• Title/Summary/Keyword: Saturated Vapor Pressure

검색결과 54건 처리시간 0.019초

수산화광물(水酸化鑛物)인 수골석(水滑石), Xonotlite, 활석(滑石), 투각섬석(透角閃石) 및 Antigorite의 열수합성(熱水合成) (Hydrothermal Syntheses of Hydrous Minerals, Brucite, Xonotlite, Talc, Tremolite, and Antigorite)

  • 박홍봉
    • 자원환경지질
    • /
    • 제13권1호
    • /
    • pp.65-68
    • /
    • 1980
  • Dolomite and quartz, starting materials, were mixed by the mole ratio of dolomite versus quartz with 1 : 0, 1 : 1, and 2 : 1, and of which was heated under saturated water vapor pressure of $20kg/cm^2(211.4^{\circ}C)$, $80kg/cm^2(293.6/C)$ and $120kg/cm^2(323.1^{\circ}C)$, respectively, during 20 hours. The results of the hydrothermal syntheses are as follows: 1) calcite crystals were formed at all cases of the reation 2) brucite crystals were formed when dolomite was heated under the saturated vapor pressure of $80kg/cm^2$ during 20 hours. 3) talc, tremolite, xonotlite, and antigorite were formed under saturated vapor pressure of $80kg/cm^2$ by 20 hours reaction.

  • PDF

R-134a의 열역학적 물성치 계산과 냉동 성능에 관한 연구 (Calculation of the Thermodynamic Properties of R-134a and A Preliminary Study of the Refrigeration Performance)

  • 박영무;이홍원
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.286-296
    • /
    • 1991
  • The thermodynamic properties of R134a, the prospective R12 alternative, have been computerized using Martin-Hou equation of state and the coefficients given by Willson-Basu. Several experimental results in literatures for PVT data, saturated vapor pressure, saturated liquid density are compared with the calculated results to investigate the accuracy. The average deviation (max. deviation) is 0.13% (0.25%) for saturated liquid density, 0.25% (0.8%) for PVT data. Thermodynamic properties, enthalpy, entropy are compared with the NIST's. The maximum percent difference is 3% for saturated liquid enthalpy, 1.5% for saturated vapor enthalpy, 4% saturated liquid entropy, and 0.7% for saturated vapor entropy. Correction of W-B's coefficients and inclusion of the sixth term of M-H EOS for improvement of accuracy are recommended. R134a and R12 are compared with respect to refrigeration performance. COP's are different from each other within 3%. Refrigeration effect of R134a is superior to that of R12 but refrigeration capacity of R134a is inferior to that of R12 because the volumetric efficiency of the system using R134a is lower than that of the system using R12.

  • PDF

PDPA와 고속카메라에 의한 액상부탄 간헐분무 특성 연구 (The Characteristics of a Transient Liquefied Butane Spray using PDPA and High Speed Camera)

  • 윤준규;임종한;김종현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.466-474
    • /
    • 2004
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a flash boiling spray is expected when the surround pressure is below the saturated vapor pressure of the butane(0.23MPa 98K). The axial velocities. radial velocities. and size distributions in butane sprays were measured with PDPA(Phase Doppler Particle Analyzer) system. Sprays were macroscopically observed by using the high speed camera in case that the surround pressure is 0.37MPa and 0.15MPa. respectively. Compared with the conventional spray. the reversed results were investigated when the surround pressure is below the saturated vapor pressure of the butane.

등온 수직벽의 자연대류 막응축 모델에 관한 비교분석 (Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall)

  • 성현찬;김경훈
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1380-1387
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation of pure saturated or superheated vapor under atmospheric pressure on isothermal vertical wall have been reviewed. To investigate the effects such as inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor, the effects of superheated temperature and variable properties in liquid and vapor layers are examined and then a new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

등온 수직벽의 자연대류 막응축 모델에 관한 비교분석 (Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall)

  • 성현찬;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.31-36
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation or pure saturated or superheated vapor under atmospheric pressure on isotheraml vertical wall have been reviewed. To investigate the effects of inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor the effects of superheated temperature and variable properties in liquid and vapor layer are examined and then new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

  • PDF

신경회로망을 이용한 증기표의 함수근사 (Function approximation of steam table using the neural networks)

  • 이태환;박진현
    • 한국정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.459-466
    • /
    • 2006
  • 열성능 평가를 위한 수치해석에서는 온도, 압력, 건도, 체적, 엔탈피, 엔트로피 등의 열역학적 성질들의 수치값이 필요하다. 그러나 이러한 성질들을 포함하고 있는 증기표를 그대로 사용할 수 없기 때문에, 효과적으로 모델링하여야 한다. 이러한 관점에서 함수근사 특성을 가진 신경회로망을 하나의 대안으로 검토하였다. 신경 회로망은 포화증기 영역과 과열증기 영역에 대해서 따로 구성하였다. 포화증기 영역에 대해서는 하나의 입력으로 7개의 출력을 얻을 수 있도록 하였으며, 각각 10개와 20개의 노드를 가진 은닉층을 구성 하였다. 과열증기 영역에 대해서는 2개의 입력으로 3개의 출력을 얻을 수 있도록 하였으며, 각각 15개와 25개의 노드를 가진 은닉층을 구성하였다. 제안된 모델은 온도, 엔탈피, 엔트로피의 백분율오차가 대부분 ${\pm}0.005%$, 압력이나 비체적의 백분율오차도 대부분 ${\pm}0.025%$ 범위 내로 수렴시킬 수 있었다. 이 성공적인 결과로부터 증기 표를 함수근사하는데 있어서 신경회로망이 아주 강력한 수단이 될 수 있음을 확인할 수 있었다.

