• 제목/요약/키워드: Saturation Phenomenon

검색결과 112건 처리시간 0.023초

간호사의 직장 내 괴롭힘 경험에 관한 근거이론 연구 (A Grounded Theory Approach on Nurses' Experience with Workplace Bullying)

  • 강지연;윤선영
    • 대한간호학회지
    • /
    • 제46권2호
    • /
    • pp.226-237
    • /
    • 2016
  • Purpose: The purpose of this qualitative study was to explore the workplace bullying experience of Korean nurses. Methods: Participants were twenty current or former hospital nurses who had experienced workplace bullying. Data were collected through focus group and individual in-depth interviews from February to May, 2015. Theoretical sampling method was applied to the point of theoretical saturation. Transcribed interview contents were analyzed using Corbin and Strauss's grounded theory method. Results: A total of 110 concepts, 48 sub-categories, and 17 categories were identified through the open coding process. As a result of axial coding based on the paradigm model, the central phenomenon of nurses' workplace bullying experience was revealed as 'teaching that has become bullying', and the core category was extracted as 'surviving in love-hate teaching' consisting of a four-step process: confronting reality, trial and error, relationship formation, and settlement. The relationship formation was considered to be the key phase to proceed to the positive settlement phase, and the participants utilized various strategies such as having an open mind, developing human relationships, understanding each other in this phase. Conclusion: The in-depth understanding of the workplace bullying experience has highlighted the importance of effective communication for cultivating desirable human relationships between nurses.

비선형 타이어모델을 이용한 4WS 자동차의 주행특성 해석 (Dynamic Characteristics Analysis of Four Wheel Steering Vehicles Using Nonlinear Tire Model)

  • 김형내;김석일;김동룡;김건상
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.110-119
    • /
    • 1997
  • Four wheel steering(4WS) systems which can control the lateral and yaw motions of vehicles by steering front and rear wheels simultaneously, have been regarded as effective for improving the stability and handing performance of vehicles. However, since the 4WS systems depend only on the lateral force of tire, they have some limitation due to the nonlinear characteristics of tire related with the saturation phenomenon of lateral force to the slip angle of tire in a near-limit-performance maneuvering range. In this study, in other to evaluate the effect of nonlinear characteristics of tire on the dynamic performance of vehicles, a new concept for driving the cornering stiffness of nonlinear tire by using the "Magic Formula" tire model is proposed. In addition, the nonlinear 4WS vehicle model is constructed based on the proposed cornering stiffness of nonlinear tire. It is noted from simulation that the nonlinear characteristics of tire affect greatly on the 4WS vehicle performance.rformance.

  • PDF

PLD 기법에 의한 $Na_0.5$$K_0.5$$NbO_3$ 휘발성 물질의 박막 제작 및 XRD에 의한 c축 배향성 확인에 관한 연구 (A Study on the Fabrication $Na_0.5$$K_0.5$$NbO_3$ Volatile Material Thin Film by Pulsed Laser Deposition and he Confirmation of C-axis Orientation by X-ray Diffraction)

  • 최원석;김장용;장철순;문병무
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.269-273
    • /
    • 2001
  • W fabricated thin film using Na$_{0.5}$K$_{0.5}$NbO$_3$ volatile material by pulsed laser deposition (PLD) and studied characterization from EM, XRD, P-E. The density and scale of droplet, which is the defect of PLD, was investigated by SEM but large droplet was not found. The degree of assemble oriented C-axis measured with X-ray diffraction suggests that this film oriented C-axis achieved by $\theta$-2$\theta$ scan and rocking curves shows good self-assemble phenomenon, finally $\phi$-scan does that all of the four directions of the lattice in film equals to those of substrate. P-E hysteresis loop shows residual remnant polarization or saturation polarization value, but it is applicable to memories.ies.

  • PDF

자기매계변수 연성을 갖는 응답의 통계적 특성 (Stochastic Response of a System with Autoparametric Coupling)

  • 조덕상;김영종
    • 한국전산구조공학회논문집
    • /
    • 제13권4호
    • /
    • pp.387-394
    • /
    • 2000
  • 본 연구에서는 광대역 불규칙가진력을 받는 자기매계변수계의 모드상호작용을 고찰하였다. 고찰대상 모델은 매우 흔한 추조물의 형태인 내부공진을 갖는 자기매계변수 동흡진기이다. Gaussian closure 방법에 의하여 계의 불규칙 응답을 나타내는 통적 모멘트방정식은 1차 및 2차 모멘트로 구성된 자율 상미분방적식으로 줄여진다. 계의 평형해와 평형해의 안정성측면에서 계의 응답이 조사되었다. 참고문헌 [18]과 [20]에서 보고된 발견한 감쇠가 안정성을 축소하기도 한다라는 이 효과는 본 연구에서 발견할 수 없었다. 또한 확정적 비선형계에 존재하는 포화현상은 발견되지 않았다.

  • PDF

LIF를 이용한 Hg-Ar 플라즈마 특성 평가 (Evaluation of Plasma Characteristics for Hg-Ar Using LIF)

  • 문종대
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.79-83
    • /
    • 2008
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength. change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\to}6^3P_2$) were larger than 404.8nm ($6^3S_1{\to}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구 (Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure)

  • 홍성덕;천세영;김세윤;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

The analysis of neutral particle in Mercury discharge lamp

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2421-2423
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm $(6^3S_1{\rightarrow }6^3P_2)$ were larger than 404.8nm $(6^3S_1{\rightarrow}6^3P_1)$. According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

밀폐형 2상 열사이폰의 Pool 내부 Pulse Boiling에 관한 연구 (A study on the pulse boiling occurring inside the liquid pool of a closed two-phase thermosyphon)

  • 김철주;문석환;강환국
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1254-1261
    • /
    • 1997
  • Pulse boiling, the unsteady periodic boiling phenomenon appearing in the evaporator of thermosyphons was investigated by many researchers. In the present study investigations were conducted to examine the evolution of flow patterns at the evaporator, and changes in thermodynamic state that each of liquid pool and vapor experiences through 1 cycle of pulse boiling process. For wall and liquid pool the degree of superheat for the onset of nucleation was examined. It revealed that the degree of superheat increased with the increase of pulse period, reaching to 16.5 deg.C and 23 deg.C for liquid pool and evaporator wall respectively at .tau.=80 sec. The data on flow patterns obtained through series of operation tests were plotted in the coordinates of heat flux and vapor pressure to get a regime map. Further this map could be used to figure out the conditions of pulse boiling for a thermosyphon.

Heat Transfer Characteristics of an Internally-Heated Annulus Cooled with R-134a Near the Critical Pressure

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.403-414
    • /
    • 2004
  • An experimental study of heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) tests, and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with increase of the system pressure for fixed inlet mass flux and subcooling. The CHF falls sharply at about 3.8 MPa and shows a trend towards converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall, because the CHF occurs at remarkably low power levels. In the pressure reduction transients, as soon as the pressure passes below the critical pressure from the supercritical pressure, the wall temperatures rise rapidly up to very high values due to the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, and then tends to decrease gradually.