• Title/Summary/Keyword: Safety sensitive

Search Result 624, Processing Time 0.025 seconds

Enzyme Based Biosensors for Detection of Environmental Pollutants-A Review

  • Nigam, Vinod Kumar;Shukla, Pratyoosh
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.11
    • /
    • pp.1773-1781
    • /
    • 2015
  • Environmental security is one of the major concerns for the safety of living organisms from a number of harmful pollutants in the atmosphere. Different initiatives, legislative actions, as well as scientific and social concerns have been discussed and adopted to control and regulate the threats of environmental pollution, but it still remains a worldwide challenge. Therefore, there is a need for developing certain sensitive, rapid, and selective techniques that can detect and screen the pollutants for effective bioremediation processes. In this perspective, isolated enzymes or biological systems producing enzymes, as whole cells or in immobilized state, can be used as a source for detection, quantification, and degradation or transformation of pollutants to non-polluting compounds to restore the ecological balance. Biosensors are ideal for the detection and measurement of environmental pollution in a reliable, specific, and sensitive way. In this review, the current status of different types of microbial biosensors and mechanisms of detection of various environmental toxicants are discussed.

The humidity sensitive characteristics of $CaZrO_3$ ceramics ($CaZrO_3$ 세라믹스의 감습 특성)

  • Yuk, Jae-Ho;Kim, Yong-Woon
    • 전자공학회논문지 IE
    • /
    • v.43 no.3
    • /
    • pp.1-5
    • /
    • 2006
  • [ $CaZrO_3$ ] humidity sensors were prepared using the solid-state synthetic method and their humidity sensitive characteristics have been investigated. It was found that the impedance of the humidity sensors decreased with increasing relative humidity and the humidity sensitivity depended on the applied frequencies. The sensitivity of sensor is stable with heat treatment and a negligible hysteresis under cyclic humidity changes is shown, and the activation energy for electrical conduction is reduced with water adsorption.

Air pollution and hospital admissions for chronic obstructive pulmonary disease: are their potentially sensitive groups?

  • Tsai, Shang-Shyue;Yang, Ya-Hui;Liou, Saou-Hsing;Wu, Trong-Neng;Yang, Chun-Yuh
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.57-68
    • /
    • 2012
  • Recent studies showed that air pollution is a risk factor for hospitalization for chronic obstructive pulmonary disease (COPD). However, there is limited evidence to suggest which subpopulations are at higher risk from air pollution. This study was undertaken to examine the modifying effect of specific secondary diagnosis (including hypertension, diabetes, pneumonia, congestive heart failure) on the relationship between hospital admissions for COPD and ambient air pollutants concentrations. Hospital admissions for COPD and ambient air pollution data for Taipei were obtained for the period from 1999-2009. The relative risk of hospital admissions for COPD was estimated using a case-crossover approach. None of the secondary diagnosis we examined showed much evidence of effect modification.

Precise control flow protection based on source code (소스코드 기반의 정밀도 높은 실행 흐름 보호 기법)

  • Lee, JongHyup;Kim, Yong Seung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.5
    • /
    • pp.1159-1168
    • /
    • 2012
  • Control Flow Integrity(CFI) and Control Flow Locking(CFL) prevent unintended execution of software and provide integrity in control flow. Attackers, however, can still hijack program controls since CFI and CFL does not support fine-granularity, context-sensitive protection. In this paper, we propose a new CFI scheme, Source-code CFI(SCFI), to overcome the problems. SCFI provides context-sensitive locking for control flow. Thus, the proposed approach protects software against the attacks on the previous CFI and CFL schemes and improves safety.

Enhancing the Cybersecurity Checklist for Mobile Applications in DTx based on MITRE ATT&CK for Ensuring Privacy

  • Gee-hee Yun;Kyoung-jin Kim
    • Journal of Internet Computing and Services
    • /
    • v.24 no.4
    • /
    • pp.15-24
    • /
    • 2023
  • Digital therapeutics (DTx) are utilized to replace or supplement drug therapy to treat patients. DTx are developed as a mobile application for portability and convenience. The government requires security verification to be performed on digital medical devices that manage sensitive information during the transmission and storage of patient data. Although safety verification is included in the approval process for DTx, the cybersecurity checklist used as a reference does not reflect the characteristics of mobile applications. This poses the risk of potentially overlooking vulnerabilities during security verification. This study aims to address this issue by comparing and analyzing existing items based on the mobile tactics, techniques, and procedures of MITRE ATT&CK, which manages globally known and occurring vulnerabilities through regular updates. We identify 16 items that require improvement and expand the checklist to 29 items to propose improvement measures. The findings of this study may contribute to the safe development and advancement of DTx for managing sensitive patient information.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • Analytical Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

Rapid determination and quantification of hair-growth compounds in adulterated products by ultra HPLC coupled to quadrupole-orbitrap MS

