• Title/Summary/Keyword: SV

Search Result 1,087, Processing Time 0.032 seconds

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION (두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도)

  • Kim Ae-Jj;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

Effect of Viral Enhancers on the Tissue-Specific Expression of Bovine Growth Hormone Gene (소성장호르몬 유전자의 조직 특이성 발현에 미치는 바이러스 engancer의 영향)

  • 박계윤;김수미;노정혜
    • Korean Journal of Microbiology
    • /
    • v.27 no.2
    • /
    • pp.85-91
    • /
    • 1989
  • The effect of SV40 and murine cytomegalovirus (MCMV) enhancers on the general and tissue-specific gene expression was investigated. Recombinant plasmids containing these transcriptional engancers downstream of a structural gene for chloramphenicol acetyl transferase (CAT) were constructed. The transient expression of CAT gene from these plasmids was measured in monkey (CV1PD) and HeLa cells. Both SV40 and MCMV engancers activated the expression of CAT gene by more than 20 and 150 folds, respectively, compared with engancerless plasmids. When the SV40 promoter, upstream of CAT gene, was replaced with 2.2 kbp of promoter regulatory region of bovine growth hormone (bGH) gene, there was no expression of CAT even in the presence of enhancers, reflecting the tissue-specific expression of bGH genes. However, when the bGH regulatory region was shortened to 230 bp, the expression level increased dramatically in the presence of SV40 enhancers. In contrast, the expression from the shortened promoter was only marginally activated by the stronger MCMV enhancer.

  • PDF

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

Effects of Snake Venom Pharmacopuncture on a Mouse model of Cerebral Infarction

  • Choi, Chul-Hoon;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.140-146
    • /
    • 2019
  • Background: This study investigated the effects of Vipera lebetina turanica snake venom (SV) on cerebral infarction induced by middle cerebral artery occlusion in mice. Methods: Following cerebral infarction, SV was injected intravenously or added to BV2 cell culture. Tissue injury was detected using triphenyltetrazolium chloride (TTC) staining, neurological deficit score, NO, ROS, and GSH/GSSG assays, qPCR, Western blot, and cell viability. Results: Cerebral infarction caused by middle cerebral artery occlusion as observed by TTC staining, showed SV inhibited cell death, reducing the number of brain cells injured due to infarction. SV treatment for cerebral infarction showed a significant decrease in abnormal behavior, as determined by the neurological deficit score. The oxidation and inflammation of the cells that had cerebral infarction caused by middle cerebral artery occlusion (NO assay, ROS, GSH/GSSG assay, and qPCR), showed significant protection by SV. Western blot of brain infarction cells showed the expression of iNOS, COX-2, p-IkB-${\alpha}$, P38, p-JNK, p-ERK to be lower in the SV group. In addition, the expression of IkB increased. BV2 cells were viable when treated with SV at $20{\mu}g/mL$ or less. Western blot of BV2 cells, treated with 0.625, 1.5, $2.5{\mu}g/mL$ of SV, showed a significant decrease in the expression of p-IkB-${\alpha}$, p-JNK, iNOS, and COX-2 on BV2 cells induced by LPS. Conclusion: SV showed anti-inflammatory and anti-oxidant effects against cerebral infarction and inflammation.

Antioxidant Activities of Ethanol Extracts from Solidago virga-aurea var. gigantea (울릉미역취 에탄올추출물의 항산화 활성)

  • Ji, Yoon-Sun;Lee, Nam-Sun;Kil, Ki-Jung;Yoo, Ji-Hyun
    • The Korea Journal of Herbology
    • /
    • v.34 no.1
    • /
    • pp.109-116
    • /
    • 2019
  • Objectives : This study aimed to analyze contents of chlorogenic acid among major ingredients and determine the optimal solvent for the antioxidant activity from Solidago virga-aurea var. gigantea(SV) aerial part. Methods : Mature aerial part of extracted SV at the first crop on June 2018 was used. SV was mixed with each at the ethanol concentrate rates of water, 10, 30, 50, 70, and 100% and extracted them for three times for eight hours at $70^{\circ}C$. The contents of chlorogenic acid and seven kinds of antioxidant activities were measured in SV extracts. Results : The highest the contents of chlorogenic acid was from 10% ethanol extracts showed. Total polyphenol and flavonoids of SV extracts were 126.16 mg/g and 105.84 mg/g, respectively. Scavenging activities of DPPH, ABTS, and hydroxyl radical significantly increased in a dose-dependent in SV extracts, while it was almost similar with control at the concentration of $500{\mu}g/mL$. $Fe^{2+}$ chelating activity significantly increase in a dose-dependent in SV extract, it was lower than control. Nitrite scavenging activity increased, dose-dependent in the sequence of pH 1.2> pH 3.0 > pH 6.0 in SV extracts, while it was almost similar with control at the concentration of $500{\mu}g/mL$, pH 1.2, and pH 3.0. Conclusions : Thus, this study found that higher contents of chlorogenic acid and excellent antioxidant activity were contained in 10% ethanol extracts in mature aerial part of SV. It is expected to be used as basic data as natural antioxidant materials.

