• 제목/요약/키워드: Safety Measure

검색결과 1,806건 처리시간 0.029초

체감 산업안전 평가지수 개발과 그 응용에 대한 연구 (Development of Effective Industrial Safety Index and Application)

  • 김유창;김의창
    • 산업공학
    • /
    • 제14권1호
    • /
    • pp.106-110
    • /
    • 2001
  • The importance of development of occupational safety index is truly great. It will contribute to the wise direction of safety program. In present, frequency and severity ratios were the standard measure. These terms express the incidence of major injuries and severity of the major injuries experience, each with relation to the employee-hours of work exposure during the period that is measured. But these measure don't expressed the dangerous feeling degree of worker. In this study, Effective Industrial Safety Index(EISI) was developed using dangerous feeling degree of worker, frequency of injuries, and severity of injury. EISI can be used as an aid for effective safety management in workplace.

  • PDF

산업용 필드버스 기반의 안전 펜스 시스템 개발 및 성능 평가 (Implementation and Performance Evaluation of Safety Fence System Based on Industrial Fieldbus)

  • 이승용;임선
    • 대한임베디드공학회논문지
    • /
    • 제14권1호
    • /
    • pp.43-49
    • /
    • 2019
  • Recently, the importance of industrial fieldbus has been highlighted since the emergence of Industry 4.0. In particular, the Ethernet-based fieldbus protocol is actively used in automation systems. This paper proposes a safety fence system based on EtherCAT, a type of Ethernet-based fieldbus, to measure external loads. In order to measure the external loads, a force sensor was connected to an EtherCAT slave that transmits the sensor data to an EtherCAT master in real-time. The master ultimately controls the angle of the safety fence when it detects danger based on the given data. In the future, more effiecient safety fence system will be developed by using a HMI system to communicate with the EtherCAT master to manage safety and by employing multiple sensors to increase the accuracy of the fence system.

풍동실험을 통한 사장교의 내풍 안전성 검토 (Wind-Resistant Safety Reviews of Cable-Stayed Bridge by Wind Tunnel Tests)

  • 허택녕
    • 한국산업융합학회 논문집
    • /
    • 제23권4_2호
    • /
    • pp.637-644
    • /
    • 2020
  • Because suicide accidents sometimes were happened in grand bridges over rivers or sea water recently, it will be necessary that prevention measures be made preparation in advance from now on. Additional safety facilities must be needed in addition to existing safety facilities in such a way as this prevention measure. In order to make cable-stayed bridge safe on wind for additional safety facilities, main girder models with added safety facilities for wind-tunnel tests was made, and wind tunnel experiments was carried out to measure aerodynamic force coefficients. Also, wind-resistant analyses of 3D cable-stayed bridge were performed on the basis of wind-tunnel test results. From the wind experiments, force coefficients of main girder with added safety facilities were assessed, and it is known that there are little possibility of galloping and rotation of steel main girder. Finally, from the wind resistant analyses, it was concluded that wind-resistant safety of cable-stayed bridge was secured on wind speed 60.6m/sec.

Analysis of evacuation time for New publicly used establishments according to whether safety facilities, etc. are installed

  • Hong-Sang Lee;Ha-Sung, Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권2호
    • /
    • pp.49-59
    • /
    • 2023
  • In accordance with the revision of "Special act on the safety control of publicly used establishments", this study is aim to measure the change in evacuation time due to whether safety facilities, etc. are installed of a room escape cafe business and kids cafe business(hereinafter referred to as "New publicly used establishments"), which were added as new targets of the publicly used business from June 8, 2022. In the case of new publicly used establishments or publicly used establishments whose owners are changed after the revision of the relevant laws, safety facilities, etc. are installed and maintained under the "Special act on the safety control of publicly used establishments", but in the case of existing businesses that have been operating even before the revision of the law, the business continues without safety facilities, etc. installed because the revised law is not retroactively applied. The purpose of this study is to compare and analyze the change in evacuation time by measuring the evacuation time to operating before the revision of the law to simulate evacuation at existing new publicly used establishments without safety facilities, etc. and measure the evacuation time at new publicly used establishments with safety facilities after the revision of the law

