• Title/Summary/Keyword: Sample array

Search Result 206, Processing Time 0.036 seconds

Pb Isotopic Composition of Yeonhwa and Janggun Pb-Zn Ore Deposits and Origin of Pb: Role of Precambrian Crustal Basement and Mesozoic Igneous Rocks (연화 및 장군 연-아연 광상의 Pb 동위원소 조성 및 Pb의 근원: 선캠브리아 기저 지각 및 중생대 화성암의 역할)

  • Park Kye-Hun;Chang Ho Wan
    • The Journal of the Petrological Society of Korea
    • /
    • v.14 no.3 s.41
    • /
    • pp.141-148
    • /
    • 2005
  • Lead isotopic compositions are analyzed from the sulfide minerals of the Yeonhwa, Janggun and Uljin deposits and from host limestone, intrusives, and basement rocks to reveal the source of Pb in these deposits. In the $^{206}Pb/^{204}Pb$ vs $^{207}Pb/^{204}Pb$ plot, Galenas from the Yeonhwa mine display relatively well defined positive linear array, similar to the Precambrian basement rocks of the Korean peninsula. A galena sample from the Uljin mine, Janggun limestone and the basement rocks also follow the variation of Yeonhwa mine. However, ore minerals from the Janggun mine, having relatively low $^{206}Pb/^{204}Pb$ values, reveal offset from such trend toward lower $^{207}Pb/^{204}Pb$ values. Considering the fact that Mesozoic igneous rocks and ores within the Gyeongsang basin display considerably lower $^{207}Pb/^{204}Pb$ values than basement rocks of the Korean peninsula, the deviation of Janggun ore minerals can be interpreted as to reflect mixing between leads from old continental crustal materials and from Mesozoic igneous rocks with more mantle signature. The lead of the Yeonhwa and Uljin mine, following trend of Precambrian basement rather well, seems to have been originated mostly from such basement. However, regarding that they occupy low $^{207}Pb/^{204}Pb$ side of the variation trend of the basement, the possibility of having some leads derived from the Mesozoic igneous rocks cannot be excluded.

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

Genetic diversity and divergence among Korean cattle breeds assessed using a BovineHD single-nucleotide polymorphism chip

  • Kim, Seungchang;Cheong, Hyun Sub;Shin, Hyoung Doo;Lee, Sung-Soo;Roh, Hee-Jong;Jeon, Da-Yeon;Cho, Chang-Yeon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.11
    • /
    • pp.1691-1699
    • /
    • 2018
  • Objective: In Korea, there are three main cattle breeds, which are distinguished by coat color: Brown Hanwoo (BH), Brindle Hanwoo (BRH), and Jeju Black (JB). In this study, we sought to compare the genetic diversity and divergence among there Korean cattle breeds using a BovineHD chip genotyping array. Methods: Sample data were collected from 168 cattle in three populations of BH (48 cattle), BRH (96 cattle), and JB (24 cattle). The single-nucleotide polymorphism (SNP) genotyping was performed using the Illumina BovineHD SNP 777K Bead chip. Results: Heterozygosity, used as a measure of within-breed genetic diversity, was higher in BH (0.293) and BRH (0.296) than in JB (0.266). Linkage disequilibrium decay was more rapid in BH and BRH than in JB, reaching an average $r^2$ value of 0.2 before 26 kb in BH and BRH, whereas the corresponding value was reached before 32 kb in JB. Intra-population, interpopulation, and Fst analyses were used to identify candidate signatures of positive selection in the genome of a domestic Korean cattle population and 48, 11, and 11 loci were detected in the genomic region of the BRH breed, respectively. A Neighbor-Joining phylogenetic tree showed two main groups: a group comprising BH and BRH on one side and a group containing JB on the other. The runs of homozygosity analysis between Korean breeds indicated that the BRH and JB breeds have high inbreeding within breeds compared with BH. An analysis of differentiation based on a high-density SNP chip showed differences between Korean cattle breeds and the closeness of breeds corresponding to the geographic regions where they are evolving. Conclusion: Our results indicate that although the Korean cattle breeds have common features, they also show reliable breed diversity.

