• 제목/요약/키워드: Safe End

검색결과 358건 처리시간 0.034초

항공교통관제사와 조종사 인적오류의 연계성 (Association of Human Error on Air Traffic Controller and Pilot)

  • 문우춘;최연철;양한모
    • 한국항공운항학회지
    • /
    • 제16권4호
    • /
    • pp.35-40
    • /
    • 2008
  • There are many studies indicate that human is one of the major contributing factors to the aviation accident. To this end, the Human Factor of pilots and in flight operations has been a popular subject to be studied, however, not of the air traffic controllers. Recently, some States have started studying Human Errors in Air Traffic Control field, removal of the potential errors in advance and prevention of the similar errors. This study analyzed Human Errors in air traffic control in terms of LOSA of airlines, which has been actively studied. This study will contribute to safe Flight Operation and Air Traffic Control.

  • PDF

3상 농형 유도전동기 회전자 바의 고장진단에 관한 연구 (A Study on The Diagnosis of Broken Rotor Bars in Three Phase Squirrel-Case Induction Motor)

  • 김근웅;권중록;이갑재;김완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.635-637
    • /
    • 2001
  • The faults of the squirrel cage induction motor is grew increasingly complex as the faults resulting in the shorting of a stator winding and the broken rotor bar or cracked rotor end ring, bearing faults, and so on. The users of electrical machines initially relied on simple protections such as over-current, over-voltage, earth-fault, etc. to ensure safe and reliable operation. but this method cause heavy financial losses and the threat of safety therefore it has now become very important to diagnose faults at there very inception. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF

스마트 무인기 4자유도 지상시험치구 구조진동해석 (Structural Vibration Analysis of Smart UAV 4-Degree of Freedom Ground Test System)

  • 박강균;최현철;김동만;김동현;안오성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.593-598
    • /
    • 2009
  • In this study we present results for the design of ground test system for 4 degree of freedom(DOF) control test is one of the smart UAV ground test. This system is equipped with real smart UAV and Z direction DOF and 3 direction rotation DOF, Ensuring safe operation of the Smart UAV is a top priority. To this end, it is required to do structure analysis and test verification to confirm the design margin and safety. Based on the analysis, the ground test system has been redesigned to meet the structural conditions.

  • PDF

Body Plethysmograph 방법과 폐쇄식회로법으로 측정한 기능적잔기량의 비교 (A Comparison of Thoracic Gas Volume measured by Body Plethysmographic Method and Functional Residual Capacity measured by Closed Circuit Method)

  • 정치경
    • Journal of Preventive Medicine and Public Health
    • /
    • 제3권1호
    • /
    • pp.17-22
    • /
    • 1970
  • By using Siregnost FD 91 body plethysmograph, we measured thoracic gas volume (TGVe) at end of expiration in 19 healthy subjects aged 20-43 years in order to compare with functional residual capacity (FRC) measured by closed circuit method. The results obtained were as follows 1. Mean values of TGVe and FRC were $3.395{\pm}0.5851{\ell},\;and\;3.393{\pm}0.618{\ell}$, respectively. 2. A advantage of the body phethysmographic method for measuring thoracic gas volume was that it were rapid, safe, and easy to perform, requires no gas sample for chemical analysis, and measured TGVe several times.

  • PDF

스테인리스 차체의 시험에 의한 구조강도 평가 (An evaluation of structural strength by testing the carbody of stainless steel material)

  • 윤성철;전창성;김원경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1523-1526
    • /
    • 2007
  • This study introduces the testing results of the carbody. The load test was performed to evaluate the structural characteristic and stability of the stainless carbody. The carbody is made of stainless steel. The body structure consisted of side frame, under frame, roof frame, and end frame. Of these components, the side frame and under frame were the most important components considering the vehicle and passenger loads. Loading test were performed under the condition based on "Performance Test Standard for Electrical Multiple Unit". The test results showed that the body structure is safe and stable under the condition of designed load.

