• 제목/요약/키워드: Safety test

검색결과 8,047건 처리시간 0.038초

CORRELATION BETWEEN SPF INDEX AND SAFETY MARKER IN SUNCREENS

  • Kim, Jong-Won;Suh, Soo-Kyung;Park, Ju-Young;Park, Chang-Won;Seo, Kyung-Won;Kim, Kyu-Bong;Kim, Kwang-Jin;Kim, Jae-Hee;Lee, Sun-Hee
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2002년도 Molecular and Cellular Response to Toxic Substances
    • /
    • pp.195-195
    • /
    • 2002
  • In recent years, the safety of sunscreens has been challenged based on the reports of its adverse effect on users; dermatitis, allergic contact dermatitis, photoallergic contact dermatitis. To investigate a correlation between sun protection factor (SPF) and the safety of sunscreens, we measured in vitro SPF index using homosalate as a standard and examined the toxicity tests on cosmetics; primary skin irritation tests, ocular irritation test, and skin sensitization test.(omitted)

  • PDF

Safety Requirements and Test Methods of a Radiofrequency Stimulator

  • Park, Sang-Geon
    • Journal of information and communication convergence engineering
    • /
    • 제14권3호
    • /
    • pp.191-199
    • /
    • 2016
  • In this study, we investigate the safety requirements and test methods of a radiofrequency stimulator. The main test items include controls of a minimum output, accommodation range, and output parameters that have been known as the safety requirements in conformity with international standards. As the test criteria for controlling the minimum output, an increase or decrease in a unit of 1 mA or 1 V or less was applied to the output amplitude regulator for both continuous and discontinuous control, and the output at the minimum setting was manipulated to not exceed 2% of the maximum setting. For controlling the output parameters, one of the representative test criteria states that the current limit of 250 mA should be equal to or less than 1,500 Hz. Consequently, when applying the radiofrequency stimulator on the human body, we need to ensure that the safety requirements conform to the international standards.

순간방전 시험에 의한 산업용 축전지 잔존수명 분석 (Analysis of Industrial Battery lifetime Using Instantaneous Discharge Test)

  • 김종민;방선배;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.123-124
    • /
    • 2008
  • Battery is one of the emergency power. Battery reliability is a very important to keep up the minimum of building capabilities in case of interruption of electric power. Instantaneous discharge test is carried out for measuring transient voltage change(${\Delta}V$) and internal instantaneous impedance(Z), and then it is compared with discharge test results for the estimating the battery capacity. As a result, it was confirmed that the voltage change(${\Delta}V$) and the instantaneous impedance of the batteries failed in actual discharge test were higher that those of the sound batteries. Such an instantaneous discharge test can be a diagnosis of battery sound.

  • PDF

CSG 재료의 강도특성에 관한 연구 (Strength Characteristics of CSG material)

  • 박한규;김기영;조성은;전제성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.619-626
    • /
    • 2005
  • This work aims at studing the stress-strain-strength behavior of an CSG(cemented sand and gravel) materials. An analysis of the mechanical behavior of the CSG is performed from the interpretation of results by unconfined compression test, large triaxial compression test in which the influence of both the degree of cementation and age. For CSG, It was concluded that the characterristics of compression are direct measurment of the degree of cementation and age. In addition, hyperbolic model is adopted to express the relation between elastic moduli and cementation, age, confined stress in small strain. The results of the test show that clear correlation with each other

  • PDF

본질안전방폭시스템 전원의 안정화에 관한 연구 (A study on stabilized power source in intrinsic safety system)

  • 이춘하;이창우
    • 한국가스학회지
    • /
    • 제8권1호
    • /
    • pp.18-24
    • /
    • 2004
  • 본 연구에서는 가연성가스가 존재하는 위험지역에서 사용되는 본질안전방폭형 전기기기가 외부로부터 직류전원을 공급받을 때 방폭 성능을 유지하기 위한 부품의 조건을 실험을 통하여 알아보았다. 따라서 제너다이오드의 역방향 특성을 실험하였으며, IEC형 불꽃점화시험기를 사용하여 제너다이오드와 저항으로 구성된 전원부의 점화특성효과를 실험하였다. 이 실험을 통하여 안정화된 전원부에서 사용되는 제너다이오드와 저항의 필요용량 값을 계산하고 본질안전시스템을 유지하기 위한 본질안전방폭형 전원공급방법을 설계하여 제시하였다.

