• 제목/요약/키워드: STEP LENGTH

검색결과 1,044건 처리시간 0.024초

박리 유선의 곡률 변화가 축대칭 후향계단 흐름에 미치는 영향 (Effect of the separating streamline curvature on the axisymmetric backward-facing step flow)

  • 김경천;부정숙;정지융;양종필
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1510-1520
    • /
    • 1996
  • An experimental study on the flow over the axisymmetric backward-facing step was carried out. The purpose of the present study is to investigate the effect of the separating streamline curvature on the reattachment length and to understand the structure of recirculating flows. Local mean and fluctuating velocity components were measured in the separating and reattaching axisymmetric region of turbulent boundary layer on the wall of convex cylinder placed in a water tunnel by using 2-color 4-beam fiber optics laser Doppler velocimetry. The study demonstrates that the reattachment length increases with increasing separating streamline curvature. It is also observed that the reverse flow velocity and turbulent kinetic energy increase with an increase in the separating streamline curvature. In addition, the behavior of maximum turbulent stresses show that the effect of separating streamline curvature is larger in the region of recirculating zone(X/H<2) than in the region of reattachment point.

The Influence of Body Support Treadmill Training with Visual Feedback on the Gait Factors of Stroke Patients

  • Jegal, Hyuk;Kim, Ki Jong;Jun, Hyun Ju
    • 국제물리치료학회지
    • /
    • 제5권2호
    • /
    • pp.708-713
    • /
    • 2014
  • The aim of this research was to investigate how the effects of body supported treadmill training with visual feedback affect the gait factors of stroke patients. Thirty subjects (21 male, 9 female) with a diagnosis of stroke were taken to the hospital to participate in this study. The subjects received body supported treadmill training with visual feedback. The training was executed for 6 minutes, 3 times a day per week for 19 weeks after general exercise. The effects of the visual feedback in the body supported treadmill training were evaluated by measuring the average gait cycle and the average step length of the affected and unaffected. The collected data were statistically analyzed by using a paired t-test. The results of this study were a significant improvement of the average gait cycle and no statistically significant difference of the average step length. The gait cycle average had a statistically significant difference in gender, age, etiology, paretic side, and step length average. There was no statistically significant difference in infarction within etiology. Therefore, it was necessary to apply the easy and simple with the treadmill training in the rehabilitation of the stroke patients. This study will require a variety of outcome measures related to the effects of treadmill training with gait factors.

The Effect of the Streamlined Shoe on Dynamic Gait Change and Foot Plantar Pressure in Healthy Young Adults

  • Shim, Jae-Hun;Koong, Hwa-Soo;Chon, Seung-Chul
    • 대한인간공학회지
    • /
    • 제32권6호
    • /
    • pp.489-494
    • /
    • 2013
  • Objective: This study compared the effects of streamlined shoes on dynamic gait and foot plantar pressure in healthy young adults. Background: With the importance of ankle and lower extremity mechanism, streamlined shoes are contributing to a static gait factors. However, the study of dynamic gait factor is still insufficient. Method: Sixty subjects were randomly allocated to two groups: experimental group(n=30) and control(n=30), respectively. The experimental group performed streamlined shoes, whereas the control group applied usual shoes. Main outcome measurements were assessed contact time, step length and foot plantar pressure using gait analysis with the treadmill. Independent t-test was used to compare the both groups. Results: Compared with control group, contact time of forefoot, midfoot and hindfoot decreased significantly in experimental group(p<.05), Step length increased significantly in experimental group(p<.05). Foot plantar pressure of midfoot and hindfoot increased significantly in experimental group(p<.05), whereas that of forefoot did not show significantly in experimental group(p>.05). Conclusion: Our findings suggest that streamlined shoes was more effective than usual shoes in dynamic gait change including contact time and step length and foot plantar pressure in healthy young adults. Application: The results of streamlined shoes might help to control for the gait of industrial workers.

후향계단 DDES 해석의 길이척도 영향 분석 (EFFECT OF LENGTH-SCALE IN DDES FOR BACKWARD-FACING STEP FLOW)

  • 이충연;사정환;박수형;이은석;이진익;이광섭
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.24-31
    • /
    • 2012
  • Effects of the subgrid length-scale in the Delayed-Detached Eddy Simulation(DDES) are investigated based on the Spalart-Allmaras(S-A) and the k-$\omega$ Shear Stress Transport(SST) turbulence models. Driver & Seegmiller's experimental results are used to validate numerical results. Grid convergence with grid resolution and subgrid length-scale is investigated. The simulation results show that the volume method for the subgrid length-scale is more resistant to unfavorable effects of the grid size in the periodic direction than the maximum method. Using a sufficient grid resolution and an appropriate subgrid length-scale, both S-A based DDES and SST based DDES methods can provide a good correlation with the experimental data.

