Design of a DC Motor Controller for FA (FA용 직류전동기 제어기 설계)

  • 오진석
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.49-57
    • /
    • 1994
  • In this paper, a speed controller using a controller is implemented and applied to a DC motor for FA ( Factory Automation ). The objective of this paper treats the analytical and experimental studies on the improvement of control circuit and control method using a SCR-LEONARD circuit for the speed control of DC motor. This system is concerned with stabilization of single input or single output systems, so the plant (SCR-LEONARD+DC motor) is simplified to the first order system. The parameters for the PID controller are obtained by the transient-response tunning method, and this control scheme has a backward-shift operator. The control algorithms (Chopper+transient response tunning) is used to check the performance of PID Controller through Computer simulations and experiments. The good experiment results show that the direct control of the DC motor applied to industrial field such oi factory automation.

  • PDF

Feasibility study for the self powered wireless emergency call button using electromagnetic energy harvesting mechanism (전자기유도방식의 에너지 하베스팅을 이용한 자가발전 무선 비상호출기 구현 연구)

  • Kim, Il-Jung;Choi, Yeon-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.111-119
    • /
    • 2014
  • This paper describes the design and implementation of a electromagnetic energy harvesting mechanism and electronic circuit for autonomous emergency call system. This analysis results show the power output of the proposed harvesting mechanism and circuit up to max power output 5V and it can hold up to 65 msec of the power generation and 10msec of the RF transmission. Based on the these testing results, the implementation of autonomous emergency call device without battery power or any external power source is feasible.

A Study on Electric Power Propulsion System for Small Ship Outboard (소형선박 선외기용 전기동력 시스템 연구)

  • Park, Joo-Sik;Won, Jun-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.309-316
    • /
    • 2017
  • Recently, the outboard engine system of internal combustion engine is widely used in the field of small ship propulsion. However, the internal combustion engine has serious problems of energy depletion and environmental problems, so electric propulsion methods are being studied. In this paper, we have developed important motors and controllers of electric propulsion system for small marine outboard motors. The motor design was performed through the motor characteristics analysis method, and the 30Kw system was developed through the BEMF processing circuit and the power conversion circuit by the embedded microprocessor. This study was carried out through government supported projects and achieved quantitative targets through accredited institutions.

A Voltage Drops Computation Program on Multi-Distributed Random Loads (다중 분산부하 전압강하산정 프로그램)

  • Kang, Cha-Nyeong;Kwon, Sae-Hyuk;Cho, Sung-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.64-70
    • /
    • 2007
  • A voltage drop in the electrical circuit must be unavoidable. The voltage drop in the electrical circuit means a loss of heat. The heat lost would change the characteristics of the insulator and thus, the insulating performance would be towered resulting in electric leakage, electric shock, power failure, fire and other accidents. Hence, an optimized design against the voltage drop in the electrical circuit must be an important factor determining safety and economy of electrical facilities. This study analyzed the effects of voltage drop on the electrical circuit for such low-voltage electrical facilities requiring the public safety foremost and subject to multi-distributed random loads as street lamps, buildings and subway stations, and thereupon, developed an optimized voltage drop computation program to enhance safety and economy of those electrical facilities.

Design of a High-Voltage Piezoelectric Converter for Airbag Ignition Modules

  • Xiao, Hongbing;Du, Yu;Bai, Chunyu;Guo, Zerong;Yen, Kang K.
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.183-193
    • /
    • 2014
  • Due to the requirements for high reliability and accuracy, safety issues for airbag ignition systems need to be studied. In this paper, a high-voltage piezoelectric converter is designed to improve these requirements in airbag ignition systems. The proposed converter includes an inverter drive circuit, a Rosen piezoelectric transformer (PZT), an output circuit and a feedback control circuit. The key components of the high-voltage piezoelectric transformer are analyzed in detail. In addition, the proposed converter system is simulated and implemented for testing. The experimental results show that when the power supply is turned on, the charging time is less than 800ms. Furthermore, the output voltage of this converter can be kept between 2.9kV and 3.1kV, under high-efficiency constant current charging mode and zero-voltage switching conditions.

Safely Evaluation on Common Grounding System for Electric Railway (전기철도의 공용접지 시스템에 대한 안정성 평가에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.298-306
    • /
    • 2002
  • We performed an safety evaluation on constructing of a common grounding system for electrical railway in view of its efficacy and technical fit. In order to compare the conventional grounding method, which has been individually conducted, with the common grounding with all ground wires connected in common to the counterpoise buried below the surface of the earth in parallel with rail, we set up scenarios with several cases of fault and load conditions in Chungbuk railway sections with the common grounding system. Based on models for railway conductors including the grounded system, line Parameters of railway power system are computed. The circuit model for power system with up and down lines, auto-transformers and railway substations is used to compute impedances of counterpoise and substation ground net. For each scenario with faults and operation conditions of railway, the induced potentials on signal and communication lines are also computed. It is shown that the common grounding for Chungbuk railway is superior experimentally to the conventional method in three respects: (1) the lower rail potentials during operation of railway in line, (2) the lower rail potentials for short-circuit faults between catenary and rail, and (3) the lower stress voltages on signal and communication lines for short-circuit or ground faults. The analysis results confirm that the grounding system for electric railway is required to be built by the common grounding and be evaluated on its safety in design.

A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line (350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구)

  • Lee, Hack-Pyo;Seo, Ki-Bum;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

A Study on Heat-Flux Evaluation for Cable Fire Including Diagnostic Methodology for Degradation in Nuclear Power Plants (원전 케이블 화재 열속평가 및 열화 진단방법에 관한 연구)

  • Lim, Hyuk-Soon;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.20-25
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a multi-core cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the characteristic of cable fire is investigated and the heat-flux evaluation for cable fire is studied. Moreover, a diagnostic methodology for degraded cable in nuclear power plants is presented.

Electric Therapy System Based on Discontinuous Conduction Mode Boost Circuit

  • Chen, Wenhui;Lee, Hyesoo;Jung, Heokyung
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.4
    • /
    • pp.245-253
    • /
    • 2020
  • The human body and nervous system transmit information through electric charges. After the electric charge transmits information to the brain, we can feel pain, numbness, comfort, and other feelings. Electric therapy is currently used widely in clinical practice because the field of examination is more representative of electrocardiogram, and in the field of treatment is more representative of electrotherapy. In this study, we design a system for neurophysiological therapy and conduct parameter calculation and model selection for the components of the system. The system is based on a discontinuous conduction mode (DCM) boost circuit, and controlled and regulated by a single-chip microcomputer. The system does not only have a low cost but also fully considers the safety of use, convenience of the human-computer interface, adjustment sensitivity, and waveform diversity in the design. In future, it will have strong implications in the field of electrotherapy.

The Novel Control Circuit Design and Implementation for an AIS Power Amplifier Module (AIS용 전력 증폭기 모듈의 새로운 출력 제어 회로 설계 및 제작)

  • 한재룡;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.251-257
    • /
    • 2004
  • AIS(Automatic Identification System), was suggested for the navigational data communication between ships and between ships and shore stations for the better safety of navigation, and it requires two different the transmitting output power level depending on its operating mode. According to ITU's recommendation, these levels should reach within 20 % of its final value in 1 ms. In this paper, an adequate feedback control circuit for power amplifier module is designed and implemented.