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • Hwang, In-Chan;Seo, Gwan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF

A survey on pesticide residues of imported fruits circulated in Gyeonggido (경기도내 유통 수입과실류의 잔류농약 실태조사)

  • Cho, Yun-Sik;Kang, Jeong-Bok;Kim, Yang-Hee;Jeong, Jin-A;Huh, Jeong-Weon;Lee, So-Hyun;Lim, Young-Sik;Bae, Ho-Jeong;Kang, Heung-Gyu;Lee, Jeong-Hee;Jung, Eun-Sook;Lee, Byoung-Hoon;Park, Yong-Bok;Lee, Jong-Bok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • We tested for pesticide residues in 124 samples of 22 different items of imported fruits circulated in Gyeonggido. Total 218 pesticides were analyzed by multi-residue method using gas chromatography/nitrogen phosphorus detector-electron capture detector (GC/NPD-ECD), time of flight/mass spectrometer (TOF/MS), ultra performance liquid chromatography/photo diode array (UPLC/PDA), high performance liquid chromatography/fluorescence detector (HPLC/FLD) and mass spectrometer (LC/MS/MS). The pesticides were detected in 18 fruits samples, ranging 0.003~0.3 mg/kg and no samples had violative residue. The separation test to 14 sample pesticides detected was conducted to monitor the current status of pesticide residues according to the partial characteristic. The pesticides were detected in 14 peels ranging 0.03~1.5 mg/kg and 2 fleshes in less than detection limits. These results indicate that imported fruits are safe when the human takes normally but even the small amount of pesticides is harmful when the human takes it in a prolonged period. Therefore, the pesticide residual amounts of imported friuts should be constantly monitored for food safety.

Multiresidue matrix solid phase dispersion (MSPD) extraction and HPLC determination of tetracyclines in animal muscle tissue (시료고체상분산(matrix solid phase dispersion)전처리법을 이용한 식육중 테트라사이클린계 항생물질 동시정량분석)

  • Kang, Hwan-goo;Son, Seong-wan;Cho, Byung-hoon;Lee, Hye-sook;Park, Shin-ja;Kim, Jae-hak;Cho, Myung-haing
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.541-550
    • /
    • 1996
  • Tetracycline antibiotics have been widely used not only therapeutics but feed additives. There are many methods for the isolation and determination of tetracycline antibiotics in animal muscle tissue. But those methods take much time and labor, so it is difficult to analyse many samples simultaneously. A rapid isolation method and liquid chromatographic determination of tetracycline antibiotics in animal muscle tissue (bovine, porcine, chicken) is presented. Blank control and tetracyclines fortified samples (0.5g) were blended with $C_{18}$ containing 0.05g each of oxalic acid and disodium ethylenediaminetetraacetate. After homogenize, homogenate was transferred to glass column made from 10ml glass syringe and compressed to 4~4.5ml volume. A column made from the $C_{18}$/meat matrix was washed with hexane (8ml) and dichloromethane (8ml, if needed), following which the tetracyclines were eluted,vith methanol or 0.01M methanolic oxalic acid (8ml). The eluates containing tetracyclines analytes were free from interfering compounds when analysed by HPLC with UV detection (photodiode array at 360nm). Standard curve for each tetracycline showed a linear response at the range of $0.05{\sim}1.0{\mu}g/ml$ and tetracycline antibiotics were eluted within 4ml of eluted volume. All tetracycline antibiotics except tetracycline were stable during the concentration process at $40^{\circ}C$ and time required for concentration was 3~4 hours. Fortified samples containing oxalic aicd and EDTA represented more good recoveries than those of not-contained sample. Recoveries were 91.8~110.1% (oxytetracycline; OTC), 57.7~79.5% (tetracycline; TC), 78.1~88.6% (chlortetracyclines; CTC) and 88.4~100.6% (doxycycline; DC) in pork tissue, 101.1~126.8% (OTC), 66.4~75.4% (TC), 79.2~88.1% (CTC) and 69.3~86.7% (DC) in beef tissue, and 90.8~95.6% (OTC), 66.2~84.4% (TC), 75.7~77.2% (CTC) and 55.6~80.7% (DC) in chicken muscle tissue. The detection limits validated in muscle tissue by this method were $0.05{\mu}g/g$ for OTC and TC, and $0.1{\mu}g/g$ for CTC and DC.

