• Title/Summary/Keyword: SV2C

Search Result 141, Processing Time 0.031 seconds

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Effects of ventilation systems and set point temperature of single-span plastic greenhouse on disease incidence, fruit quality and yield of oriental melon (Cucumis melo L.) (참외재배 단동 비닐하우스의 환기방법과 설정온도가 병발병도,과실 수량 및 품질에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Rhee, Han-Cheol;Choi, Gyeong-Lee;Lee, Seong-Chan;Lee, Jung-Sup
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.4
    • /
    • pp.325-333
    • /
    • 2015
  • The ventilation systems composed three types of side vent (roll-up) 'SV', side vent+roof vent 'SV+RV', and side vent+roof fan 'SV+RF' with 7.5 m spacing, with specific set point temperatures for ventilation: SV ($35^{\circ}C$ open / $33^{\circ}C$ close), SV+RV or SV+RH ($35^{\circ}C$ open/$33^{\circ}C$ close for root ventilation and $37^{\circ}C$ open / $35^{\circ}C$ close for side vent). In the treatment of SV+RV, although the average daily maximum temperature inside the greenhouse temporarily increased by $38-40^{\circ}C$, thermal stress by high temperature did not occur and the disease incidence (%) of powdery mildew and downy mildew on the oriental melon were 25 - 75% lower than in the conventional SV treatment. In the SV treatment, the disease incidence (%) of powdery mildew and downy mildew were 1.4 - 7.7% and 4.2 - 15.9% for 'Deabakkul', and 20.3 - 22.8% and 2.8 - 11.3%, for 'Ildeungkkul'. The yield for one month was higher in the treatment of SV+RV than those in other treatments, with values of 2,105 kg/10a for 'Deabakkul' and 2,537 kg/10a for 'Ildeungkkul'. The simultaneous treatment with side vent and roof vent resulted in 16.2% higher yield (18.1% higher marketable yield) than that in the SV treatment for 'Deabakkul'.

Synaptic Vesicle Protein 2 (SV2) Isoforms

  • Bandala, Cindy;Miliar-Garcia, A.;Mejia-Barradas, C.M.;Anaya-Ruiz, M.;Luna-Arias, J.P.;Bazan-Mendez, C.I.;Gomez-Lopez, M.;Juarez-Mendez, S.;Lara-Padilla, E.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5063-5067
    • /
    • 2012
  • New molecular markers of cancer had emerged with novel applications in cancer prevention and therapeutics, including for breast cancer of unknown causes, which has a high impact on the health of women worldwide. The purpose of this research was to detemine protein and mRNA expression of synaptic vesicle 2 (SV2) isoforms A, B and C in breast cancer cell lines. Cultured cell lines MDA-MB-231, SKBR3, T47D were lysed and their protein and mRNA expression analyzed by real-time PCR and western blot technique, respectively. SV2A, B proteins were identified in non-tumor (MCF-10A) and tumor cell lines (MDA-MB-231 and T47D) while SV2C only was found in the T47D cell line. Furthermore, the genomic expression was consistent with protein expression for a such cell line, but in MDA-MB-231 there was no SV2B genomic expression, and the SV2C mRNA and protein were not found in the non tumoral cell line. These findings suggest a possible cellular transdifferentiation to neural character in breast cancer, of possible relevance to cancer development, and point to possible use of SV2 as molecular marker and a vehicle for cancer treatment with botulinum toxin.

Proporties of SV4O-transformed Human Cells (SV40 바이러스로 형질전환된 사람종양세포의 특성)

  • 최경희;홍승환
    • The Korean Journal of Zoology
    • /
    • v.31 no.1
    • /
    • pp.49-55
    • /
    • 1988
  • A few SV4O-transformed human cells such as SV8O are potentially tumorigenic but rejected by athymic hosts. However, one cell line in this group (W118IVA-2) is known to be fully tumorigenic. Two clones were obtained after the injection of W118IVA-2, of which NW1SC1-1 was tumorigenic but NW18C1-2 was not in nude mice. As examined by Southern blot analysis, NW18C1-1 appears to contain more copy number of SV40 sequences than NW18C1-2 does. However, it was unable to demonstrate that this difference elicits the tumorigenicity in NW18C1-1 but not in NW18C1-2. Therefore, the latter clone was tested if it expresses SV40 early genes to produce large T as well as small t antigens using indirect immunofluorescent assay and immunoprecipitation. In addition, mouse NIH3T3 cells were transfected with the cellular DNA of NW1SC1-2 as well as that of NW18C1-1 to examine if the viral genomes in the clones can make the nontransformed cells to acquire malignant growth potential in vivo. The transformed cells expressed large T antigen and became tumorigenic. Thus, the transforming functions of NW1SC1-2 cell appers to be intact. These results clearly suggest that the inability of NW18C1-2 cell to form tumor in nude mice is not because they are inherently nontumorigenic. However, the possibility that the interaction of SV40 with its host differs in these clones can not he ruled out.

