• Title/Summary/Keyword: Safety PLC

Search Result 84, Processing Time 0.034 seconds

RPS Periodic Testing Method for Reliability and Availability (신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발)

  • Park, Joo-Hyun;Lee, Dong-Young;Lee, Seong-Jin;Song, Deok-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Optimal Scheduling of Multi-product Batch Process for Common Intermediate Storage Policy; A Model for Batch Process Automation (다품종용 회분식 공정에서의 중간 저장 탱크 공유를 위한 최적 생산계획 ; 회분식 조업의 자동화 모델)

  • 정재학;이인범;양대륙;장근수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.303-308
    • /
    • 1992
  • In this study, we propose a shared storage system which is more efficient policy than MIS(Mixed Intermediate Storage) policy for relatively rare storage system and can be called CIS(Common Intermediate Storage) policy. Using this strategy, we develop a new completion time algorithm and apply it to two kinds of optimal or near optimal scheduling method; combinatorial search and simulated annealing method. We also extend this strategy to other storage policy, for example MIS policy, with PLC(Programmable Logic Controller) logic and on/off action of electronic valves. It thus can be accepted as a basic form of FMS(Flexible Manufacturing System) for operating various storage policies. Finally we suggest the interlocking block to compansate for the shortcoming of CIS policy, i.e, complication of operation and safety, resulting in a basic batch process automation mode.

  • PDF

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF

Development of Operation Control System for the 3 Ton/Day Bench Scale Gasifier (3톤/일 석탄가스화 반응장치의 운전제어 시스템 개발)

  • 김대규;윤용승;장휴정;유진열;홍만화
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.64-77
    • /
    • 1994
  • 현재 건설중인 3톤/일 규모의 석탄가스화기 운전제어를 위한 콘트롤시스템은 각종 하드웨어와 소프트웨어로 구성된다. 하드웨어는 운전자가 접하게되는 컴퓨터 화면(Operator Console), 운전 제어용 판넬(Hardwired Console), 본 시스템의 핵심인 콘트롤러(PLC; Programmable Logic Controller), 폭발성가스와 분진이 있는 환경하에서의 안전운전을 위한 본질안전 장벽(Intrinsic Safety Barrier) 및 운전정보 수집과 운전 제어를 위한 각종 전/계장품(Field Instrument) 등으로 구성된다. 본 시스템에 포함되는 소프트웨어에는 운전자와 콘트롤러간의 통신을 위한 운전제어화면(GUI;Graphical User Interface), 전체적인 제어를 위한 콘트롤로직(Control Logic)등이있다. 한편 각종 펌프 및 보일러 등 보조설비로의 전기공급을 위한 MCC(Motor Control Center)도 하나의 구성원이 된다. 본 논문은 석탄가스화 반응기의 운전에 관한 전반적인 검토와 콘트롤시스템을 구성하는 각 요소와 각각의 특징 및 그 개발 현황에 대한 검토를 그 내용으로 한다. 본 연구과제를 통해 제작, 설치될 석탄가스화기는 차세대 발전 시스템으로 주목을 받고있는 석탄가스화 복합발전시스템의 핵심부분으로, 본 반응장치의 제어에 관한 경험은 상용 규모의 석탄가스화 반응기에도 유사하게 적용될 것으로 기대된다.

  • PDF

A Study about Preventing Improper Working of Equipment on ATS System by Signaling Equipment (신호장치에 의한 ATS 신호장치 오동작 방지에 대한 연구)

  • Ko, Young-Hwan;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.579-587
    • /
    • 2008
  • Promotion of the line no.2 in Seoul Metro was changing from the existing signaling facilities for ATS(Automatic Train Stop) vehicles to the up-to-date signaling facilities for ATO(Automatic Train Operation). But, in consequence of conducting a trial run after being equipped with the ATO signaling facilities, the matter related to mix-operation with the existing ATS signaling facilities appeared. The operation of the existing ATS signaling system in combination with the ATO signaling system has made improper working related to frequency recognition of the ATS On-board Computerized Equipment. This obstructs operation of a working ATS vehicle. That is, as barring operation of an ATS vehicle that should proceed, it may make the proceeding ATS vehicle stop suddenly and after all, it will cause safety concerns. In this paper, we designed a wayside track occupancy detector that previously prevents improper working related to frequency recognition of the ATS On-board Computerized Equipment by gripping classification and working processes of operating trains throughout transmission of local signaling information from the existing facilities, which does not need to change or replace the existing signaling facilities. Furthermore, we described general characteristics of the wayside track occupancy detector and modeled the IFC(InterFace Contrivance) device and the logical circuit recognizing signal information. Then, we made an application program of PLC(programmable Logic Computer) based on the stated model. We, in relation to data transfer method, used the frame in TCP/IP transfer mode as the standard, and we demonstrated that ATO transmission frequency is intercepted.

