• Title/Summary/Keyword: Saturated Vapor Pressure

Search Result 54, Processing Time 0.022 seconds

Hydrothermal Syntheses of Hydrous Minerals, Brucite, Xonotlite, Talc, Tremolite, and Antigorite (수산화광물(水酸化鑛物)인 수골석(水滑石), Xonotlite, 활석(滑石), 투각섬석(透角閃石) 및 Antigorite의 열수합성(熱水合成))

  • Park, Hong Bong
    • Economic and Environmental Geology
    • /
    • v.13 no.1
    • /
    • pp.65-68
    • /
    • 1980
  • Dolomite and quartz, starting materials, were mixed by the mole ratio of dolomite versus quartz with 1 : 0, 1 : 1, and 2 : 1, and of which was heated under saturated water vapor pressure of $20kg/cm^2(211.4^{\circ}C)$, $80kg/cm^2(293.6/C)$ and $120kg/cm^2(323.1^{\circ}C)$, respectively, during 20 hours. The results of the hydrothermal syntheses are as follows: 1) calcite crystals were formed at all cases of the reation 2) brucite crystals were formed when dolomite was heated under the saturated vapor pressure of $80kg/cm^2$ during 20 hours. 3) talc, tremolite, xonotlite, and antigorite were formed under saturated vapor pressure of $80kg/cm^2$ by 20 hours reaction.

  • PDF

Calculation of the Thermodynamic Properties of R-134a and A Preliminary Study of the Refrigeration Performance (R-134a의 열역학적 물성치 계산과 냉동 성능에 관한 연구)

  • Park, Y.M.;Lee, H.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.286-296
    • /
    • 1991
  • The thermodynamic properties of R134a, the prospective R12 alternative, have been computerized using Martin-Hou equation of state and the coefficients given by Willson-Basu. Several experimental results in literatures for PVT data, saturated vapor pressure, saturated liquid density are compared with the calculated results to investigate the accuracy. The average deviation (max. deviation) is 0.13% (0.25%) for saturated liquid density, 0.25% (0.8%) for PVT data. Thermodynamic properties, enthalpy, entropy are compared with the NIST's. The maximum percent difference is 3% for saturated liquid enthalpy, 1.5% for saturated vapor enthalpy, 4% saturated liquid entropy, and 0.7% for saturated vapor entropy. Correction of W-B's coefficients and inclusion of the sixth term of M-H EOS for improvement of accuracy are recommended. R134a and R12 are compared with respect to refrigeration performance. COP's are different from each other within 3%. Refrigeration effect of R134a is superior to that of R12 but refrigeration capacity of R134a is inferior to that of R12 because the volumetric efficiency of the system using R134a is lower than that of the system using R12.

  • PDF

The Characteristics of a Transient Liquefied Butane Spray using PDPA and High Speed Camera (PDPA와 고속카메라에 의한 액상부탄 간헐분무 특성 연구)

  • 윤준규;임종한;김종현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.466-474
    • /
    • 2004
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a flash boiling spray is expected when the surround pressure is below the saturated vapor pressure of the butane(0.23MPa 98K). The axial velocities. radial velocities. and size distributions in butane sprays were measured with PDPA(Phase Doppler Particle Analyzer) system. Sprays were macroscopically observed by using the high speed camera in case that the surround pressure is 0.37MPa and 0.15MPa. respectively. Compared with the conventional spray. the reversed results were investigated when the surround pressure is below the saturated vapor pressure of the butane.

Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall (등온 수직벽의 자연대류 막응축 모델에 관한 비교분석)

  • Sung, Hyun-Chan;Kim, Kyoung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1380-1387
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation of pure saturated or superheated vapor under atmospheric pressure on isothermal vertical wall have been reviewed. To investigate the effects such as inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor, the effects of superheated temperature and variable properties in liquid and vapor layers are examined and then a new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

Comparative Analysis of Models for Free Convective Film Condensation on an Isothermal Vertical Wall (등온 수직벽의 자연대류 막응축 모델에 관한 비교분석)

  • Sung, Hyun-Chan;Kim, Kyoung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.31-36
    • /
    • 2000
  • The existing theoretical models for steady two-dimensional free convective laminar film condensation or pure saturated or superheated vapor under atmospheric pressure on isotheraml vertical wall have been reviewed. To investigate the effects of inertia, thermal convective and liquid-vapor interface shear stress, the models of constant or variable properties in liquid film for condensation of saturated vapor are compared in detail with Nusselt model. Also, for condensation of superheated vapor the effects of superheated temperature and variable properties in liquid and vapor layer are examined and then new correlation is proposed to predict the heat transfer. The results are in good agreement with the Shang's correlation within 2% errors.

