• 제목/요약/키워드: Saline solution

검색결과 769건 처리시간 0.031초

기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구 (A Study on the Contamination of Solution with Suction used in Tracheostomy Patients)

  • 임윤희;유광수
    • 한국보건간호학회지
    • /
    • 제12권2호
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

염류용액 방전의 온도 측정에 관한 연구 (A Study on the Temperature Measurement Using Optical Emission in Saline Solution Discharge with Pin to Plate Electrodes)

  • 김중균
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.66-71
    • /
    • 2016
  • In this study, electrical and spectroscopic characteristics were investigated in the pin to plate discharge of 0.9% weight per unit volume saline solution. The positive and positive- and negative-going dc pulse with 5% duty ratio were applied to tungsten pin electrode. The more amount of discharge current flew in negative discharge. The temperature, which is considered as a local value in the vicinity of vapor of discharge, was about 3,000K which is much higher than the value recommended to be controlled. It can be suggested that not only the temperature of liquid but also the local temperature of vapor is monitored to investigate damages on tissue or cells in biological application.

비턴넬형 중심정맥관 개방성 유지를 위한 헤파린 희석액 관류와 생리식염수 관류의 비교 (Comparison of Heparin Solution and 0.9% Normal Saline Solution Flushing to Secure the Patency of Non-Tunneled Central Venous Catheters)

  • 김지혜;서은지;박희정;김시현;민자;박정윤;김송철
    • 임상간호연구
    • /
    • 제20권3호
    • /
    • pp.326-336
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the effectiveness of heparin and 0.9% normal saline solution flushing for maintaining patency of non­tunneled central venous catheters in patients with surgery. Methods: A randomized controlled clinical trial was performed. Fifty­eight patients were prospectively enrolled and fifty-four patients were completed the study. The heparin group consisted of 30 patients given 100u/ml diluted heparin flushing and the normal saline group consisted of 24 patients with 0.9% sodium chloride flushing. Results: There was no significantly difference in occlusion between the heparin group and the normal saline group in non­tunneled central venous catheters' occlusion. Also there was no difference between these two groups in catheter­related infections. Conclusion: Flushing with 0.9% normal saline is as effective as flushing with heparin solution in maintaining the patency of non­tunneled central venous catheters. In this study, however, the duration of central line use was short and the infection occurrence was little. Further studies are warranted with a larger sample size at multiple centers.

생리식염액을 이용한 구강간호가 중환자실 환자의 구강상태에 미치는 효과 (The Effect of Oral Care with Normal Saline on Oral State of Patients in Intensive Care Unit)

  • 최선희;김영경
    • 성인간호학회지
    • /
    • 제16권3호
    • /
    • pp.452-459
    • /
    • 2004
  • Purpose: To investigate the effect of oral care either with normal saline or with tantum solution on the oral state of the patients in intensive care unit as well as the frequency of bacteria occurrence inside their oral cavities. Method: The study was performed from March thru May of 2003 on the nonequivalent control group non-synchronized quasi-experimental design. Forty subjects were selected for each group. The data were analyzed using the SPSS 10.0 Win. The pre-experimental homogeneity and post-experimental differences between the two groups were analyzed with t-test. Result: There was a significant difference in the oral cavity state between the experimental group that had used normal saline and the control group that had used tantum solution. Conclusion: Based on the results described above, it is considered that normal saline is more effective than the tantum solution for the oral care of the patients in intensive care unit.

  • PDF

수종의 저장용액에서의 치은섬유모세포 생존율의 비교연구 (Comparative study on survival rate of human gingival fibroblasts stored in different storage media)

  • 이희수;임유선
    • 한국치위생학회지
    • /
    • 제12권4호
    • /
    • pp.733-739
    • /
    • 2012
  • Objectives : To Compare the degree of survival rate of gingival fibroblasts, which is concerned with teeth adherence based on the type of avulsed tooth's storage solution. Methods : Different media gingival fibroblasts were stored in Dulbecco's modified Eagle's medium(DMEM), Hank's balanced salt solution(HBSS), milk, saline, and green tea in for 1, 2, 3 hours. And, MTT assay was conducted to compare survival rate of human gingival fibroblasts. Results : 1. The survival rate of gingival fibroblasts in DMEM and HBSS was higher than thoes in other storage media( Milk> Saline> Green tea). 2. The survival rate of gingival fibroblasts in milk, saline and green tea decreased as time passed. 3. Because of low osmotic pressure, green tea showed decrease of survival rate of gingival fibroblasts. Conclusion : DMEM and HBSS were the most effective storage media for gingival fibroblast. Among milk, saline, green tea, milk is most effective storage media for keeping gingival fibroblasts. Milk is recommended for storage media of avulsed tooth for keeping viability of cells.

