• Title/Summary/Keyword: Safety Margin

Search Result 496, Processing Time 0.024 seconds

The Sensitivity Analysis for LRV Opening Pressure in CANDU (중수로 원전에서 액체방출밸브의 개방압력에 대한 민감도평가)

  • Kim, S.M.;Kho, D.W.;You, S.C.;Kim, J.H.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.40-44
    • /
    • 2015
  • Sensitivity on the reactor safety was evaluated for the safety margin and time delay applied to the opening pressure of liquid relief valve(LRV) of the primary heat transport system(PHTS) in the pressurized heavy water reactor(PHWR) type nuclear power plant. Since the LRV is the pressure boundary for the PHTS in the safety analysis, the operating of LRV has a significant effect on the safety analysis results. Therefore it is required during the regulatory review of Wolsong Unit 1 safety analysis to find the safety effect of the application of safety margin and time delay to the LRV opening pressure for the safety analysis of PHTS pressurizing events.

Tests of Factor Effect Using Saturated Design in $K^n$ Factorial Design ($K^n$ 요인배치법에서 포화실험에 의한 요인효과의 검정)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.295-299
    • /
    • 2008
  • This paper discusses tests of factor effect or contrast by the use of saturated design $k^n$ factorial design. The nine nonparametric rank measures in normality test using normal probability pot are proposed. Length's PSE(Pseduo Standard Error) test [4] which relies on the concept of effect sparsity is also introduced and extended to the margin of error(ME) and Simultaneous margin of error(SME).

  • PDF

Statistical analysis of S-N type environmental fatigue data of Ni-base alloy welds using weibull distribution

  • Jae Phil Park;Junhyuk Ham;Subhasish Mohanty;Dayu Fajrul Falaakh;Ji Hyun Kim;Chi Bum Bahn
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1924-1934
    • /
    • 2023
  • In this study, the probabilistic fatigue life model for Ni-base alloys was developed based on the Weibull distribution using statistical analysis of fatigue data reported in NUREG/CR-6909 and the new fatigue data of Alloy 52M/152 and 82/182. The developed Weibull model can consider right-censored data (i.e., non-failed data) and quantify the improved safety (or reliability) based on the level of failure probability. The overall margin in the current fatigue design limit model (ASME design curve + NUREG/CR-6909 Fen model) is similar to that of the Weibull model with a cumulative failure probability of approximately 2.5%. The margin in the current fatigue design limit model demonstrated inconsistencies for the Ni-base alloy weld data, whereas the Weibull model showed a consistent margin. Therefore, the Weibull model can systematically mitigate the excessive safety margin.

Primary cutaneous mucinous carcinoma in a periorbital lesion: two case reports and literature review

  • Jun Woo Kim;Sung Eun Kim
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.2
    • /
    • pp.90-94
    • /
    • 2024
  • Primary cutaneous mucinous carcinoma (PCMC) is a rare malignancy of the sweat glands that most commonly affects the periorbital area. It is characterized by slow growth over a prolonged period, and its morphology can be easily confused with a benign tumor, such as an epidermal cyst. Consequently, many patients experience recurrence after undergoing multiple resections. However, there are few reports concerning the surgical management of PCMC. We present two cases of PCMC originating in the periorbital area. The first case involved a 76-year-old man with a mass measuring 3.0×1.5 cm that had been increasing in size. The second case was a 61-year-old man with two masses, each measuring 1.0×1.0 cm, that were also growing. Both patients underwent wide excision with a 5-mm safety margin, which was determined based on the widest view of the cross-section of the mass on the magnetic resonance imaging. Subsequently, based on the intraoperative frozen biopsy results, both patients underwent additional excision with a 5-mm safety margin in only one direction. This report shows that, when determining the surgical margin of PCMC in periorbital area, employing imaging modalities and intraoperative frozen biopsies can be helpful for narrowing the surgical margin.

The Study of Improvement in Reactor Thermal Power Measurement Method using KALMAN FILTER (KALMAN FILTER를 이용한 원자로 열출력측정 방법개선에 관한 고찰)

  • 정남교
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.5
    • /
    • pp.82-95
    • /
    • 1997
  • A Study of Improvement in Reactor Thermal Power Measurement Method using Kalman Filter. The objectives of the safety analysis of nuclear power plants are to maintain the surface temperature of fuel and fuel cladding within limit value in case of Loss of Coolant accident (LOCA) so that it ensures the safety and reliability of nuclear power plants. The new technique evaluating the reactor power and improvement of existing plant system increase the safety margin of nuclear power plant operation, and accordingly, economic effect will be anticipated. Hereby, 1 would like to introduce reactor power measurement method using Kalman filter that enables to calculate the reactor power more precisely combining the parameters, for example, turbine output as the 1 st stage pressure of high pressure turbine, and reactor power using energy equilibrium relation. It is expected that the new technique will enhance the accuracy of measurement of reactor power and maintain the reliability of nuclear power operation by increasing operational safety margin, and gain the economic benefit