목보조기의 적용 유무와 보행의 시공간적 변수와의 관계 (The relationship of between apply presence cervical orthosis and temporal parameters of gait)

  • 최한성;이재룡;신화경
    • 대한물리치료과학회지
    • /
    • 제18권3호
    • /
    • pp.33-39
    • /
    • 2011
  • Background : The purpose of this study was to apply cervical orthosis for temporal parameters of gait was to evaluate the effect. Methods : Seven normal adults participated in this study. Before and after applying a cervical orthosis compared to gait. Outcome measure were: general characteristics, temporal parameters of gait. General chacteristics included age, gender, height, weight. Temporal parameters included the Velocity cycle, Stride length, Step length, Cadence cycle, Initial double support time. Temporal parameters of gait, using the motion analysis system for cervical orthosis were evaluated before and after applying. The data was analyzed using SPSS 12.0 software and the Wilcoxon's signed-ranks test. Results : Velocity cycle and Step length were no significant differences(p>0.05). But Stride length, Cadence cycle, Initial double support time were significant(p<0.05). After apply Cervical orthosis in gait, Stride length and Initial double support time was decreased and Cadence cycle was increased. Conclusion : Changes in temporal of temporal parameters of gait was apply a cervical orthosis with the limitations of vision due to take effect. Therefore, Cervical orthosis does not interfere with the normal gait pattern by limiting the Range of Motion so that we consider to apply.

  • PDF

뇌졸중 환자의 보행 대칭성과 기능적 균형 및 보행과의 상관관계 연구 (Relationship Between Gait Symmetry and Functional Balance, Walking Performance in Subjects with Stroke)

  • 김중휘
    • The Journal of Korean Physical Therapy
    • /
    • 제26권1호
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The aim of the present study was to understand the relationship between gait symmetry and functional balance, walking performance in stroke patients and to makes recommendation regarding the most suitable measure for standardization of expression of spatiotemporal gait symmetry. Methods: 45 subjects with stroke (31 men, 14 women, $57.3{\pm}10.3$ years old) participated in this study. Gait symmetry was calculated by equations of symmetry ratio (SR) and symmetry criterion (SC) for stance time, swing time, single leg support time (SLST), step length, and stride length. Spatiotemporal parameters were measured respectively by walkway system ($GAITRite^{TM}$ system). Limit of stability (LOS) by using forceplate (Balance Performance Monitor) during voluntary weight displacement and Berg Balance Scale (BBS) were measured as functional balance and Timed Up and Go test (TUG) and Functional Ambulation Category (FAC) were assessed as functional walking. Results: SR in stance time and swing time was correlation with BBS, TUG and FAC (p<0.05). SR in SLST only with BBS (p<0.01), SR in step length only with FAC (p<0.05). SC in stance time was correlation with BBS and TUG (p<0.05). SC in swing time and SLST with BBS, TUG and FAC (p<0.01), SC in step length with TUG and FAC (p<0.01), SC in stride length with BBS and FAC (p<0.01). Conclusion: Gait symmetry in spatiotemporal gait parameters provides meaningful information about functional balance and walking performance in stroke subjects. Our analysis may support the recommendations of the symmetry criterion as equation for standardization of gait symmetry.

에폭시 코팅 처리된 PS강선의 정착부착성능 실험 (Tests on Transfer Bond Performance of Epoxy Coated Prestressing Strands)

  • 유승룡
    • 콘크리트학회지
    • /
    • 제6권1호
    • /
    • pp.89-100
    • /
    • 1994
  • 프리스트레스 프리텐숀 보의 전달길이를 위하여 콘크리트의 변형율에 의하여 부착력을 계측하는 간접적인 방법을 일반적으로 사용하여 왔다. 이 트랜스퍼 실험은 실제 보에서 행하여지므로, 실제 상태의 정착부착력을 계측할 수 있다는 장점이 있으나, 최대 정착부착응력과 부착강비를 구하기 난해하며, 그 결과가 매우 분산되어 있으므로, 구조 설계자가 안전한 적정기준을 이해하고 선택하기 어렵다. 콘크리트의 변형을 측정하지 않아도 PS 강선의 정착부착 성능을 얻을 수 있는 대안을 소개하였다. 실제 보에서 PS강재의 긴장을 풀 때와 유사한 상황에서 정축부착 응력을 직접 구하였다. 하중재하부에서 풀려진 PS강선의 긴장력은 하중재하부쪽 강선의 단면증가를 가져오고, 콘크리트 블록에 정착부착력을 발생시키며, 다른 방향(고정부 쪽)으로 슬립을 유발시킨다. 두 개의 중공 로드셀로 양단하중을 최대 부착응력 또는 전면슬립이 일어날 때까지 계측하였다. 프리텐션 콘크리트보의 정착부착 길이를 구하기 위하여 이 방법을 기존의 트랜스퍼 실험방법과 병행하여 사용할 것을 제안한다.

편측성 걸음걸이 트레드밀 훈련이 만성 뇌졸중 환자의 보행 속도와 대칭성 회복에 미치는 효과 (Effects of Unilateral Step Treadmill Training on the Gait Speed and Recovery of Gait Symmetry in Patients with Chronic Stroke)

  • 이지연;천승철
    • 대한통합의학회지
    • /
    • 제10권4호
    • /
    • pp.145-151
    • /
    • 2022
  • Purpose : Stroke patients exhibit abnormal walking patterns such as slow walking speed and asymmetrical walking values. The recovery of symmetrical walking in the stance phase using a treadmill means improvements in walking speed and asymmetrical walking. The purpose of this research was to investigate the effect of unilateral step treadmill training (USTT) on gait speed and the recovery of symmetrical walking in chronic stroke patients. Methods : Fifteen patients (11 men and 4 women) with chronic stroke participated in this study. The 10-meter walk test (10MWT) and GAITRite system were used to determine the intervention-related changes in gait speed and symmetrical walking values such as non-paretic step length (NSL), non-paretic step time (NST), paretic single-support time (PSST), step length asymmetry (SLA), and step time asymmetry (STA) after USTT. All participants completed USTT and underwent measurements at 3 different times: at pretest, posttest, and the follow-up test. Repeated-measures analysis of variance was used to compare walking speed and asymmetrical walking values. The statistical significance level was set at p<.05. Results : Walking speed by 10MWT (p<.05) showed significant improvements after USTT as follows: at pretest and posttest (p<.05), posttest and follow-up test (p<.05), and pretest and follow-up test (p<.05). Recovery of symmetrical walking patterns such as NSL (p<.05), NST (p<.05), and SLA (p<.05) were observed after USTT. However, no significant improvements were found in PSST (p>.05) and STA (p>.05) in symmetrical gait. Conclusion : This study suggests that USTT may have a positive effect on walking speed and symmetrical walking patterns in chronic stroke patients. Thus, this study contributes to the existing knowledge about the usefulness of USTT for the effective management of patients with chronic stroke. Further studies are needed to generalize these findings.

모바일 장치용 MEMS 기반 보행항법시스템을 위한 맵매칭 알고리즘 (Map-Matching Algorithm for MEMS-Based Pedestrian Dead Reckoning System in the Mobile Device)

  • 신승혁;김현욱;박찬국;최상언
    • 제어로봇시스템학회논문지
    • /
    • 제14권11호
    • /
    • pp.1189-1195
    • /
    • 2008
  • We introduce a MEMS-based pedestrian dead reckoning (PDR) system. A walking navigation algorithm for pedestrians is presented and map-matching algorithm for the navigation system based on dead reckoning (DR) is proposed. The PDR is equipped on the human body and provides the position information of pedestrians. And this is able to be used in ubiquitous sensor network (USN), U-hearth monitoring system, virtual reality (VR) and etc. The PDR detects a step using a novel technique and simultaneously estimates step length. Also an azimuth of the pedestrian is calculated using a fluxgate which is the one of magnetometers. Map-matching algorithm can be formulated to integrate the positioning data with the digital road network data. Map-matching algorithm not only enables the physical location to be identified from navigation system but also improves the positioning accuracy. However most of map-matching algorithms which are developed previously are for the car navigation system (CNS). Therefore they are not appropriate to implement to pedestrian navigation system based on DR system. In this paper, we propose walking navigation system and map-matching algorithm for PDR.

Characteristics of Flame-holding in a Scramjet Combustor with a Cavity

  • Tanaka, Hideyasu;Takahashi, Shuhei;Uriuda, Yoshitaka;Wakai, Kazunori;Tsue, Mitsuhiro;Kono, Michitaka;Ujll, Yasushige
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.55-61
    • /
    • 2004
  • Numerical simulations were conducted in a rectangular scramjet combustor with a cavity and/or a step in order to investigate their performances for flame-holding. Flow structures and OH radical profiles in the cavity and the step were calculated. The calculated results showed that the cavity generated a larger recirculation zone than the step that had the same depth. Additionally, the combustor with a cavity could make a large low-velocity area than the combustor with a step. The cavity performance was determined by its depth and length. The cavities with too large or too short length did not work effectively, and a certain aspect ratio showed high performance for flame-holding. There was a minimal depth under which the cavity did not work as flame-holder. The fuel injections upstream the cavity and inside the cavity were also tested to investigate the effects on the cavity performance. The result showed that the fuel injection inside the cavity reduced reaction areas and residence time. Therefore, the upstream injection was preferable to the inside injection.

  • PDF