• Title/Summary/Keyword: Safety management and science

Search Result 5,508, Processing Time 0.03 seconds

Effects of Burnout on Job Stress and Ego-Resilience of Fire Officials (소방공무원의 직무스트레스와 자아탄력성에서 소진의 영향)

  • Lee, Hae-Young;Kim, Yeob-Rae
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.106-112
    • /
    • 2017
  • This study examined the burnout intermediates between Fire officials' job stress and Ego-resilience. The objective of this study is to suggest a policy that improves Fire officials' Ego-resilience. This survey was given to 365 fire officials in northern Gyeonggi-do region and the data was analyzed by correlation analysis and regression analysis using SPPS 22.0. The hypothesis is the Fire officials' burnout would be related to Ego-resilience and the effect on Fire officials' job stress regarding Ego-resilience is associated with burnout. The results of the study are that unstable work and inadequate reward affect the measure of burnout, which manifests as sarcasm and job efficacy and reduces the Fire officials' Ego-resilience that results in a positive pointing of the future, emotion control and interest. The meaning of policy is as follows: First, Fire officials need to be given confidence in their work stability. Second, they have to receive social or financial rewards. Third, they require a continuous supporting policy that solves their tension, physical and mental fatigue. Finally, developing diverse educational programs will be needed to promote their Ego-resilience.

Characteristics of the Han River Basin drought using SPEI and RDI (SPEI와 RDI를 이용한 한강유역 가뭄의 특징 분석)

  • Won, Kwang Jai;Chung, Eun-Sung;Lee, Bo-Ram;Sung, Jang Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • Standardized Precipitation Evapotranspiration Index (SPEI) considering evapotranspiration and precipitation is generally used to quantify the drought severity. Also, Reconnaissance Drought Index (RDI) has been frequently used in the arid regions which is suffering severe droughts, but drought analysis in association with RDI has been the focus of few studies in South Korea. Therefore, this study compared two meterological drought indices based on precipitation and evapotranspiration using Thornthwaite, Hargreaves, and Blaney-Criddle evaportranspiration calculation methods. Meteorological data of sixteen weather stations which are operated by Korea Meteorological Administration (KMA) were used to quantify drought and to compare characteristics of drought for the Han River Basin from 1992 to 2015. As a result, in case of Han River Basin, severe drought sharply increased in recent years. While the correlation coefficients are relatively high between the SPEIs and RDIs, the drought severity and year of severe drought are partially different. Therefore, it is necessary that RDI will be also measured to quantify severity and occurrence year of drought.

Analysis of Future Demand and Utilization of the Urban Meteorological Data for the Smart City (스마트시티를 위한 도시기상자료의 미래수요 및 활용가치 분석)

  • Kim, Seong-Gon;Kim, Seung Hee;Lim, Chul-Hee;Na, Seong-Kyun;Park, Sang Seo;Kim, Jaemin;Lee, Yun Gon
    • Atmosphere
    • /
    • v.31 no.2
    • /
    • pp.241-249
    • /
    • 2021
  • A smart city utilizes data collected from various sensors through the internet of things (IoT) and improves city operations across the urban area. Recently substantial research is underway to examine all aspects of data that requires for the smart city operation. Atmospheric data are an essential component for successful smart city implementation, including Urban Air Mobility (UAM), infrastructure planning, safety and convenience, and traffic management. Unfortunately, the current level of conventional atmospheric data does not meet the needs of the new city concept. New and innovative approaches to developing high spatiotemporal resolution of observational and modeling data, resolving the complex urban structure, are expected to support the future needs. The geographic information system (GIS) integrates the atmospheric data with the urban structure and offers information system enhancement. In this study we proposed the necessity and applicability of the high resolution urban meteorological dataset based on heavy fog cases in the smart city region (e.g., Sejong and Pusan) in Korea.

A Study on Digital Documentation of Precise Monitoring for Microscale Displacements within the Tomb of King Muryeong and the Royal Tombs in Gongju, Korea (공주 무령왕릉과 왕릉원 내부 미세변위 정밀모니터링을 위한 디지털 기록화 연구)

  • Choi, Il Kyu;Yang, Hye Ri;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.626-637
    • /
    • 2021
  • The tomb complex of the royal family from the period of the Ungjin Baekje Kingdom (475 to 538 AD) in Gongju, Korea, contains the tomb of King Muryeong and other royal tombs. After the excavation of the tomb of King Muryeong in 1971, these tombs were opened up to the public, without the establishment of systems for their safety, conservation and management. The tombs have consequently experienced rapid environmental changes and suffered various damages. In this study, specific vulnerable parts inside the tombs were selected for deviation analysis using 3D scanning, and 3D image models were constructed on this basis. Progressive displacement was identified in tomb No. 5, and basic data for future investigations was acquired from tomb No. 6 and the tomb of King Muryeong. In the deviation analysis for the southern plastered wall of tomb No. 5, the damage was not found to exceed the ranges of ±18 mm and ±2 mm. However, the lintel stone was found to be sagging by 0.32 mm on average, and the distance between the walls to have increased by 0.36 mm on average. Direct water seepage occurring in tomb No. 5 is considered to be increasing the damage within the tomb, such as the dropping and sagging of the lintel. The 3D image models constructed in this study will play an important role as baseline data for future research, and can be used to discuss a secure conservation scheme for the tombs through cross-validation with precise measurement monitoring.