  • PDF

자동차 휠 안전기준 개정 대응을 위한 내구 가혹도 검토 (A Study of the Endurance Severity for Automobile Wheel Safety Standard Revision)

  • 장진희;허성필
    • 자동차안전학회지
    • /
    • 제14권3호
    • /
    • pp.30-34
    • /
    • 2022
  • The CFT(Cornering Fatigue test) and RFT(Radial Fatigue Test) are tests for evaluating the endurance of the disc and rim region of the wheel. In recent, automobile wheel safety standards have been revised and the applied load and target life criteria are different from existing conditions. The verification evaluation of all wheels requires a lot of time and cost. In this study, the endurance severity of each test was compared through strain-life approach by selecting 4 steel and 8 aluminum wheels.

Evaluation of temperatures and flow areas of the Phebus Test FPT0

  • Koji Nishida;Naoki Sano;Seitaro Sakurai;Michio Murase
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.886-892
    • /
    • 2024
  • The cladding temperatures and axial mass distribution computed by MAAP5 were compared with their measured values in the test bundle of the Phebus Test FPT0. The computed cladding temperatures were in good agreed with the measured values in the pre-transient phase. In the transient heat-up phase, the computed temperatures were overestimated by the Baker-Just correlation in MAAP5, but the computed temperatures could simulate the subsequently measured values. The computed mass distribution in the axial direction was in qualitative agreement with the measured one for post-test fuel damage observations. The calculated flow areas of inner and outer regions in the test bundle were compared with the photographic observations. MAAP5 computed them at the height of 0.2 m where the molten pool formed was in qualitative agreement with the photographic observations. It was found that the remaining steam flow paths might be caused by the gas-liquid two-phase flow counter-current flow limitation.

화재 안전용 볼밸브의 열·구조 연성해석 (Thermal-structural Coupled Field Analysis for Fire Safety Type Ball Valve)

  • 김시범;이준호;이권희;전락원;도태완
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.28-32
    • /
    • 2011
  • The safety of transporting equipment in a cryogenic condition is one of important problems under the circumstances that the application weight of natural gas is gradually increasing. As a larger disaster may be generated by leakage of oil or gas from valves in case of fire occurrence of a ship, the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. to the design of ball valves satisfying fire safety test's specification(API607) to prevent this. In addition, the present research progressed fire safety tests and compared the test result with numerical analysis results. The Max stress by parts was confirmed through thermal analysis of major parts to evaluate safety. The fire safety test was progressed according to the regulation of API607.

Development of a Proficiency Test Specimen for Enumerating Escherichia coli in Molluscan Bivalve Shellfish

  • Kwon, Ji-Young;Song, Ki-Cheol;Son, Kwang-Tae;Yu, Hong-Sik;Kim, Poong-Ho;Shin, Soon-Bum;Mok, Jong-Soo;Lee, Ka-Jeong;Oh, Eun-Gyoung;Yoon, Ho-Dong;Lim, Keun-Sick;Kim, Young-Mog
    • Fisheries and Aquatic Sciences
    • /
    • 제14권3호
    • /
    • pp.226-229
    • /
    • 2011
  • This study was conducted to develop a proficiency test (PT) specimen for the enumeration of Escherichia coli, a sanitary indicative bacterium, in molluscan bivalve shellfish. The common mussel Mytilus edulis was chosen as a matrix for the PT specimen. Mussels were artificially bioaccumulated for approximately 3 h with E. coli culture. After determining the homogeneity of samples, samples were distributed to 17 participants involved in the proficiency testing program. The enumeration of E. coli was performed by the most probable number method of the American Public Health Association. Statistical evaluations of the results obtained from inter- and intra-laboratory variation indicated no significant differences in the accuracy of these techniques between participants, indicating z-scores of ${\leq}{\pm}2$ and suggesting that preparation of the PT specimen for enumerating E coli in shellfish was successful.