  • PDF

SENSITIVITY ANALYSES OF THE USE OF DIFFERENT NEUTRON ABSORBERS ON THE MAIN SAFETY CORE PARAMETERS IN MTR TYPE RESEARCH REACTOR

  • Kamyab, Raheleh
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.513-520
    • /
    • 2014
  • In this paper, three types of operational and industrial absorbers used at research reactors, including Ag-In-Cd alloy, $B_4C$, and Hf are selected for sensitivity analyses. Their integral effects on the main neutronic core parameters important to safety issues are investigated. These parameters are core excess reactivity, shutdown margin, total reactivity worth of control rods, thermal neutron flux, power density distribution, and Power Peaking Factor (PPF). The IAEA 10 MW benchmark core is selected as the case study to verify calculations. A two-dimensional, three-group diffusion model is selected for core calculations. The well-known WIMS-D4 and CITATION reactor codes are used to carry out these calculations. It is found that the largest shutdown margin is gained using the $B_4C$; also the lowest PPF is gained using the Ag-In-Cd alloy. The maximum point power densities belong to the inside fuel regions surrounding the central flux trap (irradiation position), surrounded by control fuel elements, and the peripheral fuel elements beside the graphite reflectors. The greatest and least fluctuation of the point power densities are gained by using $B_4C$ and Ag-In-Cd alloy, respectively.

A Study on the Evaluation of the Pipe Fracture Characteristic (실배관 파괴특성 평가에 관한 연구)

  • Park Jae-Sil;Kim Young-Jin;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.

A Steady-State Margin Comparison between Analog and Digital Protection Systems (아날로그와 디지탈 보호계통의 정상 상태 여유도 비교)

  • Auh, Geun-Sun;Hwang, Dae-Hyun;Kim, Si-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.45-57
    • /
    • 1990
  • A steady-state margin comparison study was performed between analog and digital protection systems. The systems compared are the thermal overpower and overtemperature delta T system of Westinghouse, and Core Protection Calculator System of Combustion Engineering, Inc. No dynamic offset was considered to eliminate the margin differences by different safety analysis methodologies. The result shows that the digital protection system has about 30% more rated power margin than the analog system in protecting against the fuel rod centerline melting. The digital protection system is shown to have almost same margin with the analog protection system in preventing the DNB at EOC (End of Cycle) even if the digital protection system has about 10% more margin at BOC(Beginning of Cycle).

  • PDF

Comparison of vessel failure probabilities during PTS for Korean nuclear power plants

  • Jhung, M.J.;Choi, Y.H.;Chang, Y.S.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.3
    • /
    • pp.257-265
    • /
    • 2011
  • Plant-specific analyses of 5 types of domestic reactors in Korea are performed to assure the structural integrity of the reactor pressure vessel (RPV) during transients which are expected to initiate pressurized thermal shock (PTS) events. The failure probability of the RPV due to PTS is obtained by performing probabilistic fracture mechanics analysis. The through-wall cracking frequency is calculated and compared to the acceptance criterion. Considering the fluence at the end of life expected by surveillance test, the sufficient safety margin is expected for the structural integrity of all reactor pressure vessels except for the oldest one during the pressurized thermal shock events. If the flaw with aspect ratio of 1/12 is considered to eliminate the conservatism, the acceptance criteria is not exceeded for all plants until the fluence level of $8{\times}10^{19}\;n/cm^2$, generating sufficient margin beyond the design life.

Stress and Modal Analysis for the Rotor System of a Medical Centrifuge using Finite Element Method (유한요소법을 이용한 의료용 원심분리기 로터의 응력 및 고유치 해석)

  • Kim, Sung-Min;Yang, In-Chul;Kim, Do-Gyoon;Kim, Hak-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.78-85
    • /
    • 2007
  • In this study, we performed finite element analysis for the design of a medical centrifuge and two-types of centrifuge were compared with each other. The types of centrifuge are 2-arm straight type and 3-arm type. Structural analysis was done with respect to the change of the rotational speed of the rotor of a centrifuge. When the rotor of centrifuge was rotated, the von Mises stress of 2-arm straight type-rotor was compared with the von Mises stress of 3-arm type. The margin of safety was estimated from the result. We found the critical speed of centrifuge from the campbell diagram by modal analysis.