• Title/Summary/Keyword: Safety Data

Search Result 11,007, Processing Time 0.044 seconds

Present Use of Trails and Influential Factors on Trail Selection -in Mudeung-san Provincial Park- (무등산(無等山) 도립공원(道立公園)의 등산로(登山路) 이용현황(利用現況)과 등산로(登山路) 선정요인(選定要因))

  • Kim, Sang-Oh;Oh, Kwang-In
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.131-144
    • /
    • 1998
  • Understanding of the reasons why users in recreation settings select particular trails may provide useful information for effective recreation resources management. This study investigated the present use of the major trails in Mudeung-san Provincial Park and the major influential factors on trail selection. This study was conducted in Mudeung-san Provincial Park stretching over Hwasun-gun and Damyang-gun of Chonnam Province and Kwang-ju city during August in 1996. Data were collected through on-site survey and mail-back questionnaire. 519(44.2%) out of 1173 survey samples were used for analysis. Reasons for selecting a particular trail were classified into 8 major factors. In overall, the order of the importance degree of the factors was 1) aesthetics of landscape, 2) safety(from physical and crime), 3) conditions for health, 4) quietness, 5) familiarity, 6) on the way to the destination, 7) convenience/social, 8) others' intention. There were differences in the degree of importance of each factor depending on trails, users' characteristics(eg., gender, age, group size, visit experience, etc.) and users' behavioral patterns. Recreation motivations were classified into 5 major factors. The order of the importance degree of the factors was 1) contacting with nature, 2) self-training, 3) solitude, 4) social interaction, 5) appreciating cultural properties. Regardless of trails, 'contacting with nature' was the most important factor, and the degree of importance in the other 4 motivational factors showed only a little differences in order according to the trails. There were correlations between major factors for trail selection and recreation motivations. The results of this study may provide foundational information for establishing effective management strategies through better understanding of the present use of trails and influential factors on trail selection. It can be used for reducing the present social and ecological problems caused by use concentration on certain trails and providing users with better quality of diverse recreational experiences. This study discussed the findings, and suggested some management strategies based on these information.

  • PDF

A Study on User Behavior and Satisfaction with Neighborhood Parks within Walking Distance with Consideration for Interior and Exterior Environments - Focusing on the Case Study Hwarang and Gwanum Park, Daegu - (도보권 근린공원의 내·외부 환경을 고려한 이용행태 및 만족도에 관한 연구 - 대구광역시 화랑공원과 관음공원을 대상으로 -)

  • Jung, Sung-Gwan;Lee, Seul-Gi;Kang, Dong-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.110-123
    • /
    • 2014
  • Recently, having neighborhood parks within walking distance has grown in importance. The purpose of this study is to analyze the effect of user satisfaction with neighborhood parks within walking distance considering interior and exterior environments. To do so, a field survey and GIS were conducted to construct data which were then compared with result of the analysed environment. Finally, amultiple regression analysis was conducted to confirm impact on user satisfaction of environment. By summarizing the study results, it was found that users of Hwarang Park exhibited a high level of satisfaction with 'park facilities' and 'safety of park use'. In the case of Gwanum Park, users exhibited a high level of satisfaction with 'green space' and 'amount of shade'. On the contrary, two park users exhibited low levels of satisfaction with 'facilities for children' and 'various attractions' within the parks. The pedestrian environment of Hwarang Park was rated higher than Gwanum Park within the park service area. User satisfaction was also rated higher than for Gwanum Park. However, two park users exhibited low levels of satisfaction with 'various attractions' within the pedestrian environment. From the result regression analysis of the total satisfaction factors, 'environment of access route', 'park facilities' and 'space for walking' positively influenced park use satisfaction. It was found that improvement of the pedestrian environment would be more effective than the improvement of the internal environment on Hwarang Park. This study investigated correlation with the access road environment as well as the interior environment of the parks. The results of this research will be used to improve accessibility and availability for neighborhood parks within walking distance.

The effects GeongshinhaeGihwan 1(GGT1) has on the hGHTg (human growth hormone transgenic) obese male rats' blood-antiobestic index (형질전환 비만모델 수컷 hGHTg rats에서 경신해지환(輕身解脂丸)이 혈중 항비만지표에 미치는 영향)

