• Title/Summary/Keyword: Salient Type

Search Result 90, Processing Time 0.031 seconds

Design Considerations of 2-pole Synchronous Superconducting Rotating Machine (2극 초전도 동기기 설계법 고찰)

  • Baik, S.K.;Sohn, M.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.;Jo, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.865-867
    • /
    • 2001
  • Generally large synchronous rotating machines with 2 poles have more merits than the others with more than 2 poles Superconducting synchronous rotating machines also have the same tendency, but they have different structure from conventional ones because of no magnetic core inside of the rotor. As the result, design approaches of the superconducting field coils are also different, which would be classified into 2 types according to their coil shapes. The first one is race-track type and the other is saddle type Race-track type machines have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 2 poles. On the other hand saddle type machines correspond to conventional cylindrical generators with 2 poles used for large turbine system in power plants. In this paper several types of superconducting field coils are introduced for 2 pole superconducting machine design and then the feasibility of each type is considered. Moreover, based on the consideration. 1MVA superconducting generator(S.G.) with saddle type field coil is designed electromagnetically.

  • PDF

Influence of imperfectly bonded piezoelectric layer with irregularity on propagation of Love-type wave in a reinforced composite structure

  • Singh, Abhishek Kumar;Chaki, Mriganka Shekhar;Hazra, Bristi;Mahto, Shruti
    • Structural Engineering and Mechanics
    • /
    • v.62 no.3
    • /
    • pp.325-344
    • /
    • 2017
  • The present paper investigates the propagation of Love-type wave in a composite structure comprised of imperfectly bonded piezoelectric layer with lower fiber-reinforced half-space with rectangular shaped irregularity at the common interface. Closed-form expression of phase velocity of Love-type wave propagating in the composite structure has been deduced analytically for electrically open and short conditions. Some special cases of the problem have also been studied. It has been found that the obtained results are in well-agreement to the Classical Love wave equation. Significant effects of various parameters viz. irregularity parameter, flexibility imperfectness parameter and viscoelastic imperfectness parameter associated with complex common interface, dielectric constant and piezoelectric coefficient on phase velocity of Love-type wave has been reported. Numerical computations and graphical illustrations have been carried out to demonstrate the deduced results for various cases. Moreover, comparative study has been performed to unravel the effects of the presence of reinforcement and piezoelectricity in the composite structure and also to analyze the existence of irregularity and imperfectness at the common interface of composite structure in context of the present problem which serves as a salient feature of the present study.

Control of SRM with Modified C-dump Converter in Cooling System of Automobiles (Modified C-dump 컨버터를 이용한 자동차 냉각시스템 SRM 제어)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1297-1302
    • /
    • 2017
  • Recently, SRMs are used in automobiles for power assistant steering, accessory motion control and traction drives. Especially in the motion control and traction drives, safety and efficiency are of paramount importance. The paper describes the essential elements faced in designing and constructing driving circuits for a switched reluctance motor for automobiles. An important factor in the selection of a motor and a drive for industrial application is the cost. The switched reluctance motor(SRM) is a simple, low-cost, and robust motor suitable for variable-speed as well as servo-type applications. With relatively simple converter and control requirements, the SRM is gaining an increasing attention in the drive industry. This paper presents a modified C-dump converter for Switched Reluctance Motor (SRM) machine application in the cooling system of automobiles. The experiments are performed to verify the capability of applicate control method on 6/4 salient type SRM.

Design and Analysis of Above Knee Prosthetic Leg Using MR Damper (유동모드 MR 댐퍼가 구비된 대퇴의족의 설계 및 해석)

  • Park, Jinhyuk;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.165-171
    • /
    • 2016
  • A prosthetic knee for above-knee (AK) amputee is categorized into passive and active type. The passive prosthetic knee is generally made by elastic material. Although AK amputee can easily walk by using passive prosthetic leg, knee joint motions are not similar to ordinary persons. The active prosthetic leg can control the knee angle owing to the actuator and microprocessor. However, the active type is not cost-effective and the stability may be lost due to the malfunction of sensors. In order to resolve these disadvantages of passive and active type, a semi-active prosthetic knee which can control the knee angle is proposed in this work. The proposed semi-active one requires a less input energy but provides active type performance. In order to achieve this goal, in this work, a semi-active prosthetic knee using magneto-rheological (MR) damper for AK amputees is designed. The MR damper can support the weight of body by using less energy than actuator of active prosthetic. It can control knee angle by inducing the magnetic field at the time of stance phase. This salient characteristic is evaluated and presented in this work.

