• Title/Summary/Keyword: Safety Device

Search Result 1,781, Processing Time 0.034 seconds

A Study on the Short-circuit Protection System for Learning Teaching Instruction Using Incandescent Light Bulb (백열전구를 이용한 학습 교구용 단락보호장치에 대한 고찰)

  • Hong-yong Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.844-850
    • /
    • 2023
  • Purpose: This paper is about the development of a short-circuit protection power supply device using incandescent bulbs and its application for educational materials. This article, which considers electrical safety and energy conservation at the same time, has many kinds of potential applications for both educational and industrial areas. The above mentioned short-circuit protection power supply device using incandescent bulbs enhances safety and efficiency compared to normal current power supply devices. Additionally, as an educational materials, it can be used for electric safety training, and provides practical electrical safety knowledge on our actual life. Method: Using incandescent bulbs, design new type of short-circuit protection power supply device, and through verifying the function and safety of the device, make new type device, and applying it for an educational tool. Conclusion: This study is to develop new type of power supply device, and verify the possibility of the application for the device as an educational materials. Through this research, show an innovative solution, which contribute to electrical safety and energy conservation, and open the potential possibility on educational and industrial sectors.This kind of research is expected to contributes to enhanced research, and education on electrical safety and energy conservation management.

Experimental Investigation of the Electrostatic Discharge(ESD) Damage in Packaged Semiconductor Devices (패키지 반도체소자의 ESD 손상에 대한 실험적 연구)

  • Kim, Sang-Ryull;Kim, Doo-Hyun;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.94-100
    • /
    • 2002
  • As the use of automatic handling equipment for sensitive semiconductor devices is rapidly increased, manufacturers of electronic components and equipments need to be more alert to the problem of electrostatic discharges(ESD). In order to analyze damage characteristics of semiconductor device damaged by ESD, this study adopts a new charged-device model(CDM), field-induced charged model(FCDM) simulator that is suitable for rapid, routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. High voltage applied to the device under test is raised by the field of non-contacting electrodes in the FCDM simulator, which avoids premature device stressing and permits a faster test cycle. Discharge current and time are measured and calculated. The characteristics of electrostatic attenuation of domestic semiconductor devices are investigated to evaluate the ESD phenomena in the semiconductors. Also, the field charging mechanism, the device thresholds and failure modes are investigated and analyzed. The damaged devices obtained in the simulator are analyzed and evaluated by SEM. The results obtained in this paper can be used to prevent semiconductor devices form ESD hazards and be a foundation of research area and industry relevant to ESD phenomena.

Development of a Screening Method and Device for the Detection of Escherichia coli from Agri-Food Production Environments and Fresh Produce

  • Yun, Bohyun;An, Hyun-Mi;Shim, Won-Bo;Kim, Won-Il;Hung, Nguyen Bao;Han, Sanghyun;Kim, Hyun-Ju;Lee, Seungdon;Kim, Se-Ri
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.12
    • /
    • pp.2141-2150
    • /
    • 2017
  • This study was conducted to develop a screening method using Colilert-18 and a device for the detection of E. coli from agri-food production environments and fresh vegetables. The specificity and sensitivity of Colilert-18 by temperature ($37^{\circ}C$ and $44^{\circ}C$) were evaluated with 38 E. coli and 78 non-E. coli strains. The false-positive rate was 3.8% (3/78) and 0% (0/78) at $37^{\circ}C$ and $44^{\circ}C$, respectively. The detection limit of E. coli at $37^{\circ}C$ at <1.0 log CFU/250 ml was lower than that at $44^{\circ}C$. The efficiency of the developed device, which comprised an incubator equipped with a UV lamp to detect E. coli in the field, was evaluated by measuring the temperature and UV lamp brightness. The difference between the set temperature and actual temperature of the developed device was about $1.0^{\circ}C$. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, there were no differences in detection rates of E. coli compared with the Korean Food Code method. For sanitary disposal of culture samples after experiments, the sterilization effect of sodium dichloroisocyanurate (NaDCC) tablets was assessed for use as a substitute for an autoclave. The addition of one tablet of NaDCC per 50 ml was sufficient to kill E. coli cultured in Colilert-18. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.