Establishment and characterization of an immortalized human dermal papilla cell line

  • Shin, Seung-Hyun;Park, Sang-Yoon;Kim, Moon-Kyu;Kim, Jung-Chul;Sung, Young-Kwan
    • BMB Reports
    • /
    • v.44 no.8
    • /
    • pp.512-516
    • /
    • 2011
  • Establishment of immortalized human dermal papilla cells (DPCs) retaining the characteristics of DPCs would be a great help for hair researchers. We recently established a simian virus 40T (SV40T)-transformed human DP cell line (SV40TDPC). However, the cell line senesced around passage 25 and ceased proliferation. In this study, we introduced the human telomerase reverse transcriptase (hTERT) gene into SV40T-DPC and established an immortalized human DP cell line. The cell line, SV40T-hTERT-DPC, did not induce tumors when inoculated into nude mice. SV40T-hTERT-DPC maintained morphology of early passage DPCs, expressed markers of DPCs, and retained responses to Wnt/${\beta}$-catenin and bone morphogenic protein (BMP) signaling pathways known to be required for hair-inducing activity of DPCs. The data strongly suggest that SV40T-hTERT-DPC retains many characteristics of human DPCs in vivo without malignant transformation.

Identification and Functional Characterization of an afsR Homolog Regulatory Gene from Streptomyces venezuelae ATCC 15439

  • Maharjan, Sushila;Oh, Tae-Jin;Lee, Hei-Chan;Sohng, Jae-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.2
    • /
    • pp.121-127
    • /
    • 2009
  • Sequencing analysis of a 5-kb DNA fragment from Streptomyces venezuelae ATCC 15439 revealed the presence of one 3.1-kb open reading frame(ORF), designated as afsR-sv. The deduced product of afsR-sv(1,056 aa) was found to have high homology with the global regulatory protein AfsR. Homology-based analysis showed that aftR-sv represents a transcriptional activator belonging to the Streptomyces antibiotic regulatory protein(SARP) family that includes an N-terminal SARP domain containing a bacterial transcriptional activation domain(BTAD), an NB-ARC domain, and a C-terminal tetratricopeptide repeat domain. Gene expression analysis by reverse transcriptase PCR(RT-PCR) demonstrated the activation of transcription of genes belonging to pikromycin production, when aftR-sv was overexpressed in S. venezuelae. Heterologous expression of the aftR-sv in different Streptomyces strains resulted in increased production of the respective antibiotics, suggesting that afsR-sv is a positive regulator of antibiotics biosynthesis.

Radiation Exposure from Nuclear Power Plants in Korea: 2011-2015

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.222-228
    • /
    • 2017
  • Background: On June 18, 2017, Korea's first commercial nuclear reactor, the Kori Nuclear Power Plant No. 1, was permanently suspended, and the capacity of nuclear power generation facilities will be adjusted according to the governments denuclearization policy. In these circumstances, it is necessary to assess the quality of radiation safety management in nuclear power plants in Korea by evaluating the radiation dose associated with them. Materials and Methods: The average annual radiation dose per unit, the annual radiation dose per person, and the annual dose distribution were analyzed using the radiation dose database of nuclear reactors for the last 5 years. The results of our analysis were compared to the specifications of the Nuclear Safety Act and Medical Law in Korea. Results and Discussion: The annual average per unit radiation dose of global major nuclear power generation was 720 man-mSv, while that of Korea's nuclear power plants was 374 manmSv. No workers exceeded 50 mSv per year or 100 mSv in 5 years. The individual radiation dose according to occupational exposure was 0.59 mSv for nuclear workers, 1.77 mSv for non-destructive workers, and 0.8 mSv for diagnostic radiologists. Conclusion: The radiation safety management of nuclear power plants in Korea has achieved the best outcomes worldwide, which is considered to be the result of the as-low-as-reasonably-achievable (ALARA) approach and strict radiation safety management. Moreover, the occupational exposures were also very low.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.