Attitudes and Preferences about Elderly Communal Housing-focused on developing Elderly Assisted Living in Korea- (노인공동생활주택에 대한 태도의 선호- 한국에서의 노인생활지원주택 개발 방향을 중심으로-)

  • 홍형옥
    • Journal of Families and Better Life
    • /
    • v.19 no.5
    • /
    • pp.147-166
    • /
    • 2001
  • The Purpose of this study was 1) to analyse the attitudes about Elderly Assisted Living (EAL) among urban Korean 2) to consider the policy implications for elderly communal housing. The research methods used were 1) social survey research with questionnaire to find attitudes and preferences about EAL among potential elderly client in Seoul, Korea 2) interpretative suggestion for appropriate policy implications to facilitate developing EAL in urban Korea. A questionnaire was used to find attitudes/preferences about EAL was adapted from the results of the review about communal housing in the UK. The survey was undertaken from September to October, 2000 in Seoul, Korea. Data was collected from 413 subjects and analysed using various statistical techniques. From the results, location should be differentiated into urban type and suburban type. The urban type would prefer around 5 stories multi-family house style with elevator and suburban type would prefer single detached house style with shared garde. The most preferred characteristics found by factor analysis were factor I named as communal facilities and environment(the items belong to factor I was neighbour environment, communal spaces and facilities, heating system, and elevator). The most important advantages of EAL were social activities and convenience. The most salient disadvantages of EAL were difficulty of family contact. The higher the occupational status and income, the lower the preference for the characteristics of EAL with a preference for finding appropriate living arrangements in present housing market. But the higher the educational level, the higher the degree of preference for the characteristics of EAL.

  • PDF

Hydroelastic analysis of a truss pontoon Mobile Offshore Base

  • Somansundar, S.;Selvam, R. Panneer;Karmakar, D.
    • Ocean Systems Engineering
    • /
    • v.9 no.4
    • /
    • pp.423-448
    • /
    • 2019
  • Very Large Floating Structures (VLFS) are one among the solution to pursue an environmentally friendly and sustainable technology in birthing land from the sea. VLFS are extra-large in size and mostly extra-long in span. VLFS may be classified into two broad categories, namely the pontoon type and semi-submersible type. The pontoon-type VLFS is a flat box structure floating on the sea surface and suitable in regions with lower sea state. The semi-submersible VLFS has a deck raised above the sea level and supported by columns which are connected to submerged pontoons and are subjected to less wave forces. These structures are very flexible compared to other kinds of offshore structures, and its elastic deformations are more important than their rigid body motions. This paper presents hydroelastic analysis carried out on an innovative VLFS called truss pontoon Mobile Offshore Base (MOB) platform concept proposed by Srinivasan and Sundaravadivelu (2013). The truss pontoon MOB is modelled and hydroelastic analysis is carried out using HYDRAN-XR* for regular 0° waves heading angle. Results are presented for variation of added mass and damping coefficients, diffraction and wave excitation forces, RAOs for translational, rotation and deformational modes and vertical displacement at salient sections with respect to wave periods.

Development of a Contact Type Height Sensor to Measure Ground Clearance of an Agricultural Tractor (농용 트랙터용 접촉식 지상고 측정 센서 개발)

  • Lee, Choong-Ho;Lee, Je-Yong;Lee, Sang-Sik
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • The tillage depth control system is one of the most salient control system of tractor implements. A contact-type height sensor was developed to measure ground clearance for the tillage depth control. The height sensor was fabricated in this study, and its efficacy in a tillage depth control system was evaluated. Experiments were conducted in order to determine both static and dynamic detection characteristics of the height sensor using soil bin system on the sampled soil (sandy loam, sand, clay loam). The results of the static detection characteristics showed that in the case, sandy loam soil despite and clay loam soil at a wet basis moisture content of 30%, large measurement errors were observed a due to penetration of a plastic puck into the sampled soil. The results of the dynamic detection characteristics showed that the height sensor detected the distance from the ground of sandy loam soil despite the uneven nature of the ground surface and the changes in traveling speed $1km/h{\sim}5km/h$ at a wet basis moisture content of 10%.