Diagnostic Studies of Plasmas in Saline Solutions: the Frequency Effects and the Electrode Erosion Mechanism

  • Hsu, Cheng-Che
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.16-16
    • /
    • 2011
  • Plasmas in saline solutions receive considerable attention in recent years. How the operating parameters influence the plasma characteristics and how the electrode erosion occurs have been topics that require further study. In the first part of this talk, the effect of the frequency on the plasmas characteristics in saline solution driven by 50~1000 Hz AC power will be presented. Two distinct modes, namely bubble and jetting modes, are identified. The bubble mode occurs under low frequencies. In this mode, one mm-sized bubble is tightly attached to the electrode tip and oscillates with the applied voltage. With an increase in the frequency, it shows the jetting mode, in which many smaller bubbles are continuous formed and jetted away from the electrode surface. Multiple mechanisms that are potentially responsible to such a change in bubble dynamics have been proposed and the dominant mechanism is identified. From the Stark broadening of the hydrogen optical emission line, electron densities in both modes are estimated. It shows clearly that the driving frequency greatly influences the bubble dynamics, which in turn alters the plasma behavior. In the second part, the study of the erosion of a tungsten electrode immersed in saline solution under conditions suitable for bio-medical applications is presented. The electrode is immersed in 0.1 M saline solution and is positively or negatively biased using a DC power source up to 600 V. It is identified that when the electrode is positively biased, erosion by the surface electrolytic oxidation is the dominant mechanism with an applied voltage below 150 V. An increase in the applied voltage leads to the formation of the plasma and the damage by the plasma and the thermal effect becomes more prominent. The formation of the gas film at the electrode surface leads to the formation of the plasma and hinders the electrolytic erosion. In the negatively-biased electrode, no electrolytic oxidation is seen and the damage is mostly likely due to the plasma erosion and the thermal effect.

  • PDF

안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태 (The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops)

  • 박미정;이운정;김소라
    • 한국안광학회지
    • /
    • 제16권4호
    • /
    • pp.391-401
    • /
    • 2011
  • 목적: 국내 안경원의 시험착용렌즈와 관리용품의 관리 실태를 조사하고 분석함으로써 관리 소홀로 인하여 유발될 수 있는 사고의 위험성을 낮추고자 하였다. 방법: 콘택트렌즈 착용자들을 대상으로 시험착용렌즈의 착용 시 느끼는 점을 설문 조사하였으며, 콘택트렌즈를 취급하는 안경원의 안경사를 대상으로 시험착용 콘택트렌즈인 미용렌즈와 RGP 렌즈 그리고 렌즈 관리용품의 관리 실태를 설문 조사하였다. 결과: 시험착용 미용렌즈와 RGP 렌즈의 경우는 98% 이상의 안경사들이 렌즈 착용 전후 세척을 실시하고 있기 때문에 소비자들은 렌즈의 위생 상태를 신뢰하고 있는 것으로 나타났다. 시험착용 미용렌즈의 착용 전 세척은 생리식염수 38.5%, 전용 다목적 용액 40.5%, 생리식염수와 다목적 용액의 병행 사용 21%로 이루어지고 있었으며, 착용 후 세척은 생리식염수 13%, 다목적 용액 75%, 생리식염수와 다목적 용액의 병행이 12%로 이루어지고 있었다. 반면 시험착용 RGP 렌즈의 경우는 착용 전 세척에는 생리식염수가 28.5%, 전용 다목적 용액이 38.5%, 식염수와 다목적 용액 병행이 33%로 나타났으며, 착용 후 보관전 세척은 식염수가 2.5%, 다목적 용액이 70%, 다목적 용액 세척 후 식염수 세척은 27.5%를 차지하여 비교적 세척이 잘 이루어지고 있었다. 안경원에서 시험착용 미용렌즈의 세척은 주로 열흘에서 1개월을 주기로 이루어지는 것으로 나타냈고, 보관용기의 세척은 1 개월을 주기로 이루어졌다. 시험착용 RGP 렌즈의 세척주기는 주로 1개월 또는 2~3개월이었다. 시험착용렌즈 보관용기의 경우는 계면활성제를 이용하여 세척한 후 찬물로 헹구는 경우가 75% 이상으로 나타났다. 관리용품인 생리식염수의 보관기간은 주로 일주일로 나타났고, 다목적 용액의 보관기간은 주로 1개월이나 2~3개월로 나타나 안경원에서 렌즈 관리용액의 보관기간은 비교적 잘 지켜지고 있는 것으로 조사되었다. 결론: 안경원에서의 시험착용렌즈 및 관련 관리용품의 관리는 전반적으로 양호하게 이루지고 있었으나 생리식염수를 이용한 세척을 지양하고, 2주 이내의 세척주기와 뜨거운 물로의 렌즈 보관용기 헹굼이 추가적으로 강화된다면 국민의 눈 건강 증진과 더불어 안경사에 대한 더 높은 신뢰성 구축이 가능할 것이다.

