• Title/Summary/Keyword: Saturation Efficiency

Search Result 297, Processing Time 0.031 seconds

Efficiency Evaluation of PMASynRM versus SynRM Using a Coupled Finite Element Method and Preisach Modeling

  • Lee, Jung-Ho;Lee, Il-Kyo
    • Journal of Magnetics
    • /
    • v.15 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • This paper deals with the efficiency evaluations in a synchronous reluctance motor (SynRM) versus a permanent magnet assisted SynRM (PMASynRM), using a coupled transient finite element method (FEM) and Preisach modeling, which is presented to analyze the characteristics under the effects of saturation and hysteresis loss. We herein focus on the efficiency evaluation relative to hysteresis loss and copper loss on the basis of load conditions in a SynRM and PMASynRM. Computer simulation and experimental results for the efficiency, using a dynamometer, show the propriety of the proposed method and the high performance of the PMASynRM.

Proposal of Potted Inductor with Enhanced Thermal Transfer for High Power Boost Converter in HEVs

  • You, Bong-Gi;Ko, Jeong-Min;Kim, Jun-Hyung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1075-1080
    • /
    • 2015
  • A hybrid electric vehicle (HEV) powertrain has more than one energy source including a high-voltage electric battery. However, for a high voltage electric battery, the average current is relatively low for a given power level. Introduced to increase the voltage of a HEV battery, a compact, high-efficiency boost converter, sometimes called a step-up converter, is a dc-dc converter with an output voltage greater than its input voltage. The inductor occupies more than 30% of the total converter volume making it difficult to get high power density. The inductor should have the characteristics of good thermal stability, low weight, low losses and low EMI. In this paper, Mega Flux® was selected as the core material among potential core candidates. Different structured inductors with Mega Flux® were fabricated to compare the performance between the conventional air cooled and proposed potting structure. The proposed inductor has reduced the weight by 75% from 8.8kg to 2.18kg and the power density was increased from 15.6W/cc to 56.4W/cc compared with conventional inductor. To optimize the performance of proposed inductor, the potting materials with various thermal conductivities were investigated. Silicone with alumina was chosen as potting materials due to the high thermo-stable properties. The proposed inductors used potting material with thermal conductivities of 0.7W/m·K, 1.0W/m·K and 1.6W/m·K to analyze the thermal performance. Simulations of the proposed inductor were fulfilled in terms of magnetic flux saturation, leakage flux and temperature rise. The temperature rise and power efficiency were measured with the 40kW boost converter. Experimental results show that the proposed inductor reached the temperature saturation of 107℃ in 20 minutes. On the other hand, the temperature of conventional inductor rose by 138℃ without saturation. And the effect of thermal conductivity was verified as the highest thermal conductivity of potting materials leads to the lowest temperature saturations.

Study on Switching Angle Characteristics for Driving Performance Improvement of SRM Drive (SRM 드라이브의 운전성능 향상을 위한 스위칭각 특성에 관한 연구)

  • 오석규;최대완;안진우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.506-513
    • /
    • 2001
  • The torque of an SRM depends on the phase current and derivative of inductance. But an SRM is difficult to control the desired torques because of saturation in magnetic circuit An SRM is controlled by parameters of input voltage, and switch on , off angle The switch on off angles of an SRM regulate the magnitude and shape of current waveform and decide the magnitude and shape of torque This paper proposes an the optimization control scheme by adjusting both the switch on an switch off angle . The switch off angles are decided by reference of efficiency using simulation and experiments. The switch on angles are decided by load torque , And the dwell angles are controlled for torque control and speed control using GA-neural network which is used to simulated the reasonable switching angle.

  • PDF

Saturation curves for chemical coagulation of wastewater treatment (화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선)

  • Ryu, Jae-Na;Oh, Je-Ill;Lee, Kyeoung-Jong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

Characteristics of Electrokinetic Remediation of Unsaturated Soil I : Experimental Study (불포화토의 동전기 정화 특성 I : 실험적 연구)

  • Kim, Byung Il;Han, Sang Jae;Kim, Soo Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1C
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study is to experimentally analysis the eletrokinetic phenomena and remediation characteristics developed during the application of electrokinetic remediation technique to unsaturated soils contaminated by heavy metals. In the laboratory a series of column tests are performed on degree of saturation for shooting range soil. The test results indicated that Pb is mainly removed under unsaturated conditions by electromigration within diffuse double layer, and if the initial containment concentration is below cation exchange capacity and equals to adsorption per unit soil solid weight, the remedial efficiency decreases with the decreasing of transport efficiency due to the changes in the degree of saturation in the electric gradient of 1V/cm.