An Analysis on Rater Error in Holistic Scoring for Performance Assessments of Middle School Students' Science Investigation Activities (중학생 과학탐구활동 수행평가 시 총체적 채점에서 나타나는 채점자간 불일치 유형 분석)

  • Kim, Hyung-Jun;Yoo, June-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.1
    • /
    • pp.160-181
    • /
    • 2012
  • The purpose of this study is to understand raters' errors in rating performance assessments of science inquiry. For this, 60 middle school students performed scientific inquiry about sound propagation and 4 trained raters rated their activity sheets. Variance components estimation for the result of the generalizability analysis for the person, task, rater design, the variance components for rater, rater by person and rater by task are about 25%. Among 4 raters, 2 raters' severity is higher than the other two raters and their severities were stabilized. Four raters' rating agreed with each other in 51 cases among the 240 cases. Through the raters' conferences, the rater error types for 189 disagreed cases were identified as one of three types; different salience, severity, and overlooking. The error type 1, different salience, showed 38% of the disagreed cases. Salient task and salient assessment components are different among the raters. The error type 2, severity, showed 25% and the error type 3, overlooking showed 31%. The error type 2 seemed to have happened when the students responses were on the borders of two levels. Error type 3 seemed to have happened when raters overlooked some important part of students' responses because she or he immersed her or himself in one's own salience. To reduce the above rater errors, raters' conference in salience of task and assesment components are needed before performing the holistic scoring of complex tasks. Also raters need to recognize her/his severity and efforts to keep one's own severity. Multiple raters are needed to prevent the errors from being overlooked. The further studies in raters' tendencies and sources of different interpretations on the rubric are suggested.

Analysis on Lower Half Shapes of Middle Aged Women (중년여성 하반신의 유형분석)

  • 임희경;문명옥
    • Journal of the Korean Society of Costume
    • /
    • v.40
    • /
    • pp.95-107
    • /
    • 1998
  • The purpose of this research paper is to offer basic data for cloth design which is intended to apply appropriate shape and catacity to cloth. Followings are the analyzed result of investigation which was conducted to figure out the character of middle aged from 35 to 59 years old-women body especially in lower half of their body. 177 women took part in this investigation. 1. As a result of analyzed characters for middle aged women body shape, taking a side view of body, there are great variance in thickness coefficient which indicates the size of body. 2. According to a comparison result of early middle aged women body shape with late middle aged women body shape, the value in height items get shorter otherwise the value in thickness items get longer getting older. It means late middle aged women are relatively fat. 3. For the analysis of women body especially in lower half, 8 factors were used. They are as followings. Factor 1. Side thickness of lower half. Factor 2. Width of lower half. Factor 3. Height of lower half Factor 4. Droop of underbelly Factor 5. Salient rate of buttocks. Factor 6. Length of buttocks. Factor 7. Salient rate of underbelly. Factor 8. Droop of buttocks 4. Lower half shapes of middle aged women were divided into three groups and the character of each group are as followings. 〈Group 1〉65.0% of women who took part in this investigation have this type of body shape. They have long value in height items and thickness items. 〈Group 2〉16.4% of women who take part in this investigation were belonged to this group. The value in height items were not so different from group 1 but the thickness value are shorter than group 1. Women of group 2 have slime body shape. 〈Group 3〉18.6% of women were belonged to group 3. They show the shortest value in height items otherwise the longest value in thickness items. Therefore they are the smallest and the fattest group in this investigation.

  • PDF

Driving Characteristics of Single Phase SRM with Exciting Section (단상 SRM의 여자 구간에 따른 구동 특성)

  • Yeo, Sang-Kyom;Lee, Eun-Woong;Lee, Min-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.912-914
    • /
    • 2002
  • Single phase SRM(Switched Reluctance Motor) can not be started by itself and torque ripple is more generated than multi-phase SRM. But it is excited by single phase current and has very simple structure. Therefore it can be used in domestic appliance. Torque and speed of single phase SRM is controlled by adjusting exciting current and exciting section. Driver, which is composed with absolute encoder and DSP, is fabricated for control of exciting section on this paper. Then driving characteristics with exciting section is confirmed by using salient pole rotor type single phase SRM, which is fabricated in preceding research.

  • PDF