슬관절 관절경 수술시 세척액 - 생리 식염수와 Lactated Ringer 용액의 비교 (Irrigation Solutions in the Knee Arthroscopy - Comparison with Normal Saline and Lactated Ringer's Solution)

  • 이우석;배인탁;허윤무;박원기;오병학;정환용
    • 대한관절경학회지
    • /
    • 제12권2호
    • /
    • pp.125-128
    • /
    • 2008
  • 목적: 슬관절 관절경하 반월상 연골 수술 시 생리 식염수와 Lactated Ringer 용액을 세척액으로 사용하여 임상적인 결과를 분석하고자 하였다. 대상 및 방법: 내측 반월상 연골 파열로 관절경하 내측 반월상 연골 부분 절제술을 시행한 64예를 대상으로 하였다. 제 I 군은 세척액으로 생리 식염수를 사용한 군으로, 제 II 군은 세척액으로 Lactated Ringer 용액을 사용한 군으로 분류 하였다. 수술 후 1일째의 visual analogue scale, 능동적 슬관절 굴곡 각도 및 슬관절 둘레의 증가율를 측정하여 비교 분석하였다. 결과: 수술 후 1일째의 visual analogue scale 및 능동적 슬관절 굴곡 각도의 비교는 통계학적으로는 두군 간에 유의성은 없었다. 그러나 수술 후 슬관절 둘레의 증가는 Lactated Ringer 용액을 사용한 군에서 생리 식염수를 사용한 군에 비해 통계학적으로 유의하게 적었다. 결론: 슬관절 반월상 연골 수술 시 Lactated Ringer 용액이 수술 후 부종의 감소에 생리 식염수보다 좋을 것으로 사료된다.

  • PDF

In vitro protoscolicidal effects of hypertonic glucose on protoscolices of hydatid cyst

  • Hosseini Seyed Vahid;Ghanbarzadeh Kurosh;Barzin Zahra;Sadjjadi Seyed Mahmoud;Tanideh Nader;Mehrabani Davood
    • Parasites, Hosts and Diseases
    • /
    • 제44권3호
    • /
    • pp.239-242
    • /
    • 2006
  • To evaluate the protoscolicidal effects of various concentrations of hypertonic glucose, live protoscolices of sheep were exposed to 10%, 15%, 25% and 50% glucose solutions. Cetrimide (0.5%), silver nitrate (0.5%) and hypertonic saline (20%) were used as positive controls, while physiological saline was used as a negative control. After 1, 2 and 5 min, the protoscolicidal effects were determined by 1 % eosin. A 25% glucose solution had no significant protoscolicidal effect. However, a 50% glucose solution revealed higher protoscolicidal effect than 0.5% silver nitrate but weaker effect than 0.5% cetrimide; the effect was comparable with that of 20% hypertonic saline. The results showed that hypertonic glucose solution is highly effective in killing protoscolices of Echinococcus granulosus in vitro.

Potentiostat를 이용한 타액에서의 아말감부식에 대한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY BY USING A POTENTIOSTAT ON THE CORROSION OF AMALGAMS IN SALIVA)

  • 손윤희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.534-548
    • /
    • 1994
  • The purpose of this study is to observe the corrosion characteristics of seven dental amalgams (CAULK FINE CUT, CAULK SPHERICAL, OPTALLOY II, DISPERSALLOY, HI VERALOY, TYTIN, VALIANT) through the anodic polarization curve obtained by using a potentiostat. After each amalgam alloy and Hg being triturated, the triturated mass was inserted into the cylindrical metal mold, and condensed by hydrolic pressure(160 kg/$cm^2$). Each specimen was removed from the metal mold. 24 hours after condensation, specimens were polished with the emery paper and stored at room temperature for 1 week. The anodic polarization curves were employed to compare the corrosion behaviours of the amalgam in 0.9% saline solution, Fusayama's artificial saliva, and stimulated parotid saliva at $37^{\circ}C$ with 3-electrode potentiostat. After the immersion of specimen in electrolyte for 1 hour, the potential scan was begun. The potential scan range was. -1700m V ~ + 400m V(vs. S. C. E) in the working electrode and the scan rate was 50m V /sec. The results were as follows, 1. The corrosion potential, the potential of anodic current peak, and transpassive potential in the stimulated parotid saliva shifted to more anodic direction than those in saline solution, and the current density in the stimulated parotid saliva was lower than that in saline solution. Those in Fusayama's artificial saliva was similar to those in stimulated parotid saliva. 2. The anodic polarization profiles in Fusayama's artificial saliva and stimulated parotid saliva indicated a region of slow slope current density, which is extending from the corrosion potential to the potential of anodic current peak, but that in 0.9% saline solution indicated no region of slow slope. 3. The corrosion potentials for CAULK FINE CUT, CAULK SPHERICAL, and OPT ALLOY II had the similarity in 0.9% saline solution, Fusayama's artificial saliva and stimulated parotid saliva, but those for high coper amalgam and VALIANT had no similarity. 4. The current density for TYTIN amalgam in stimulated parotid saliva was the lowest among the others. 5. As for current density, there was no significant difference between palladium enriched VALINAT and other high copper amalgams.

  • PDF