant saturation temperature and vapor qualify are explored in detail. Similar to the case of a plate heat exchanger. even at a very low Reynolds number, the flow in the S&PHE remains turbulent. The Present data shows that the evaporation heat transfer coefficients of R-410A increased with the vapor qualify. The results indicate a rise in the refrigerant mass flux caused an increase in the h.. Raising the imposed wall heat flux is found to slightly improve h., while h, is found to be lower at a higher refrigerant saturation temperature. Based on the present data. empirical correlation of the evaporation heat transfer coefficient is proposed.