Local Dynamic Stability Associated with Load Carrying

  • Liu, Jian;Lockhart, Thurmon E.
    • Safety and Health at Work
    • /
    • 제4권1호
    • /
    • pp.46-51
    • /
    • 2013
  • Objectives: Load carrying tasks are recognized as one of the primary occupational factors leading to slip and fall injuries. Nevertheless, the mechanisms associated with load carrying and walking stability remain illusive. The objective of the current study was to apply local dynamic stability measure in walking while carrying a load, and to investigate the possible adaptive gait stability changes. Methods: Current study involved 25 young adults in a biomechanics research laboratory. One tri-axial accelerometer was used to measure three-dimensional low back acceleration during continuous treadmill walking. Local dynamic stability was quantified by the maximum Lyapunov exponent (maxLE) from a nonlinear dynamics approach. Results: Long term maxLE was found to be significant higher under load condition than no-load condition in all three reference axes, indicating the declined local dynamic stability associated with load carrying. Conclusion: Current study confirmed the sensitivity of local dynamic stability measure in load carrying situation. It was concluded that load carrying tasks were associated with declined local dynamic stability, which may result in increased risk of fall accident. This finding has implications in preventing fall accidents associated with occupational load carrying.

한국어 퍼지 언어변수를 이용한 리스크 평가의 논리적 일관성 (Logical Consistency in Risk Assessment using the Korean Fuzzy Linguistic Variables)

  • 임현교;변상훈
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.120-125
    • /
    • 2016
  • Usually, a risk can be expressed as a product of likelihood and consequence of a hazard factor. Therefore, conventional risk assessment is carried out by frequency analysis and severity analysis, in turns. However, it is well known that intuitive thinking is another excellent way of thinking of human beings. This study aimed to confirm whether there exist any difference in risk assessment results derived by two different procedures - intuitive and analytical. Thus, the present study showed 10 different illustrations to 30 undergraduate students. Their responses were organized as fuzzy membership functions, and summarized as risk assessments, and compared. The results were also verified with the help of statistical hypothesis testing, which showed no significant difference. On the contrary, however, similarity measure used in fuzzy set theory was not credible as anticipated. Many cases failed to satisfy statistical hypothesis even with similarity measure higher than 0.60 so that only a trend could be accepted. In addition, a subject showed a somewhat consistent logical discrepancy in his response, which implied the necessity of sincere analysis in fuzzy formulations.

퍼지이론을 이용한 3상 2회선 불평형 송전선로에서의 전자계에 대한 인체 위험 가능성평가 (Assessment of Possibility on the Human Risk for the Electromagnetic Field of Unbalanced Two Coupled Three-phase Transmission Line Using Fuzzy Theory)

  • 김상철;김두현
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.22-28
    • /
    • 2006
  • This paper presents assessment of possibility on the human risk for the electromagnetic field of unbalanced two coupled three-phase transmission line using fuzzy theory. Three phase load flow program was developed which employed a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. As the results of case study, in case of 345[kV] T/L, the electric field intensity was 10.9540[kV/m], magnetic field intensity was 0.2567[G] in severest case. The results showed that the membership of a proposition fuzzy '10.9540 [kV/m] is hazardous' is 0.6349. As the analytic results using the fuzzy qualifier term, the membership in case of very false is 0.1379 and fairly false is 0.6124, respectively. In assessment of fuzzy measure possibility for the electromagnetic field, this paper used probability of fuzzy arid measure of fuzziness technique.

화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구 (A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession)

  • 정병선;김응식;박종열
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

Application of Discrimination Information (Cross Entropy) as Information-theoretic Measure to Safety Assessment in Manufacturing Processes

  • Choi, Gi-Heung;Ryu, Boo-Hyung
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.1-5
    • /
    • 2005
  • Design of manufacturing process, in general, facilitates the creation of new process that may potentially harm the workers. Design of safety-guaranteed manufacturing process is, therefore, very important since it determines the ultimate outcomes of manufacturing activities involving safety of workers. This study discusses application of discrimination information (cross entropy) to safety assessment of manufacturing processes. The idea is based on the general principles of design and their applications. An example of Cartesian robotic movement is given.