  • PDF

Digital Asset Analysis Methodology against Cyber Threat to Instrumentation and Control System in Nuclear Power Plants (원자력발전소의 디지털계측제어시스템의 사이버보안을 위한 디지털 자산분석 방법)

  • Koo, In-Soo;Kim, Kwan-Woong;Hong, Seok-Boong;Park, Geun-Ok;Park, Jae-Yoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.839-847
    • /
    • 2011
  • Instrumentation & Control(I&C) System in NPP(Nuclear Power Plant) plays a important role as the brain of human being, it performs protecting, controling and monitoring safety operation of NPP. Recently, the I&C system is digitalized as digital technology such as PLC, DSP, FPGA. The different aspect of digital system which use digital communication to analog system is that it has potential vulnerability to cyber threat in nature. Possibility that digital I&C system is defected by cyber attack is increasing day by day. The result of cyber attack can be adverse effect to safety function in NPP. Therefore, I&C system required cyber security counter-measures that protect themselves from cyber threat efficiently and also cyber security design should be taken into consideration at concept stage in I&C system development process. In this study, we proposed the digital asset analysis method for cyber security assessment of I&C system design in NPP and we performed digital asset analysis of I&C system by using the proposed method.

Development of Reefer Container Real-time Management System (실시간 냉동컨테이너 관리 시스템 개발)

  • Choi, Sung-Pill;Jung, Jun-Woo;Moon, Young-Sik;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim;Lee, Eun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2917-2923
    • /
    • 2015
  • In spite of a recent trend of container ships becoming larger in size, the current circumstance is that managing reefer containers marine transportation is being mostly dependent upon manpower. Particularly, in the case of bad weather or nighttime, reefer containers are not being monitored due to lack of safety device. For the purpose of reducing such risk, IMO is recommending a system using PLC but the system is not being used. In addition, they are still relying on manpower for control and reliability of freight in transit is decreasing due to lack of information during marine transportation for every subject related to freight as well as shipper. Accordingly, the purpose of this paper is to propose a real-time reefer container management system to effectively control all reefer containers widely being used across the world.

Development of Real-time based Hardware-In-Loop Simulator for performance evaluation of wind turbine control system (풍력발전기 제어시스템 성능평가를 위한 실시간 처리 기반의 Hardware-In-Loop 시뮬레이터 개발)

  • Kim, Dae-Jin;Ryu, Kyung-Sang;Kim, Byungki;Jang, Moon-Seok;Ko, Hee-Sang;Yoo, Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.794-805
    • /
    • 2017
  • This paper proposes a Hardware-In-Loop(HIL) Simulator for a Wind Turbine and an operational control algorithm to evaluate the performance of a wind turbine control system. It provides not only for the validation of the control logics, safety functions and H/W failure, but also for the high reliability of the wind turbines (by reducing/and the reduction of the operating expense(OPEX) through performance evaluation tests with complex scenarios. On the other hand, the proposed simulator uses MATLAB, CODER, and the PLC library to operate in synchronization with the hardware, and a real-time processing-based wind turbine module including a dynamic model and control system, wind module, grid module and host PC to manage the HIL-simulator. Several experiments were carried out under the above concept to verify the effectiveness of the proposed WT HIL-simulator.

A Study on Smart Ground Resistance Measurement Technology Based on Aduino (아두이노 기반 IT융합 스마트 대지저항 측정 기술 연구)

  • Kim, Hong Yong
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.684-693
    • /
    • 2021
  • Purpose: The purpose is to establish a safe facility environment from abnormal voltages such as lightning by developing a smart land resistance measuring device that can acquire real-time land resistance data using Arduino. Method: This paper studied design models and application cases by developing a land resistance acquisition and analysis system with Arduino and a power line communication (PLC) system. Some sites in the wind power generation complex in Gyeongsangnam-do were selected as test beds, and real-time land resistance data applied with new technologies were obtained. The electrode arrangement adopted a smart electrode arrangement using a combination of a Wenner four electrode arrangement and a Schlumberger electrode arrangement. Result: First, the characteristic of this technology is that the depth of smart multi-electrodes is organized differently to reduce the error range of the acquired data even in the stratigraphic structure with specificity between floors. Second, IT convergence technology was applied to enable real-time transmission and reception of information on land resistance data acquired from smart ground electrodes through the Internet of Things. Finally, it is possible to establish a regular management system and analyze big data accumulated in the server to check the trend of changes in various elements, and to model the optimal ground algorithm and ground system design for the IT convergence environment. Conclusion: This technology will reduce surge damage caused by lightning on urban infrastructure underlying the 4th industrial era and design an optimized ground system model to protect the safety and life of users. It is also expected to secure intellectual property rights of pure domestic technology to create jobs and revitalize our industry, which has been stagnant as a pandemic in the post-COVID-19 era.