  • Jung, Yang-Sam;Tsung, Pei-Chin;Choi, Seung-Bae;Kim, Gyeong -Cheol;Shin, Soon-Shik
    • Herbal Formula Science
    • /
    • v.13 no.2
    • /
    • pp.1-16
    • /
    • 2005
  • Objectives: To find out the effects GGTl, an antiobestic drug widely used in clinics, has on the blood-antiobestic index and the toxicity index using the data from the hGHTg obese male rats. We looked closely into both of the two indices because GGTl antiobestic effect can happen not only by pharmacological action, but also by its toxicity. Also, we verified the difference in effect between GGTl and reductil (sibutramine), which has been approved by the FDA of the United States. Methods: After performing the experiments for 8 weeks on the hGHTg obese male rats divided into three groups: the control group, the GGTl group, and the reductil (RD) group, we anesthetized the rats with Diethyl ether and took a 3ml blood sample from the heart. Then, after coagulating the blood in room temperature by using the plasma separator, we centrifuged it for 25 minutes in 3,000rpm using the high-speed refrigerated centrifuge. We kept the separated plasma in a deep freezer at $-80^{\circ}C$, and repeatedly measured the antiobestic index and the toxicity index twice using the hematology biochemistry analyzer. Also, in order to judge the indirect toxicity index, we separated liver from kidney and observed them. Results: When we looked at the results of the analysis of covariance on the measuring elements related to the antiobestic index (TC, HDL, LDL, TG, and GLU), there was no significant difference among the groups in all measuring elements. Also, the results of the analysis of covariance on the two roups (RD group and GGTl group) showed that the p-values had no significant difference under the level of significance 0.05. When we looked at the result of the analysis of covariance on the measuring elements related to the toxicity index (GOT, GPT, GGT, CREA, UA, ALB, and TP), we could see that the p-values in GPT, ALB, and TP have a significant difference among the groups. Also, the results of the analysis of covariance about the measuring elements related to the toxicity index on both groups, RD group and GGTl group, showed no significant difference in the p-values of all of the measuring elements in the two groups, RD and GGTl group. Conclusions: In conclusion, through this experiment, the safety of GGTl has been approved, and although the verification on its medical effect has not been clearly approved, when we consider the fact that it belongs to the same group as reductil, an antiobestic drug approved by the FDA of the United States, we could indirectly verify that GGTl has an antiobestic effect. We believe that when doing a sample design for a future experiment, it needs to be performed on a greater sample size based on the power analysis that needs to be performed primarily in experiments, and a more accurate verification is needed through more systematic experiment plans.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Toxicity Test of Carbosulfan and Phenthoate on Killifish (Carbosulfan과 Phenthoate의 송사리(Oryzias latipes, Medaka)에 대한 독성시험)

  • Bae, Chul-Han;Lee, Jeong-Seok;Cho, Kyung-Won;Park, Hyun-Ju;Cho, Dong-Hun;Shin, Kwan-Seop;Jung, Chang-Kook;Park, Yeon-Ki
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.4
    • /
    • pp.309-318
    • /
    • 2004
  • Acute toxicity test and chronic toxicity test were conducted with killifish (Oryzias latipes, Medaka) to evaluate toxicity effect of pesticides. Acute toxicity test was investigated mortality in 48 hours and 96 hours after treatment, chronic toxicity test was examined with the early life stage of 30 days after hatching be started embryos of Medaka. The test substances were two pesticides, Carbosulfan and Phenthoate, applied to the paddy rice plant and well-known to the high fish toxicity. As the result of acute toxicity test, median concentration $(LC_{50})$ at 96 hours in Medata was Carbosulfan 0.102 mg/L and Phenthoate 0.167 mg/L, and Fish early life stage toxicity test was conducted on basis of the result of acute toxicity test and concluded from the investigation of hatching success, period of hatching, survival post hatching, length and weight of surviving fishes and abnormal fish. The results of early life stage toxicity test were represented by no observed effect concentration (NOEC), lowest observed effect concentration (LOEC) and maximum acceptable toxicant concentration (MATC). NOEC was Carbosulfan 0.0067ppm and Phenthoate 0.011ppm, LOEC of PCP-Na, Carbosulfan and Phenthoate were 0.017ppm and 0.029ppm, MATC of Carbosulfan and Phenthoate were 0.011ppm and 0.018ppm. These studies will be expected to supply more varied chronic toxicity effects at lower concentration than acute toxicity test. Therefore, evaluation data will be more realistic and the risk assessment of pesticide will be leveled up.

A Study on Total Mercury and Methylmercury in Commercial Tuna, Billfish, and Deep-sea Fish in Seoul Metropolitan City (서울시 유통 다랑어류, 새치류 및 심해성 어류의 총수은 및 메틸수은 축적에 대한 고찰)

  • Kim, Jin-Ah;Yuk, Dong-Hyun;Park, Young-Ae;Choi, Hee-Jin;Kim, Youn-Cheon;Kim, Moo-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.376-381
    • /
    • 2013
  • In this study, we monitored total mercury and methylmercury concentrations in tuna, billfish, and deep-sea fish distributed in Seoul city. With the acquired data, we carried out statistical analysis and an exposure assessment for intake. The mean concentrations (mg/kg) of total mercury and methylmercury were $0.32{\pm}0.31/0.20{\pm}0.20$ for tuna, $0.43{\pm}0.48/0.20{\pm}0.17$ for patagonian toothfish, $0.99{\pm}0.72/0.51{\pm}0.40$ for billfish and $1.20{\pm}0.70/0.95{\pm}0.51$ for sharks, respectively. We found that sharks, billfish, patagonian toothfish, and tuna were more contaminated with total mercury and methylmercury, in sequence, and that 66% of the total mercury concentration consisted of methylmercury, on average. Although the estimated weekly intakes of methylmercury from commercial deep-sea fish were lower than the weekly intakes recommended by the Joint FAO/WHO Expert Committee on Food Additives (JECFA), we identified that the total mercury and methylmercury concentrations in tuna, billfish, and deep-sea fish continued to increase with the passage of time. Therefore, we confirmed the necessity of continuous monitoring and comprehensive analysis for general safety.