  • PDF

An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station (방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석)

  • Han, Jae-Jin;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

The alternative approach of low temperature-long time cooking on bovine semitendinosus meat quality

  • Ismail, Ishamri;Hwang, Young-Hwa;Bakhsh, Allah;Joo, Seon-Tea
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.2
    • /
    • pp.282-289
    • /
    • 2019
  • Objective: This study aimed to elucidate whether innovative sous vide treatment has a significant influence on the beef semitendinosus muscle as compared to common sous vide treatment and traditional cooking. Methods: The innovative sous vide treatments were cooked at $45^{\circ}C$ and $65^{\circ}C$ for 6 h (SV45-65), common sous vide treatment at $45^{\circ}C$ and $65^{\circ}C$ for 3 h (SV45 and SV65) and traditional cooking at $75^{\circ}C$ for 30 min (CON75). Water loss and cooking loss, as well as the physical properties (color and shear force) and chemical properties (protein and collagen solubility) of the treated meat, were investigated. Results: The results obtained indicated that the innovative sous vide with double thermal treatment (SV45-65) and cooked with air presence (CON75) resulted to lower $a^*$ and higher $b^*$ values, respectively. The water loss and cooking loss increased when temperature increased from $45^{\circ}C$ to $65^{\circ}C$, and lower water loss was recorded in SV45 and CON75. These samples presented higher water content and revealed strong correlation to protein solubility. Warner-Bratzler shear force (SF) analysis showed the marked interaction between cooking temperature and time. Sample cooked at a high temperature (CON75) and a long period (SV45-65) showed a significantly lower value of SF than sample SV65 (p<0.05). Interestingly, there was no difference in SF values between SV45-65 and CON75. Conclusion: The innovative sous vide treatment with double thermal effect appears an attractive cooking method as compared to common sous vide and traditional cooking method, as it has a potential for improving tenderness values of cooked beef semitendinosus muscle.

Evaluation on the Radiological Shielding Design of a Hot Cell Facility (핫셀시설의 방사선 안전성 평가)

  • 조일제;국동학;구정회;정원명;유길성;이은표;박성원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • The hot cell facility for research activities related to the lithium reduction of spent fuel, which is designed to permit safe handling of source materials with radioactivity levels up to 1,385 TBq, is planned to be built. To meet this goal, the facility is designed to keep gamma and neutron radiation lower than the recommended dose-rate in normally occupied areas. The calculations peformed with QAD-CGGP and MCNP-4C are used to evaluate the proposed engineering design concepts that would provide acceptable dose-rates during a normal operation in hot cell facility. The maximum effective gamma dose-rates on the surfaces of the facility at operation area and at service area calculated by QAD-CGGP are estimated to be $2.10{\times}10^{-3}, 2.97{\times}10^{-3} and 1.01{\times}10{-1}$ mSv/h, respectively. And those calculated by MCNP-4C are $1.60{\times}10^{-3}, 2.99{\times}10^{-3} and 7.88{\times}10^{-2}$ mSv/h, respectively, The dose-rates contributed by neutrons are one order of magnitude less than that of gamma sources. Therefore, it is confirmed that the radiological design for hot cell facility satisfies the Korean criterion of 0.01 mSv/h for the operation area and 0.15 mSv/h for the service (maintenance) area.

  • PDF

Assessment of Internal Dose by $^3H\;&\;^{14}C$ of Total Diet for Inhabitants near Wolsung Nuclear Power Plants

  • Park, G.;Lin, X.J.;Kim, W.;Kang, H.D.;Doh, S.H.;Kim, D.S.;Kim, C.K.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • To assess the internal dose by $^3H\;&\;^{14}C$ in total diet of inhabitants near Wolsung Nuclear Power Plants, TFWT, OBT and $^{14}C$ concentration in total diet was analyzed for collection region and time. TFWT, OBT and $^{14}C$ concentrations were in the range of 3.19-42.2 Bq/L, 1.00-39.4 Bq/L, and 0.230-0.855 Bq/gC, respectively. The calculated annual effective dose with TFWT, OBT and $^{14}C$ is $6.10{\times}10^{-5}mSv/y,\;3.71{\times}10^{-5}mSv/y\;and\;7.08{\times}10^{-3}mSv/y$, respectively. And then annual internal dose with total diet for inhabitants near Wolsung NPPs is about $7.18{\times}10^{-3}mSv/y$, which is about 0.72% of annual effective dose limit 1 mSv/y.