Development of the Ka-band 20watt SSPA (Solid State Power Amplifier) Using a Spatial Combiner (공간결합기를 이용한 Ka대역 20W급 SSPA 개발)

  • Choi, Young-Rak;Lee, Jong-Woo;Lee, Su-Hyun;An, Se-Hwan;Lee, Man-Hee;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.231-238
    • /
    • 2019
  • In this paper, we have studied how to improve the amplifiers efficiency by minimizing the combining loss when several unit power amplifiers are combined to obtain high output power. Specifically, we have developed Ka-band Spatial Combining Amplifier. The fabricated Spatial Combining Amplifier is a Ka-band 20W class SSPA, which uses a 5W class unit amplifier module 8EA designed using a GaN bare die. We also combined The unit amplifier module using 8-way spatial divider and combiner with a hybrid radial structure. The output combining loss of the fabricated spatial coupler is about 0.334dB, which is about 92.6% efficiency. In this paper, we developed a Spatial Combining Amplifier with a maximum saturation output of 10W and a power addition efficiency of over 15%. As a result, we achieved the maximum saturation output of 30W and the power addition efficiency of 19%.

Copper Loss and Torque Ripple Minimization in Switched Reluctance Motors Considering Nonlinear and Magnetic Saturation Effects

  • Dowlatshahi, Milad;Saghaiannejad, Sayed Morteza;Ahn, Jin-Woo;Moallem, Mehdi
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.351-361
    • /
    • 2014
  • The discrete torque generation mechanism and inherently nonlinear magnetic characterization of switched reluctance motors lead to unacceptable torque ripples and limit the application of these motors. In this study, a phase current profiling technique and torque sharing function are proposed in consideration of magnetic saturation effects and by minimizing power loss in the commutation area between the adjacent phases. Constant torque trajectories are considered in incoming and outgoing phase current planes based on nonlinear T-i-theta curves obtained from experimental measurements. Optimum points on constant torque trajectories are selected by improving drive efficiency and minimizing copper loss in each rotor position. A novel analytic invertible function is introduced to express phase torque based on rotor position and its corresponding phase current. The optimization problem is solved by the proposed torque function, and optimum torque sharing functions are derived. A modification method is also introduced to enhance the torque ripple-free region based on simple logic rules. Compared with conventional torque sharing functions, the resultant reference current from the proposed method has less peak and effective values and exhibits lower copper loss. Experimental and simulation results from a four-phase 4 KW 8/6 SRM validate the effectiveness of the proposed method.

Efficiency Evaluation of PMASynRM vs. SynRM Using Coupling FEM & Preisach Modeling (유한요소법과 프라이자흐모델이 결합하는 해석기법을 이용한 PMASynRM과 SynRM의 효율특성 비교)

  • Yun, Tae-Won;Kim, Young-Hyun;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.756_757
    • /
    • 2009
  • This paper deal with the efficiency evaluations in a Synchronous reluctance motor(SynRM) Vs. PMASynRM using a coupled transient finite element methed(FEM) and preisach modeling, which is presented to analyze the characteristics under the effect of saturation and hysteresis loss. The focus of this paper is the efficiency evaluation relative to hysteresis loss, copper loss, etc. on the basis of load condition in a SynRM and PMASynRM. Computer simulation and experimental result for the efficiency using dynamometer shoe the propriety of the proposed method.

  • PDF

Loss Analysis and Efficiency Evaluations of Synchronous Reluctance Motor Using Coupled FEM & Preisach Modelling (유한요소법과 프라이자흐 모델을 이용한 SynRM의 손실해석과 효율평가)

  • Cho, Yong-Hyun;Lee, Il-Kyo;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.718_719
    • /
    • 2009
  • This paper deals with the loss analysis and efficiency evaluations in a synchronous reluctance motor (SynRM) using a coupled transient finite element method (FEM) and Preisach modeling, which is presented to analyze the characteristics under the effect of saturation and hysteresis loss. The focus of this paper is the efficiency evaluation relative to hysteresis loss, copper loss, etc. on the basis of speed, load condition in a SynRM. Computer simulation and experimental result for the efficiency using dynamometer show the propriety of the proposed method.

  • PDF

Efficiency Evaluations of Synchronous Reluctance Motor Using Coupled FEM & Preisach Modelling (프라이자흐 모델이 결합된 유한요소해석 및 실험을 통한 동기형 릴럭턴스 전동키의 효율 특성 평가)

  • Lee, D.D.;Lee, M.M.;Sim, J.M.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.49-51
    • /
    • 2002
  • This paper deals with the efficiency evaluations in a synchronous reluctance motor (SynRM) using a coupled transient finite element method (FEM) and Preisach modeling, which is Presented to analyze the characteristics under the effect of saturation and hysteresis loss. The focus of this paper is the efficiency evaluation relative to hysteresis loss, copper loss, etc. on the basis of speed, load condition in a SynRM. Computer simulation and experimental result for the efficiency using dynamometer show the propriety of the proposed method.

  • PDF