Simulation Study on the Safety of a Fastening Device of Agricultural By-product Collector (동역학 시뮬레이션을 통한 농업부산물 수집기 체결장치의 안전성 분석)

  • Jeong-Hun Kim;Seok-Joon Hwang;Ju-Seok Nam
    • Journal of Drive and Control
    • /
    • v.20 no.3
    • /
    • pp.42-49
    • /
    • 2023
  • In this study, the safety of fastening device for the agricultural by-product collector was evaluated according to the driving ground conditions by deriving the stress, static safety factor, and fatigue life using dynamic simulation. A 3D modeling of agricultural by-product collector was carried out, and simulation model was developed by applying the material properties. As a result of dynamic simulation, the magnitude of the maximum stress generated in the fastening device was the highest when driving on the flat off-road, followed by sloped pave-road and flat pave-road. Static safety factor and fatigue life were the highest when driving on the flat pave-road, followed by sloped pave-road and flat off-road. The safety of fastening device was confirmed that static safety factor was more than 1.0 and service life exceeded 9 years in all driving ground conditions.

Development of the Safety Steering System of Motor Vehicles Transmission (차량용 변속기의 조향안전화 제어장치의 개발)

  • 송창섭
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.2
    • /
    • pp.12-17
    • /
    • 1995
  • The operation of heavy tracked vehicle has the problems in the steering that made by misoperations. The protection device is applied to the vehicles. But that device is applied to the vehicles. But that device has the engine stop and over load condition problems. the steering safety system is developed on the basis of clutch slip that proved the durability in the dynamo test and field test. The steering safety system caused the performance improvement of vehicles when steering.

  • PDF

Safety of Industrial Overhead Doors : A Review of Maintenance and Parallel Safety Devices (산업용 오버헤드 도어의 사고 예방 : 유지관리 및 병렬구조 안전장치를 중심으로)

  • Bok Ki Kim;Jaewook Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.33-40
    • /
    • 2024
  • This study analyzes the impact of regular preventive maintenance (PM) on reducing the failure rate and occurrence of falling accidents of industrial overhead doors. A reliable safety device model with an additional safety device, which is installed to replace a defective one, is proposed. The research methodology involves collecting breakdown and falling accident records, comparing and analyzing data before and after regular PM implementation, and experimenting with two types of retrofittable safety devices. Key findings are as follows. 1. Regular PM implementation significantly reduces the failure rate of old overhead doors. 2. A parallel structured model with two alternative safety devices can minimize falling accident risks. The study's contributions include the following. 1. The positive impact of PM on extending overhead door lifespan is quantified. 2. A general safety device model that can be retrofitted and used as replacement with a fail-safe function is proposed.

A Study on Safety Management for Senior-Friendly Medical Devices (고령친화 의료기기의 안전관리방안 연구)

  • Lim, Kyeongmin;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.256-267
    • /
    • 2018
  • The number of items and the market size of the senior-friendly medical devices are rapidly increasing, and it is necessary to come up with a safety management plan for senior-friendly medical devices. We searched and analyzed the definition and policy of senior-friendly medical device, and classified medical device items of the Ministry of Food and Drug Safety, calculated market sizes and manufacturing export import results by classification, and investigated the current state of senior-friendly industry and the fields of its culture. In order to prepare a safety management plan, we reduce the number of items that need to be managed intensively by extracting 69 items for administration, that are substantially harmful to the elderly. As specific safety management plans of items for administration, we propose plans for introductions of readability-enhanced labeling, QR codes for cautions and manuals, universal design mandatory, UDI code system with considering a balanced viewpoint of the industry development.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Shock and Vibration Reduction of the Opto-Electronic Protective Device for the Press Machine (프레스 광전자식 방호장치의 충격진동 저감)

  • Choi, Seung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.13-16
    • /
    • 2011
  • The vibration and shock of the opto-electronic protective device was induced mechanical failure or fail to work correctly. In order to identify the exciting frequency components of vibration and shock, vibration signals are measured and analyzed from the mechanical power press. In addition, the modal test for the opto-electronic protective device was performed to investigate the dynamic characteristics. Some FEM simulations were carried out and then anti vibration mount was made for opto-electronic protective device. Based on the results of simulations, some kind of rubber mounts were tested to demonstrate the reduction of vibration and shock. It was verified by the test that a considerable amount of vibration and shock were reduced.