  • Lee, Ji Hyun;Park, Han Na;Kang, Gihaeng;Kim, Nam Sook;Park, Seongsoo;Lee, Jongkook;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, a number of adulterated products, which are advertised as hair-growth enhancer have been emerged among those who suffer hair loss disease. For continuous control of illegal products, in this study, a rapid and sensitive method for simultaneous screening of 12 compounds that enhance hair-growth was established to protect public health by ultrahigh-performance liquid chromatography coupled to quadrupole-orbitrap mass spectrometry (UHPLC-Q-Orbitrap-MS). Fragmentation pathways of them were proposed based on $MS^2$ spectral data obtained using the established method. In this analysis, the LODs and LOQs ranged from 0.05 to 50 ng/mL and from 0.17 to 167 ng/mL, respectively. The square of the linear correlation coefficient ($R^2$) was determined as more than 0.995. The intra- and inter-assay accuracies were respective 88-112 % and 88-115 %. Their precision values were measured within 5 % (intra-day) and 10 % (inter-day). Mean recoveries of target compounds in adulterated products ranged from 84 to 115%. The relative standard deviation of stability was less than 12 % at $4^{\circ}C$ for 48 h. The method was employed to screen 14 dietary supplements advertised to be effective for the treatment of hair loss. Some of the products (~21 %) were proven to contain synthetic drugs that promote hair growth such as triaminodil, minoxidil, and finasteride.

A Study on the Software Fault Modes and Effect Analysis for Software Safety Evaluation (소프트웨어 안전성 평가를 위한 소프트웨어 고장 유형과 영향 분석에 관한 연구)

  • Kim, Myong-Hee;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.1
    • /
    • pp.115-130
    • /
    • 2012
  • These days, most of safety-critical systems, which are systems those failures or malfunction may result in death or serious injury to people, or loss or severe damage to social systems, or environmental harm, are being built of embedded software or loaded controlling software systems on computers, electrical and electronic components or devices. There are a lot kind of fault analysis methods to evaluate safety of the safety-critical systems equipped computers, electrical and electronic components or devices with software. However, the only assessment method to evaluate software safety of a safety-critical system is not enough to analysis properly on account of the various types and characteristic of software systems by progress of information technology. Therefore, this paper proposes the integrated evaluation method and carries out a case study for the software safety of safety-critical system which embedded or loaded software sizes are small and control response times are not sensitive by use of two security analysis methods which are Fault Tree Analysis (FTA) and Fault Modes and Effect Analysis (FMEA) for ubiquitous healthcare system.

Evaluation of the Anti-Tumor Effects of Paclitaxel-Encapsulated pH-Sensitive Micelles

  • Han, Jong-Kwon;Kim, Min-Sang;Lee, Doo-Sung;Kim, Yoo-Shin;Park, Rang-Woon;Kim, Kwang-Meyung;Kwon, Ick-Chan
    • Macromolecular Research
    • /
    • v.17 no.2
    • /
    • pp.99-103
    • /
    • 2009
  • We evaluated the efficacy of pH-sensitive micelles, formed by methoxy poly(ethylene glycol)-b-poly($\beta$)-amino ester) (PEG-PAE), as carriers for paclitaxel (PIX), a drug currently used to treat various cancers. PTX was successful encapsulated by a film hydration method. Micelles encapsulated more than 70% of the PTX and the size of the PTX-encapsulated micelles (PTX-PM) was less than 150 nm. In vitro experiments indicated that the micelles were unstable below pH 6.5. After encapsulation of PTX within the micelles, dynamic light scattering (DLS) studies indicated that low pH had a similar demicellization effect. An in vitro release study indicated that PTX was slowly released at pH 7.4 (normal body conditions) but rapidly released under weakly acidic conditions (pH 6.0). We demonstrated the safety of micelles from in vitro cytotoxicity tests on HeLa cells and the in vivo anti-tumor activity of PTX-PM in B16F 10 tumor-bearing mice. We concluded that these pH-sensitive micelles have potential as carriers for anti-cancer drugs.

A study on speed-sensitive vehicle brake light system using LED (LED를 이용한 속도 감응형 차량용 브레이크등 시스템)

  • Kim, Tae-Jin;Kim, Hyung-Jun;Park, Seong-Jun;Park, In-Soo;Park, Sung-Won;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.809-810
    • /
    • 2016
  • In this study, Speed-sensitive vehicle brake using the LED, When the driver presses the brake pedal, range step while being turned in connection taillights brake of the vehicle, such as speed-sensitive vehicle brake using the LED, It is turned on according to the deceleration of the vehicle to be series of points are displayed. The rear vehicle can prevent collision about an abrupt stop of preceding vehicle by perceiving deceleration state of preceding vehicle easier and faster. Also, if the inter-vehicle distance by using an ultrasonic sensor is closer than a certain distance, the emergency light turns on to convey the situation to the driver of the rear vehicle with a buzzer.

  • PDF