  • PDF

미세금형 가공을 위한 전기화학식각공정의 유한요소 해석 및 실험 결과 비교

  • Ryu, Heon-Yeol;Im, Hyeon-Seung;Jo, Si-Hyeong;Hwang, Byeong-Jun;Lee, Seong-Ho;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.81.2-81.2
    • /
    • 2012
  • To fabricate a metal mold for injection molding, hot-embossing and imprinting process, mechanical machining, electro discharge machining (EDM), electrochemical machining (ECM), laser process and wet etching ($FeCl_3$ process) have been widely used. However it is hard to get precise structure with these processes. Electrochemical etching has been also employed to fabricate a micro structure in metal mold. A through mask electrochemical micro machining (TMEMM) is one of the electrochemical etching processes which can obtain finely precise structure. In this process, many parameters such as current density, process time, temperature of electrolyte and distance between electrodes should be controlled. Therefore, it is difficult to predict the result because it has low reliability and reproducibility. To improve it, we investigated this process numerically and experimentally. To search the relation between processing parameters and the results, we used finite element simulation and the commercial finite element method (FEM) software ANSYS was used to analyze the electric field. In this study, it was supposed that the anodic dissolution process is predicted depending on the current density which is one of major parameters with finite element method. In experiment, we used stainless steel (SS304) substrate with various sized square and circular array patterns as an anode and copper (Cu) plate as a cathode. A mixture of $H_2SO_4$, $H_3PO_4$ and DIW was used as an electrolyte. After electrochemical etching process, we compared the results of experiment and simulation. As a result, we got the current distribution in the electrolyte and line profile of current density of the patterns from simulation. And etching profile and surface morphologies were characterized by 3D-profiler(${\mu}$-surf, Nanofocus, Germany) and FE-SEM(S-4800, Hitachi, Japan) measurement. From comparison of these data, it was confirmed that current distribution and line profile of the patterns from simulation are similar to surface morphology and etching profile of the sample from the process, respectively. Then we concluded that current density is more concentrated at the edge of pattern and the depth of etched area is proportional to current density.

  • PDF

An Array-Type RGB Sensor for Precision Measurement of pH

  • Kim, Ji-Sun;Oh, Han-Byeol;Kim, A-Hee;Kim, Jun-Sik;Lee, Eun-Suk;Goh, Bong-Jun;Choi, Ju-Hyeon;Shin, Ye-Ji;Baek, Jin-Young;Lee, Ki Sung;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.700-704
    • /
    • 2015
  • As pH is a widely used index in chemical, medical, and environmental applications, research on pH sensors has been active in recent years. This study obtained RGB values by measuring the reflected light from a liquid sample to detect fine changes in pH, and performed mathematical modeling to investigate the relationship between the detected optical signal and pH value. Also, the trends in pH changes were easily identified by analyzing RGB values and displaying them in the color coordinate for easy visualization of data. This method implemented a user-friendly system that can measure and analyze in real time. This system can be used in many fields such as genetic engineering, environmental engineering, and clinical engineering, because it not only can measure pH but also replaces a colorimeter or turbidimeter.