Geochemical Characteristics of the Gyeongju LILW Repository II. Rock and Mineral (중.저준위 방사성폐기물 처분부지의 지구화학 특성 II. 암석 및 광물)

  • Kim, Geon-Young;Koh, Yong-Kwon;Choi, Byoung-Young;Shin, Seon-Ho;Kim, Doo-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.307-327
    • /
    • 2008
  • Geochemical study on the rocks and minerals of the Gyeongju low and intermediate level waste repository was carried out in order to provide geochemical data for the safety assessment and geochemical modeling. Polarized microscopy, X-ray diffraction method, chemical analysis for the major and trace elements, scanning electron microscopy(SEM), and stable isotope analysis were applied. Fracture zones are locally developed with various degrees of alteration in the study area. The study area is mainly composed of granodiorite and diorite and their relation is gradational in the field. However, they could be easily distinguished by their chemical property. The granodiorite showed higher $SiO_2$ content and lower MgO and $Fe_2O_3$ contents than the diorite. Variation trends of the major elements of the granodiorite and diorite were plotted on the same line according to the increase of $SiO_2$ content suggesting that they were differentiated from the same magma. Spatial distribution of the various elements showed that the diorite region had lower $SiO_2,\;Al_2O_3,\;Na_2O\;and\;K_2O$ contents, and higher CaO, $Fe_2O_3$ contents than the granodiorite region. Especially, because the differences in the CaO and $Na_2O$ distribution were most distinct and their trends were reciprocal, the chemical variation of the plagioclase of the granitic rocks was the main parameter of the chemical variation of the host rocks in the study area. Identified fracture-filling minerals from the drill core were montmorillonite, zeolite minerals, chlorite, illite, calcite and pyrite. Especially pyrite and laumontite, which are known as indicating minerals of hydrothermal alteration, were widely distributed in the study area indicating that the study area was affected by mineralization and/or hydrothermal alteration. Sulfur isotope analysis for the pyrite and oxygen-hydrogen stable isotope analysis for the clay minerals indicated that they were originated from the magma. Therefore, it is considered that the fracture-filling minerals from the study area were affected by the hydrothermal solution as well as the simply water-rock interaction.

  • PDF

Monitoring of Aflatoxins in Medicinal Herbs (유통 생약재의 아플라톡신 모니터링)

  • Kim, Yong-Hoon;Kang, Han-Saem;Oh, Sun-Woo;Lee, Hwa-Jung;Kim, Mi-Gyeong;Chung, So-Young;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Lee, Ji-Won;Kim, Young-Seon;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • This study was conducted to monitor aflatoxins in various medicinal herbs, providing available data for the safety of those products. To monitor aflatoxins in medicinal herbs, a total of 400 samples of 40 different herbs were collected in commercial retailers in Seoul, Daejeon, Gwangju, Daegu, and Busan from March to August, 2008. The samples that passed the sensory evaluation were tested for aflatoxins. Aflatoxins in samples were analyzed by HPLC-florescence coupled with photochemical enhancement. Samples were extracted with 70% methanol and then diluted to the appropriate concentration. A refining process was performed using an immunoaffinity column. The analytical method used in this study was validated. The $R^2$ value for aflatoxin $B_1$ was 0.99946, and the detection range was from 0.25 to 10.0 ng/mL. The accuracy of the analysis was ranged from 83.2% to 101.8%. The relative standard deviation (RSD) in the aflatoxin $B_1$ analysis was 3.4%, demonstrating the precision of this method. In addition, the detection limit and quantitative analysis limit of aflatoxin $B_1$ was $0.53\;{\mu}g/kg$ and $1.76\;{\mu}g/kg$, respectively. These results indicated that the analytical method used in this study was appropriate. The results of HPLC showed that 1% (4 samples) of the samples may contain aflatoxins. The concentration of quantified aflatoxin was $2.3\;{\mu}g/kg$ for both Quisqualis fructus and Remotiflori radix samples. The other samples were below the limit of quantification. Moreover, the concentration of aflatoxin $B_1$ which is made by specific fungi were below the level of regulation. Only 20% of aflatoxin $B_1$ were transferred to hot water. Therefore, the levels of aflatoxins in medicinal herbs were considered to be safe especially considering the aflatoxin transfer ratio.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF