• Title/Summary/Keyword: SUV

Search Result 337, Processing Time 0.021 seconds

Reduction of Aeolian Noise from Roof Rack Cross Bars Using Asymmetric Section Geometry (비대칭 단면 형상을 이용한 루프랙 크로스바의 윈드노이즈 저감)

  • 이정한;이강덕;정승균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1406-1412
    • /
    • 2001
  • Roof racks have become a very popular feature of vehicles as the market demand for SUV's and RV's has increased drastically over the years. Aeolian tone from the cross bars however. could be a source of severe discomfort for the passengers. Both experimental and numerical steps are taken to enhance the understanding of the generation mechanism of the wind noise. A successful reduction of the noise is achieved by imposing asymmetry in the section geometry, which reduces the strength of Karmann vortices shed downstream.

  • PDF

A Study on the Characteristics of Elastomers for Vibration Isolation of Sports Utility Vehicle (스포츠 레저용 차량의 진동절연을 위한 고무제품의 특성에 관한 연구)

  • 사종성;김찬묵
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.671-675
    • /
    • 2001
  • Elastomers, which are engine mounts and body mounting rubbers, are traditionally designed for NVH use in vehicles, and they are designed to isolate specific unwanted frequencies. According to the measurement of the characteristics of engine mounts and body mounting rubbers, dynamic stiffness changes with respect to the driving miles accumulated in engine mounts and initial load in body mounting. This study looks at the variability in same engine mount properties, and the desired dynamic stiffness may increased with driving miles accumulated. And the dynamic stiffness of body mounting rubber changes very stiff above 150Hz.

  • PDF

Application of artificial neural network to differential diagnosis of lung lesion: Preliminary results

  • Lee, Hae-Jun;Lee, Yu-Kyung;Hwang, Kyung-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.1614-1615
    • /
    • 2011
  • It is difficult to differentially diagnose between lung cancer and benign inflammatory lung lesion due to high false positive rate on F-18 FDG-PET. We investigated whether application of artificial neural network to this diagnosis may be helpful. We reviewed the medical records and F-18 FDG PET images of 12 patients, selecting clinical and PET variables such as SUV. For selected variables and confirm, multilayer neural perceptron was applied in crossvalidation method and compared to visual interpretation. Neural network correctly classified the lung lesions in 83%, and reduced greately the false positive rate. However, false negative rate was not influenced. Application of neural network to the differential diagnosis between lung cancer and benigh inflammatory lesion may be helpful. Further studies with more patients are warranted.

Diagnostic Efficacy of FDG-PET Imaging in Solitary Pulmonary Nodule (고립성폐결절의 진단시 FDG-PET의 임상적 유용성에 관한 연구)