The Relationship Between Fire-fighter's Resilience and PTSD (소방관의 회복탄력성과 PTSD 관계 분석)

  • Song, Young-Sun
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • This study is to improve fire-fighter's mental health by examining the relationship between fire-fighter's resilience and PTSD. The research question of the present study are follows. First, is there any relationship between fire-fighter's demographics and PTSD. Second, is there any relationship between fire-fighter's demographics and resilience. Third, is there any relationship between fire-fighter's resilience and PTSD. The instruments for collecting data of the study were KRO-53 and IES-R-K. These tests were administrated to all of the subjects of the study. The results of the study are as follows. First, fire-fighter's demographics except for department have an influence on PTSD. Second, fire-fighter's counselling experience has an influence on resilience. Third, fire-fighter's resilience has an influence on PTSD. Specially, self-regulation of resilience subtypes has an influence on PTSD. From the above results, The study proposed the following; to prevent PTSD, It is necessary to have specific working system, have specific counseling system, consider individual resilience in selecting fire-fighter and placing department.

Application for Fire Protection Regulation based on Risk-Informed and Performance-Based Analysis (위험도 및 성능기반 분석방법에 의한 원전 화재방호규정 적용 방안)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.65-70
    • /
    • 2006
  • From the beginning of the construction stage, the fire protection regulation for the nuclear power plants conforms to the design requirements for the acquisition of the license permit. This regulation is based on the plant status of the normal operation, but it is not enough to be used as an application standard for fire protection at the transient mode of the plant and the outage time for refueling as well as for the plant decommissioning. While the advanced fire protection requirement that has been developed in America recently suggests the performance-based requirement and management rule applicable to the overall life time of the plant, it simply represents the conceptual application. It means that it can not be treated as appropriate standards because it does not deal with the qualitative and quantitative approach in specific ways. By the way, with the use of the performance-based fire risk analysis, the dynamic behavior of the heat and smoke at the fire compartment of the nuclear power plants can be analyzed and the thermal effect to the safety-related equipment and cables can be evaluated as well. At this paper, it suggests the ways to change the applicable fire protection regulations and the required evaluation items for the fire risk resulted from the plant configuration change with an intent to introduce the state-of-the-art quantitative fire risk analysis technology at the domestic nuclear power plants.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Preliminary Feasibility Study for Water Resources Policy Effect Analysis Direction (수자원분야 예비타당성 조사 정책효과 분석 방향)

  • Seong, Yeonjeong;Choi, Seungan;Kwon, Hyun-Han;Jung, Younghun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.3
    • /
    • pp.1-16
    • /
    • 2021
  • Recently, large-scale projects are required in the water resources sector considering safety and publicitythe due to uncertainty of securing water resources and changes in the ecological environment by climate change. Among these large-scale projects, the projects that fall under the preliminary feasibility study are determined by comprehensive analysis based on economic analysis, policy analysis, and balanced regional development analysis. However, most of the results of the preliminary feasibility study showed a tendency to depend heavily on economic analysis. For this reason, projects in non-metropolitan areas sometimes fail in the preliminary feasibility study. To supplement this point, the Korea Development Institute revised the standard guidelines for preliminary feasibility studies for water resources sector projects that place a high weight on policy feasibility analysis. Therefore, the objective of this study is to analyze the cases of the preliminary feasibility study conducted previously and to suggest the direction of policy analysis in the preliminary feasibility study for water resources sector projects. For this, we analyze preliminary feasibility studies conducted for 18 years from 2002 to 2019, and suggest direction of policy analysis method using the benefit items not included in the economic analysis.

A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire (ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구)

  • Lee, Yeon-Ho;Lee, Joo-Hyung;Kim, Soo-Jin;Chon, Sung-Ho;Choi, Byoung-Chul;Oh, Seung-Ju;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.147-155
    • /
    • 2020
  • This paper presents a study on the development of a fire extinguishing agent and extinguishing system for an energy storage system (ESS) fire. The fire extinguishing agent designed to extinguish an ESS fire is a highly permeable fire extinguisher that reduces the surface tension and viscosity while bringing about cooling action. This is the main extinguishing effect of this type of wetting agent, which displays the characteristics of fire extinguishing agents used for penetrating the battery cells inside the ESS module. For the fire extinguishing system, a local application system was designed to suppress fire on a rack-by-rack basis. A 360° rotating nozzle was inserted into the rear hall of the ESS module, and general nozzles were installed in the rack to maximize the fire extinguishing effect. The fire extinguishing agent was strongly discharged by virtue of the gas release pressure. Experiments on fire suppression performance with ESS module 1 unit and module 3 units showed that all visible flames were extinguished in 8 s and 9 s, respectively, by the fire extinguishing agent. In addition, based on confirming reignition for 600 s after the fire extinguishing agent was exhausted, it was confirmed that the ESS fire was completely extinguished without reignition in all fire suppression performance experiments.

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.