• 제목/요약/키워드: Saturation

검색결과 4,855건 처리시간 0.041초

Pb(Zr, Ti)$O_3$ 박막에서 결정립 크기 포화 현상에 관한 연구 (A Study on the Saturation of Grain Size in Pb(Zr, Ti)$O_3$ Thin Films)

  • 이장식;김찬수;주승기
    • 한국세라믹학회지
    • /
    • 제37권6호
    • /
    • pp.530-536
    • /
    • 2000
  • During the grain growth of the PZT thin films by selective nucleation method using PZT seed, it was found that the grain size was saturated with the annealing temperature. The saturation of grain size was analyzed by the interfacial energy which appeared during the crystallization. The factors affecting the saturation of grain size were found to be the interfacial energy between perovskite phase and pyrochlore phase, and PZT thin film and the bottom Pt electrode. When the ion damage was introduced to the grain-size saturated PZT thin films, further lateral growth was observed. Pt bottom electrode thickness was changed to control the interfacial energy between the PZT thin film and the Pt bottom electrode. When Pt thickness was increased, the grain size was also increased, because the lattice parameter of Pt films was increased with the thickness of the Pt films. The incubation time of nucleation was increased with the amount of the ion damage on the Pt films.

  • PDF

포화함수를 이용한 주파수영역에서의 PI제어기설계 (The Design of PI controller using a saturation function in frequency domain)

  • 오승록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.326-328
    • /
    • 2009
  • we an autotuning algorithm for PI controller with unknown plant. The proposed algorithm uses a saturation function and time delay element as a test signal. Since the integral element of PI controller reduces a phase margin and amplitude margin in the closed loop system, the closed loop system could be resulted in unstable with PI controller, To avoid unstable in the closed loop system with PI controller, the proposed algorithm identifies one point information in the 3rd quadrant of Nyquist plot with a time delay element. The proposed method improves an accuracy of one point identified information with one saturation function.

  • PDF

입력 제한 조건을 고려한 불확실성 시스템의 출력 귀환 LPV 제어 (Output-feedback LPV Control for Uncertain Systems with Input Saturation)

  • 김성현
    • 제어로봇시스템학회논문지
    • /
    • 제19권6호
    • /
    • pp.489-494
    • /
    • 2013
  • This paper tackles the problem of designing a dynamic output-feedback control for linear discrete-time norm-bounded uncertain systems with input saturation. By employing a LPV (Linear Parameter Varying) instead of LTI (Linear Time-Invariant) control, the useful information on interpolation parameters appearing in the procedure of representing saturation nonlinearity as a convex polytope is additionally applied in the control design procedure. By solving the addressed problem that can be recast into a convex optimization problem characterized by LMIs (Linear Matrix Inequalities) with one prescribed scalar, the vertices of convex set containing an LPV output-feedback control gain and the associated maximal invariant set of initial states are simultaneously obtained.

펄스 옥시미터의 동잡음 제거 필터 설계 (Design of an Adaptive Noise Canceller for the Motion Artifact Removal of a Pulse Oximetry Signal)

  • 김도영;김일환
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.89-93
    • /
    • 2006
  • Pulse oximetry, which monitors non-invasively the oxygen saturation in blood, is influenced by patient's respiration, movement or a factor of an environment. Specially, it's difficult to measure a PPG (Photoplethsmography) signal from the moving patient because of the motion artifact. Accordingly, it is required to extract the pure PPG signal from the PPG signal to measure oxygen saturation. In this paper, we propose an adaptive noise canceller to improve the performance of motion artifact removal. Then we design a hardware system for real time monitoring of the oxygen saturation. The proposed algorithm estimates the slope of transition rate between two different wavelength signals.

  • PDF

동적전압보상기를 구성하기 위한 정합변압기의 자속포화현상 모델링 (Flux Saturation Modeling of Matching Transformer for Dynamic Voltage Restore)

  • 김왕래;강호현;전희종;한운동;오중민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.428-431
    • /
    • 2006
  • Matching transformer in Dynamic Voltage Compensator is needed for grid connection and isolation. Flux saturation in transformer will be occurred by voltage of transformer from inverter and DC offset voltage and flux saturation makes over current in transformer. In this paper, mathematical modeling of matching transformer is proposed for flux saturation simulation of Dynamic Voltage Compensator.