  • Cheon, Eun Mee;Kim, Byung-Tae;Kwon, O. Jung;Kim, Hojoong;Chung, Man Pyo;Rhee, Chong H.;Han, Yong Chol;Lee, Kyung Soo;Shim, Young Mog;Kim, Jhingook;Han, Jungho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.882-893
    • /
    • 1996
  • Background : Over one-third of solitary pulmonary nodules are malignant, but most malignant SPNs are in the early stages at diagnosis and can be cured by surgical removal. Therefore, early diagnosis of malignant SPN is essential for the lifesaving of the patient. The incidence of pulmonary tuberculosis in Korea is somewhat higher than those of other countries and a large number of SPNs are found to be tuberculoma. Most primary physicians tend to regard newly detected solitary pulmonary nodule as tuberculoma with only noninvasive imaging such as CT and they prefer clinical observation if the findings suggest benignancy without further invasive procedures. Many kinds of noninvasive procedures for confirmatory diagnosis have been introduced to differentiate malignant SPNs from benign ones, but none of them has been satisfactory. FOG-PET is a unique tool for imaging and quantifying the status of glucose metabolism. On the basis that glucose metabolism is increased in the malignant transfomled cells compared with normal cells, FDG-PET is considered to be the satisfactory noninvasive procedure which can differentiate malignant SPNs from benign SPNs. So we performed FOG-PET in patients with solitary pulmonary nodule and evaluated the diagnostic accuracy in the diagnosis of malignant SPNs. Method : 34 patients with a solitary pulmonary nodule less than 6 cm of irs diameter who visited Samsung Medical Center from Semptember, 1994 to Semptember, 1995 were evaluated prospectively. Simple chest roentgenography, chest computer tomography, FOG-PET scan were performed for all patients. The results of FOG-PET were evaluated comparing with the results of final diagnosis confirmed by sputum study, PCNA, fiberoptic bronchoscopy, or thoracotomy. Results : (I) There was no significant difference in nodule size between malignant (3.1 1.5cm) and benign nodule(2.81.0cm)(p>0.05). (2) Peal SUV(standardized uptake value) of malignant nodules (6.93.7) was significantly higher than peak SUV of benign nodules(2.71.7) and time-activity curves showed continuous increase in malignant nodules. (3) Three false negative cases were found among eighteen malignant nodule by the FDG-PET imaging study and all three cases were nonmucinous bronchioloalveolar carcinoma less than 2 em diameter. (4) FOG-PET imaging resulted in 83% sensitivity, 100% specificity, 100% positive predictive value and 84% negative predictive value. Conclusion: FOG-PET imaging is a new noninvasive diagnostic method of solitary pulmonary nodule thai has a high accuracy of differential diagnosis between malignant and benign nodule. FDG-PET imaging could be used for the differential diagnosis of SPN which is not properly diagnosed with conventional methods before thoracotomy. Considering the high accuracy of FDG-PET imaging, this procedure may play an important role in making the dicision to perform thoracotomy in diffcult cases.

  • PDF

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

$^{18}F$-FDG Colonic Uptake by Oral Anti-Diabetic Drugs Including Metfomin in PET/CT Scan (PET/CT 검사에서 Metformin 성분의 항 당뇨약제에 의한 대장에서의 $^{18}F$-FDG 섭취에 관한 연구)

  • Kim, Sang-Gyu;Park, Hoon-Hee;Kim, Jung-Yul;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.50-54
    • /
    • 2010
  • Purpose: The uptake of $^{18}F$-FDG is often observed in normal cell of colon to patients who have non-insulin-dependent diabetes mellitus and had taken anti-diabetic drugs including Metformin in PET/CT scan. In this study, the region of colon was compared between the patients who took anti-diabetic drugs including Metfomin and other patients who took the other anti-diabetic drugs through SUV measurements. Materials and Methods: A hundred eighty patients were studied. 120 patients who have non-insulin-dependent diabetes mellitus (Including Metformin: 60, Excluding Metformin: 60) and 60 patients as a control group were composed. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16 mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery STe PET/CT Equipment (GE Healthcare, Milwaukee, WI, USA). The highest uptake region was measured SUV among ascending, transverse and descending colon. Results: The values of patients who took the anti-diabetic drugs including Metformin were $6.16{\pm}3.64$ g/mL, $4.41{\pm}2.94$ g/mL, and $5.46{\pm}2.44$ g/mL. The patients who took the anti-diabetic drugs which does not have Metformin were $3.05{\pm}1.39$ g/mL, $2.08{\pm}0.97$ g/mL and $3.15{\pm}1.85$ g/mL. The control group were $2.02{\pm}0.88$ g/mL, $1.68{\pm}0.87$ g/mL and $2.19{\pm}1.88$ g/mL. Conclusion: The effect of the intake of Metformin was observed from the SUV on region of large bowel in this study. Thus, it could be helpful for the results by identifying the ingredient of anti-diabetic drug before the examination and the possibility of interpretation of false positive will be reduced.

  • PDF

Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer (대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능)

  • Park, Eun-Kyung;Kang, Won-Jun;Eo, Jae-Seon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Purpose: Although computed tomography (CT) is widely used for diagnosing liver metastasis from colorectal cancer, diagnostic accuracy of CT is not satisfactory. Magnetic resonance (MR) imaging and F-18 FDG PET has been reported to be superior to CT. However, studies on direct comparison of PET and MR are scarce. We compared the diagnostic accuracy of FDG PET and MR in detecting liver metastasis from colorectal cancer. Materials and Methods: Among 363 colorectal cancer patients who underwent F-18 FDG PET (ECAT, Siemens-CTI, Knoxville; Gemini, Philips, Milpitas, U.S.), 26 patients (M:F=17:9, age=$62{\pm}11$) underwent MR to evaluate suspicious metastatic liver lesions. Finally, 35 liver lesions detected by CT from 26 patients were enrolled for analysis. PET and MR results were compared with pathologic reports, clinical findings or follow-up results. Results: Of the 35 lesions, 18 lesions (51.4%) were diagnosed as liver metastases, while remaining 17 (48.6%) as benign. The sensitivity and the specificity of PET were 94.4% and 94.1%, respectively, compared to 100% and 82.4% for MR. MR and PET was concordant in 30 lesions (85.7%: 17 metastatic (94.4%) and 13 benign (76.5%) lesions. ROC curve analysis revealed maximal SUV of 3.1 as the optimum standard in differentiating metastatic from benign liver lesions (AUC=0.897, p<0.001, sensitivity 83.3%, specificity 94.1%). For small lesions less than 1 cm ln diameter (n=20), diagnostic accuracy of PET was comparable to that of MR. Conclusion: F-18 FDG PET showed good diagnostic performance in detecting liver metastasis from colorectal cancer, which was comparable to MR.

Influences of a Sound Design of Media Contents on Communication Effects - TV-CF Sound Using a BQ-TEST (영상음향의 사운드디자인설계가 커뮤니케이션 효과에 미치는 영향 - TV광고음향을 뇌 지수 분석기법으로 -)

  • Yoo, Whoi-Jong;Suh, Hyun-Ju;Moon, Nam-Mee
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.602-611
    • /
    • 2008
  • The sound design performed in the production of media contents, such as TV, movie, and CF, have been conducted through the experienced feeling of some experts in the aspect of auditory effects that communicates stories. Also, there have been few studies of the quantitative approach and verification to apply visual and auditory effects felt by users. This study is a non-equivalent control group pretest-posttest design and investigates the difference in communication effects in which the difference in a sound design in the production of media contents that affects users. This study analyzed the brain quotient (BQ) obtained by the measurement of brain waves during the watching of an experiment image (track A) designed by using a 60-second TV CF only and an experiment image (track B) designed by sound effects and music and investigated which sound design represents differences in communication effects for users. The results of this investigation can be summarized as follows: First, in the results of the comparison of the attention quotient (ATQ), which is the BQ of recognition effects, between A and B tracks, the track A showed a higher difference in activation than the track B. It can be analyzed that the sound design based on music showed higher levels in attention and concentration than that of the sound effect design. Second, in the results of the comparison of the emotional quotient (EQ), which is emotional effects, between A and B tracks, the track A represented a higher difference than the track B. It means that the sound design based on music showed higher contribution levels in emotional effects than that of the design based on sound effects. Third, in the results of the comparison of the left and right brain equivalent quotient (ACQ), which is memory activation effects, between A and B tracks, there were no significant differences. In the results of the experiments, although there are some constraints in TV CF based on the conventional theories in which sound effects based design affects strong concentration, and music based design affects emotional feeling, the music based design may present more effects in continued concentration. In addition, it was evident that the music based design showed higher effects in emotional aspects. However, it is necessary to continue the study by increasing the number of subjects for improving the little differences in ACQ. This study is useful to investigate the communication effects of the sound based design in media contents as a quantitative manner through measuring brain waves and expect the results of this study as the basic materials in the fields of sound production.