Distribution of Abused Drugs in 275 Alcohol-positive Blood Samples of Korean Driver (음주운전자 275명 혈액 중 마약류 및 남용약물의 분석)

  • Choi, Hye-Young;Lee, Ju-Seon;Choi, Sang-Kil;Kim, Eun-Mi;Kim, Jae-Kyun;Kim, Young-Woon;Lim, Mi-Ae;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.137-146
    • /
    • 2008
  • Even though driving under the influence of drug (DUID) is a worldwide problem, we, Korea has no regulation system yet except for alcohol, and there are little cases reported related to DUID. In order to investigate the type of abused drugs for drivers in Korea, we tried to analyze controlled and non-controlled drugs in alcohol-positive blood samples. 275 whole bloods, which were positive for alcohol on the roadside test, were collected from the police for two months ($Nov.{\sim}Dec.$ 2006). The analytical strategy was constituted of three steps: First, alcohol in blood samples were confirmed and quantified by gas chromatography. Second, controlled drugs were screened by $Evidence_{investigator}\;^{TM}$ (Randox, U.K.) as preliminary test. It was based on immunoassay by biochip array analyzer. Nine groups of drug abuse were screened: amphetamines, methamphetamines, cannabis, cocaine, opiates, barbiturates, methadone, benzodiazepines I (oxazepam) & II (lorazepam). Finally, confirmation of these drugs was performed by GC-MS. Blood samples were extracted by solid-phase extraction by $RapidTrace^{TM}$ (Zymark, U.S.A.). After trimethylsilyl (TMS) derivatization, eluates were analyzed to GC-MS. Total 49 drugs were investigated in this study including controlled drugs, antidepressants, 1st generation antihistamines, dextromethorphan, nalbuphine, ketamine, etc. For rapid detection, we developed the automated identification system. It was made up a new software, "DrugMan", modified Chemstation data analysis menu and newly developed macro modules. A series of peak selection, identification and reporting of the results were performed automatically by this system. Concentrations of alcohol in 275 blood samples were ranged from 0.011 to 0.249% (average, 0.119%). Among 149 blood samples, just six samples (4.0%) were showed positive results to the immunoassay: one methamphetamine and five benzodiazepines group I. By GC-MS confirmation, only benzodiazepines were detected and methamphetamine was not detected from immunoassay positive blood sample. Besides these drugs, 5 chlorpheniramines, dextromethorphan, diazepam, doxylamine, ibuprofen, lidocaine and topiramate were also detected in whole bloods by GC-MS. Conclusively, the frequency of drug abuse for Korean drivers was relatively low. There was none case which illegal drug was detected. However these results were limited to alcohol positive blood samples, so it is necessary to analyze more samples including alcohol negative blood.

Determination of β-Carotene in Infant Formulas by High-Performance Liquid Chromatography (HPLC를 이용한 조제유류 중 베타카로틴 함량 분석 연구)

  • Hwang, Kyung Mi;Bae, Ji Won;Hu, Soo Jung;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.334-339
    • /
    • 2019
  • A procedure based on high-performance liquid chromatography (HPLC) is described to determine ${\beta}-carotene$ in infant formulas. The method for ${\beta}-carotene$ analysis was performed on a C18 reversed-phase column using acetonitrile/methanol/dichloromethane (6:1:3, v/v/v) as a mobile phase. ${\beta}-Carotene$ was determined in HPLC with photo diode array (PDA) detector. The parameters of validation were specificity, linearity, LOD, LOQ, accuracy, precision and repeatability. The specificity was confirmed by the retention time and the linearity ($R^2$), which was over 0.999 in the range of 0.125~2 mg/L. The detection and quantification limits were 0.064 and 0.193 mg/L, respectively. The accuracy and precision of this method using an STD spiked sample were 80~119% and 1.02~2.05% respectively. The method was applied to the analysis of various infant formula and follow-up formulas products containing ${\beta}-carotene$, and all the products contained acceptable levels of ${\beta}-carotene$ for nutrition labeling.