이젝터를 적용한 팽창기체 흡입 냉동시스템의 성능향상 해석 연구 (Theoretical study on the performance improvement of refrigeration system installed with ejector entraining expansion gases after expansion process)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.828-833
    • /
    • 2014
  • 본 연구는 이젝터 팽창기를 적용한 냉동기에서 팽창한 냉매가 액기분리기에 포집된 후, 이 중 포화기체의 일부는 이젝터로 재흡입되고, 포화액체는 증발기에 유입되어 증발된 후 액기분리기의 잔여 기체와 혼합되어 압축되는 공정을 고안하여 특성을 해석하였다. 본 공정의 특성은 이젝터에서 등엔트로피 팽창 후 액체량의 증가로 냉동능력이 증가하고, 압축기에 유입되는 기체의 압력이 상승하게 되어 압축일이 감소함으로써 효율이 증가하게 된다. 냉매 R134a를 적용하는 냉장고 시스템과 본 고안 시스템을 비교한 결과, 이젝터에서 압력이 65% 저하될 때 COP는 27.8%가 증가된 최대값이 되었다. 다른 냉매의 경우 R401A가 75% 압력강하에서 40.1%의 COP 증가를 보였다. 이젝터의 디퓨져에서의 압력 상승율이 20%~60%까지 변화될 때, COP 증가율은 2.6%~3%로 영향이 매우 적었다.

2011년 강원 폭설과 GPS 가강수량의 상관성 분석 (Correlation Analysis between GPS Precipitable Water Vapor and Heavy Snowfall on Gangwon Province in Early 2011)

  • 송동섭
    • 한국측량학회지
    • /
    • 제30권1호
    • /
    • pp.97-104
    • /
    • 2012
  • 본 연구에서는 2011년 강원도 영동 지방의 폭설 기간 동안 GPS 위성 신호의 대류권 지연량 추정으로부터 대기 가강수량을 복원하였다. 폭설이 발생하는 기간 동안에 GPS 가강수량과 신적설 발생량과의 상관관계에 대한 분석을 실시하였다. 분석 결과, GPS를 이용하여 복원한 대류권에서의 가강수량 증가가 발생된 이후에 강설량이 증가하는 추세를 나타냈다. 또한 웨이블릿을 이용한 주기 분석에서는 본 연구기간에 한해서 GPS 가강수량의 주기가 포화수증기압의 주기와 유사한 것으로 검출되었다. GPS 가강수량의 감소와 이에 대응하는 신적설량의 증감은 두 연구 지역인 강릉과 울진에서 모두 다르게 증감하는 경향을 나타냈다. 폭설 기간 동안 GPS 가강수량과 포화수증기압의 상관 계수는 강설이 발생하지 않는 기간 동안의 결과와는 달리 양의 상관성을 갖는 것으로 나타났다.

수평평판의 층류 막응축에서 압력의 영향 (The Effect of Pressure on Laminar Film Condensation along a Horizontal Plate)

  • 이억수;이승홍
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.945-953
    • /
    • 2008
  • Laminar film condensation of saturated vapor in forced flow over a flat plate is analysed. The problem is formulated as exact boundary-layer solution and integral approximate solution. From numerical solutions of the governing equations, it is found that the energy transfer by convection and the effect of inertia term in the momentum equation in negligibly small for low pressure but quite important for high pressure. The condensate rate, liquid-vapor interfacial shear stress and local heat transfer are strongly dependent on the reduced pressure $P_r$ and the modified Jacob number Ja/Pr.

기-액흐름 연속누출에 의한 개방공간 증기운 폭발사고의 영향평가 (The Consequence Analysis for Unconfined Vapor Cloud Explosion Accident by the Continuous Release of Gas-Liquid Flow)

  • 장서일;이헌창;김태옥
    • 대한안전경영과학회지
    • /
    • 제4권3호
    • /
    • pp.35-43
    • /
    • 2002
  • For the unconfined vapor cloud explosion accident by the continuous release of gas-liquid flow of various saturated liquids in a vessel at ground level, overpressures were estimated and analyzed with various release conditions and materials by TNT equivalency model with vapor dispersion. We found that at same release conditions, overpressure showed n-heptane > xylene > n-hexane > toluene > n-heptane > benzene, respectively and that overpressure was increased with increasing the hole diameter and the storage pressure, but it was increased with decreasing the wind speed, the interested distance, and the vessel thickness.