  • PDF

Adaptive Flux Observer with On-line Inductance Estimation of an Interior PM Synchronous Machine Considering Magnetic Saturation

  • Jeong, Yu-Seok;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.188-197
    • /
    • 2009
  • This paper presents an adaptive flux observer to estimate stator flux linkage and stator inductances of an interior permanent-magnet synchronous machine considering magnetic saturation. The concept of static and dynamic inductances due to saturation is introduced in the machine model to describe the relationship between current and flux linkage and the relationship between their time derivatives. A flux observer designed in the stationary reference frame with constant inductance is analyzed in the rotor reference frame by a frequency-response characteristic. An adaptive algorithm for an on-line inductance estimation is proposed and a Lyapunov-based analysis is given to discuss its stability. The dynamic inductances are estimated by using Taylor approximation based on the static inductances estimated by the adaptive method. The simulation and experimental results show the feasibility and performance of the proposed technique.

Characteristics Analysis of Single Phase Induction Motor via Equivalent Circuit Method and Considering Saturation Factor

  • Cho, Su-Yeon;Kim, Won-Ho;Jin, Chang-Sung;Kang, Dong-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.178-183
    • /
    • 2014
  • This paper presents a motor characteristics analysis method using an equivalent circuit. Motor characteristics analysis via equivalent circuit is very important for designing a high efficiency single phase induction motor. The accuracy of the motor characteristics depends on the accuracy of the parameters, especially saturation factor, which determines the cyclical relationship in the analysis process. Therefore, using the proposed method, the saturation factor was calculated using the iteration routine and numerical technique. The proposed method was verified by comparing the finite element method results and the dynamo test results of manufactured prototype model.

제한된 구동기 용량을 갖는 선형 시스템의 스케듈링 $H_{\infty}$ 제어기 설계 (Design of Scheduled $H_{\infty}$ Control for Linear Systems with Limited Actuator Capacity)

  • 송용희;김진훈
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권9호
    • /
    • pp.622-629
    • /
    • 2004
  • In practical control systems, the capacity of actuators is limited and this degrades the system performances and it is often a source of instability. To use full capacity of actuators, we adopt the gain scheduled control permitting the over saturation in controls. The basic idea of gain scheduled control is to use a higher gain control when the state variables are smaller and a lower gain control when the state variables are larger. First, we derive a constant H control and a reachable set while satisfying the degree of over saturation. Next, we divide this set into nested subsets and find $H_{\infty}$ controls at rack subsets while satisfying the degree of over saturation. Finally, the control gain is applied according to the status of states. Note that all procedures are done by solving linear matrix inequalities(LMI). Finally, we show the validity and applicability of our proposed control using the simulations of a six-story building subjected to the earthquake excitation.

퍼멀로이와 실리콘스틸의 적층 통한 전류센서의 선형성 및 포화도 개선 (Improved Linearity and Saturation of Current Sensor by Laminating Silicon Steel and Fermalloy)

  • 신정원;최봉석;하영호
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.194-201
    • /
    • 2015
  • The current sensor is used in industrial devices and power utilities. Core materials of these current sensors are divided into mainly two groups as silicon steel and fermalloy. Silicon steel has a wide saturation bandwidth but low sensitivity during low-current, whereas permalloy has a short saturation bandwidth but high sensitivity during low-current. In this paper, laminated silicon steel and permalloy by equal ratio is proposed to improve the linearity and saturation of current sensor. It is proved that the proposed core material has larger bandwidth than fermalloy as well as higher sensitivity than silicon steel. When comparing simulation results by FLUX 3D, the proposed method has also better performance than the previous core materials.

A New IEEE 802.11 DCF Utilizing Freezing Experiences in Backoff Interval and Its Saturation Throughput

  • Sakakibara, Katsumi;Taketsugu, Jumpei
    • Journal of Communications and Networks
    • /
    • 제12권1호
    • /
    • pp.43-51
    • /
    • 2010
  • IEEE 802.11 defines distributed coordination function (DCF), which is characterized by CSMA/CA and binary exponential backoff (BEB) algorithm. Most modifications on DCF so far have focused on updating of the contention window (CW) size depending on the outcome of own frame transmission without considering freezing periods experienced in the backoff interval. We propose two simple but novel schemes which effectively utilize the number of freezing periods sensed during the current backoff interval. The proposed schemes can be applied to DCF and its family, such as double increment double decrement (DIDD). Saturation throughput of the proposed schemes is analyzed by means of Bianchi's Markovian model. Computer simulation validates the accuracy of the analysis. Numerical results based on IEEE 802.11b show that up to about 20% improvement of saturation throughput can be achieved by combining the proposed scheme with conventional schemes when applied to the basic access procedure.