  • PDF

General Pharmacology of PEG-Hemoglobin SB1

  • Kim, Eun-Joo;Lee, Rae-Kyong;Bak, Ji-Yeong;Choi, Gyu-Kap
    • Biomolecules & Therapeutics
    • /
    • 제7권2호
    • /
    • pp.170-177
    • /
    • 1999
  • PEG-hemoglobin SB1 (SB1), which is a hemoglobin-based oxygen carrier, is intended to use as a safe blood substitute against brain ischemia and stroke. The general pharmacological profiles of SB1 were studied. The doses given were 0, 5, 10, 20 ml/kg and drugs were administered intravenously. The animals used for this study were mouse, rat and guinea pig. SB1 showed no effects on general behavior, motor coordination, spontaneous locomotor activity, hexobarbital sleeping time, anticonvulsant activity, analgesic activity, blood pressure and heart rate, left ventricular peak systolic pressure, left ventricular end diastolic pressure, left ventricular developing pressure, double product, heart rate, coronary flow rate, smooth muscle contraction using guinea pig ileum, gastrointestinal transport, gastric secretion, urinary volume and electrolyte excretion at all doses tested except the decrease of body temperature. These findings demonstrated that SB1 possesses no general pharmacological effects at all doses tested.

  • PDF

Dual-Chamber Technology: Safe and Convenient Drug Delivery for Lyophilized Biologics

  • Moore, John
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제1권1호
    • /
    • pp.28-30
    • /
    • 2015
  • Biologics present a challenge to both the manufacturer and end user. They must usually be formulated as parenterals. However, they are often unstable in liquid form, due to their complex structure and composition. In that case, they must be manufactured using highly specialized processes, such as lyophilization (freeze-drying). Lyophilization nearly eliminates stability issues. Reducing a compound's sensitivity to temperature prolongs its shelf life. However, reconstitution can be cumbersome, involving multiple steps that increase the potential for error. Dual-chamber technology provides an effective alternative, combining a lyophilized drug and diluent in a closed system and enabling reconstitution in a few simple steps.

탄소 고형물에 의한 터빈의 이상 진동 (Abnormal vibration of steam turbine due to carbon deposit at journal bearing in 500MW thermal power plant)

  • 구재량;황재현;김연환;이우광
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.234-238
    • /
    • 2002
  • Lubricating oil supply system is an essential instrument for safe turbine operation. A lubricating condition may cause the abnormal vibration of turbine. In this paper we have discussed the abnormal vibration of turbine due to lubricating oil. Dusts of the air usually attach to end of the oil deflector and contact particles of the bearing oil. Dusts which were contacted particles of the bearing oil were changed into carbon deposit because of high temperature. therefore, carbon deposits occur abnormal vibration of the turbine when they contact a rotor. So, we have solved this problems through the various maintenance.

  • PDF

원자력 배관 이종금속 용접부 웅력부식균열의 역학적 평가 (Mechanics Evaluations of Stress Corrosion Cracking for Dissimilar Welds in Nuclear Piping System)

  • 박준수;나복균;김인용
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 추계학술발표대회 개요집
    • /
    • pp.38-40
    • /
    • 2005
  • Fracture mechanics evaluation of stress corrosion cracking (SCC) in the dissimilar metal weld (DMW) for the nuclear piping system is performed; simulating the transition joint of the ferritic nozzle to austenitic safe-end fabricated with the Inconel Alloy A82/182 buttering and welds. Residual stresses in the DMW are computed by the finite element (FE) analyses Then, to investigate the SCC in the weld root under the combined residual and system operation stresses, the fracture mechanics parameters for a semi-elliptical surface crack are evaluated using the finite element alternating method (FEAM). As a result, it is found that the effect of weld residual stresses on the crack-driving forces is dominant, as high as three times or more than the operation stresses.

  • PDF

세균성 동맥내막염을 동반한 개방성 동맥관의 치험예 (Surgery of the Infected Patent Ductus Arteriosus with Teflon Wrapping)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제5권1호
    • /
    • pp.25-28
    • /
    • 1972
  • Patent ductus arteriosus is one of the most common congenital heart diseases, which treated operatively has excellent results. Treatment by surgical means is common and invariably successful. However,infected PDA cases present problems and surgeons operating must face the possibility of adhesions,aneurysmal dilatation and friabiilty of tissue with tearing of the pulmonary arterial end, especially, which causes a fatal hemorrhagic ccmplication. In the earlier days of cardiac surgery, many surgeons deferred operative treatment infected PDA because of frequent complications, high postoperative morbidity and mortality. This continued until Touroff et al. successfully divided the infected PDA in 1940. In 1944, Harper et aI. have used Cellophane for the wrapping of the infected PDA. This surgical procedure has become a single, simple and safe method for treating infected PDA, since that time. In the Teflon wrapping technique, a cardiothoracic team of Yonsei University Severance Hospital used Teflon felt instead of Cellophane in one case of infected PDA and this method proved intractable to antibiotic treatment for 40 days.

  • PDF