Change of FDG Uptake According to Radiation Dose on Squamous Cell Carcinoma of the Head and Neck (두경부종양에서 방사선조사량에 타른 FDG-PET의 변화양상)

  • Lee Sang-wook;Kim Jae-Seung;Im Ki Chun;Ryu Jin Sook;Lee Hee Kwan;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Yoon Sang Min;Song Siyeol;Park Jin-hong;Moon Dae Hyuk;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.98-105
    • /
    • 2004
  • Purpose : To evaluate whether positron omission tomography (PET) with 2-[F-18]fluoro-2-deoxy-D-giucose(FDG) can be used to predict of early response to definitive aim radlotherapy (RT) in squamous cell carcinoma of the head and neck using response rate and locoreglonal control as study endpoints. Materials and Methods : Twenty-two patients with head and neck cancer underwent a FDG-PET study before RT, after a flrst dose of 45 Gy, and after a second dose on more 4han 70 Gy. Standard uptake value (SUV) was calculated for primary tumor (n=22) and neck lymph node (n:10). Attenuation corrected PET scans acquired 60 min after tracer injection were used for evaluation of FDG uptake In tumors. A quantitative FDG uptake index was expressed as Suvlean (corrected for iean body mass). The follow-up time was at least 5 months (range S-1 S months). Results : A total of 22 primary tumors and 10 metastatic lymph nodes were analyzed In FDG-PET. In the first PET study the mean SUVlean the primary tumors and nodes were 5.4 (SD, 2.5) and 4.6 (SD, 2.3), respectively. In the second PET, study peformed after 46 Gy RT the mean SUV in primary tumor and node decreased to 2.9 (SD, 1.9, p<0.001) and 1.7 (SD, 1.3) respectively. in the third PET study peformed at the full dose (more than 70 Gy), RT the mean SUV In the primary tumors and nodes decreased to 2.3 (SD, 1.5, p<0.001) and 1.5 (SD, 1 .1) respectively. Conclusions: FDG uptake In tumors showed a significant decrease after the 45 Gy and more than 70 Gy of RT for squamous cell carcinoma of the head and neck. Reduction of metabolic activity after 46 Gy of radiotherapy Is closely correlated with radiation response.

Kikuchi-Fujimoto disease mimicking malignant lymphoma with 2-[$^{18}F$]fluoro-2-deoxy-D-glucose PET/CT in children

  • Kim, Ji Eun;Lee, Eun Kyung;Lee, Jae Min;Bae, Soon Hwan;Choi, Kwang Hae;Lee, Young Hwan;Hah, Jeong Ok;Choi, Joon Hyuk;Kong, Eun Jung;Cho, Ihn Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.5
    • /
    • pp.226-231
    • /
    • 2014
  • Purpose: Kikuchi-Fujimoto disease (KFD) is a benign disease, which is characterized by a cervical lymphadenopathy with fever, and it often mimics malignant lymphoma (ML). 2-[$^{18}F$]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography ($^{18}F$-FDG PET/CT) is a powerful imaging modality for the diagnosis, staging and monitoring of ML, with the limitations including the nonspecific FDG uptake in infectious or inflammatory processes. This study compared clinical manifestations and PET/CT findings between KFD and ML patients. Methods: We retrospectively reviewed the medical records of 23 patients with KFD and 33 patients with ML, diagnosed histopathologically, between January 2000 and May 2013 at the Department of Pediatrics, Yeungnam University Medical Center. Among them, we analyzed the clinical manifestations, laboratory findings and characteristics, and the amount of $^{18}F$-FDG uptake between 8 KFD and 9 ML patients who had $^{18}F$-FDG PET/CT. Results: The $^{18}F$-FDG PET/CT maximum standardized uptake values ($SUV_{max}$) ranged from 8.3 to 22.5 (mean, 12.0) in KFDs, and from 5.8 to 34.3 (mean, 15.9) in MLs. There were no significant differences in $SUV_{max}$ between KFDs and MLs. $^{18}F$-FDG PET/CT with ML patients showed hot uptakes in the extranodal organs, such as bone marrow, small bowel, thymus, kidney, orbit and pleura. However, none of the KFD cases showed extranodal uptake (P<0.001). $^{18}F$-FDG PET/CT findings of KFD with nodal involvement only were indistinguishable from those of ML. Conclusion: Patients who had extranodal involvement on PET/CT were more likely to have malignancy than KFD.