  • PDF

Function approximation of steam table using the neural networks (신경회로망을 이용한 증기표의 함수근사)

  • Lee, Tae-Hwan;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.459-466
    • /
    • 2006
  • Numerical values of thermodynamic properties such as temperature, pressure, dryness, volume, enthalpy and entropy are required in numerical analysis on evaluating the thermal performance. But the steam table itself cannot be used without modelling. From this point of view the neural network with function approximation characteristics can be an alternative. the multi-layer neural networks were made for saturated vapor region and superheated vapor region separately. For saturated vapor region the neural network consists of one input layer with 1 node, two hidden layers with 10 and 20 nodes each and one output layer with 7 nodes. For superheated vapor region it consists of one input layer with 2 nodes, two hidden layers with 15 and 25 nodes each and one output layer with 3 nodes. The proposed model gives very successful results with ${\pm}0.005%$ of percentage error for temperature, enthalpy and entropy and ${\pm}0.025%$ for pressure and specific volume. From these successful results, it is confirmed that the neural networks could be powerful method in function approximation of the steam table.

Theoretical study on the performance improvement of refrigeration system installed with ejector entraining expansion gases after expansion process (이젝터를 적용한 팽창기체 흡입 냉동시스템의 성능향상 해석 연구)

  • Yun, Sangkook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.828-833
    • /
    • 2014
  • In this paper, the performance characteristics for newly developed ejector refrigeration system, which is that the part of saturated vapor from liquid-vapor separator after ejector expansion process is entrained in ejector, and the saturated liquid flows in the evaporator and compressed with the rest of vapor in separator, is studied. The reasons of the performance improvement of refrigeration system are that the refrigeration capacity is increased due to quality reduction after iso-entropic expansion process by ejector and the compression work is reduced because of the relatively high pressure of vapor refrigerant before compression process. The comparison results of the ejector system entraining expansion gases with the present residential freezer show that the COP increases to 27.8% maximum in case of the pressure drop to 65% of high pressure of freezer, and to 40.1% for 75% pressure drop of refrigerant R401A. The COP improvement rate with 20%~60% pressure lift in diffuser of ejector is only 2.6%~3%.

Correlation Analysis between GPS Precipitable Water Vapor and Heavy Snowfall on Gangwon Province in Early 2011 (2011년 강원 폭설과 GPS 가강수량의 상관성 분석)

  • Song, Dong-Seob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.97-104
    • /
    • 2012
  • In this paper, the GPS precipitable water vapor was retrieved by estimating of GPS signal delay in the troposphere during the progress of heavy snowfall on the Gangwon Province, 2011. For this period, the time series analysis between GPS precipitable water vapor and fresh snow depth was accomplished. The time series and the comparison with the GPS precipitable water vapor and the fresh snow depth indicates that the temporal change of two variations is closely related to the progress of the heavy snowfall. Also, the periodicity of GPS precipitable water vapor using the wavelet transform method was showed a similar cycle of saturated water vapor pressure as the limitation of this study span. The result shows that the decrement of GPS precipitable water vapor was conflicted with the increment of fresh snow depth at two sites, Gangneung and Uljin. The correlation between the GPS precipitable water vapor and the saturated water vapor pressure for the event was showed a positive correlation, compare with the non-heavy snowfall periods.

The Effect of Pressure on Laminar Film Condensation along a Horizontal Plate (수평평판의 층류 막응축에서 압력의 영향)

  • Lee, Euk-Soo;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.945-953
    • /
    • 2008
  • Laminar film condensation of saturated vapor in forced flow over a flat plate is analysed. The problem is formulated as exact boundary-layer solution and integral approximate solution. From numerical solutions of the governing equations, it is found that the energy transfer by convection and the effect of inertia term in the momentum equation in negligibly small for low pressure but quite important for high pressure. The condensate rate, liquid-vapor interfacial shear stress and local heat transfer are strongly dependent on the reduced pressure $P_r$ and the modified Jacob number Ja/Pr.

The Consequence Analysis for Unconfined Vapor Cloud Explosion Accident by the Continuous Release of Gas-Liquid Flow (기-액흐름 연속누출에 의한 개방공간 증기운 폭발사고의 영향평가)

  • 장서일;이헌창;김태옥
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.35-43
    • /
    • 2002
  • For the unconfined vapor cloud explosion accident by the continuous release of gas-liquid flow of various saturated liquids in a vessel at ground level, overpressures were estimated and analyzed with various release conditions and materials by TNT equivalency model with vapor dispersion. We found that at same release conditions, overpressure showed n-heptane > xylene > n-hexane > toluene > n-heptane > benzene, respectively and that overpressure was increased with increasing the hole diameter and the storage pressure, but it was increased with decreasing the wind speed, the interested distance, and the vessel thickness.