• Title/Summary/Keyword: STATic synchronous COMpensator

Search Result 134, Processing Time 0.027 seconds

New Performance Analysis of SSSC with EMPT Simulation and Scaled-model Experiment (EMTP 시뮬레이션과 축소모형 실험에 의한 SSSC의 성능 해석)

  • Kang, Jung-Gu;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.524-530
    • /
    • 1999
  • This paper describes performance analysis techniques for SSSC using computer simulations with EMPT and experiments with a hardware scaled-model. A switching-level simulation model with EMTP was developed for the SSSC connected in series with the transmission line. The increase of transmission capability and dynamic performance was analyzed with the simulation model. The simulation results were reverified by experimental works with a hardware scaled-model. The developed analysis techniques can be used for designing and evaluating actual system of SSSC.

  • PDF

The Digital Butterworth Filter of STATCOM for detecting negative sequence components of Unbalanced Load currents (불평형보상용 STATCOM의 역상분 전류 검출을 위한 디지털 버터워쓰 필터)

  • Lim, Su-Saeng;Lee, Eun-Woong;Son, Hong-Kwan;Kim, Seok-Kon;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.333-335
    • /
    • 2000
  • STATCOM(static synchronous compensator : one of the custom power equipment) can be used for balancing unbalanced loads. Compensation current references are given by the analysis of the unbalanced 3-phase currents. And for detecting negative-sequence components, a digital Butterworth Filter is designed. Finally a negative sequence component of an unbalanced load current is acquired using the digital Butterworth Filter.

  • PDF

Series Compensation Analysis of Transmission Line using Inverter-type Var Compensator (인버터식 무효전력보상기에 의한 송전선로의 직렬보상 특성해석)

  • 한병문;한경희;신익상
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.28-35
    • /
    • 1997
  • 본 논문에서는 송전선로에 직렬로 삽입되어 선로의 리액턴스를 동적으로 보상하는 인버터식 직렬보상기에 대한 동적 응동 해석을 기술하고 있다. 이 직렬보상기는 다중펄스로 동작하는 전압원인버터와 결합변압기, 그리고 제어장치로 구성되어 있으며, 점호각을 조절하여 선로의 리액턴스를 가변하고 용량성 뿐만 아니라 유도성 보상도 가능하다. 이 보상기로 선로의 리액턴스를 감소시키면 전송 유효전력의 증각가 가능한데, 이러한 효과를 본 논문에서는 단일기-무한대-버스 전력계통에 대해 EMTP를 이용한 시뮬레션으로 확인하였으며, 또한 축소모형 제작과 실험을 통해 실험적으로 확인하였다.

  • PDF

Grid Voltage Regulation with MMC-HVDC System

  • Quach, Ngoc-Thinh;Jeong, Woo-Cheol;Yang, Hang-Jun;Choi, Jong-Yun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.146-147
    • /
    • 2014
  • This paper presents an operation of the modular multilevel converter-high voltage direct current (MMC-HVDC) system as a Statcom to support the grid voltage. The advantage of the MMC-HVDC system is that it can control the active and reactive powers independently. The proposed control scheme will be designed by combining this performance and the control method of the Statcom. The grid voltage is regulated by the control of the reactive power, meanwhile the active power is controlled according to its applications. The simulation results based on the PSCAD/EMTDC simulation program will evaluate the effectiveness of the control scheme.

  • PDF

Installation and Demonstration of 1 MVA STATCOM (1 MVA STATCOM의 설치 및 실증운전)

  • Lee, Doo-Young;Jung, Hong-Ju;Kim, June-Sung;Choi, Jong-Yun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.160-161
    • /
    • 2012
  • (주)효성에서 자체 설계 및 개발한 FACTS(Flexible ACTransmission System) 기기중 하나인 1 MVA STATCOM(Static synchronous Compensator)은 전압 안정도 개선 및 역률제어를 통해 계통전력품질을 향상시킨다. 현재 개발된 1 MVA STATCOM은 제주 행원 풍력단지 내 풍력 발전기 14호기가 연계된 22.9 kV 계통에 병렬접속 되어있으며 현재 실증 운전 중에 있다. 본 논문에서는 1 MVA STATCOM의 설치 및 실증 운전사례를 소개한다.

  • PDF

Study for the selection of the optimal placement for STATCOM, using IPLAN (IPLAN을 이용한 STATCOM의 최적위치선정에 관한 연구)

  • Kim Won Kyu;Gu Min Yan;Baek Young Sik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.171-173
    • /
    • 2004
  • This paper presents the selection of optimal placement for STATCOM (Static synchronous Compensator) which is one of the FACTS (Flexible Alternating Current Transmission System) devices, considering line contingency. Line contingency ranking is gotten by using sensitivity of load margin. According to line contingency ranking line contingency was considered. And IOP (Index for selecting optimal Placement of STATCOM) is calculated by the variation of each bus's reactive mum for several line contingencies. The bus where has the biggest value of lOP is the most optimal placement to install STATCOM for voltage stability. IPLAN is used to program this part which get IOP. This study is carried out on the modified IEEE14 Bus Test System to confirm the efficiency of the method.

  • PDF

Study on Power Capacity Design of Active Controller for Distribution System Reconfiguration (배전망 재구성을 위한 능동 제어기 용량선정 연구)

  • Jeong, Da-Woom;Kim, Soo-Yeon;Park, Sung-Jun;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.328-329
    • /
    • 2019
  • 급격한 전력 수요의 증가로 인한 송전 용량 부족 시, 수용가에 원활한 전력 공급을 위하여 타 배전 선로와 연계 운전을 통해 부족한 전력 공급이 이루어진다. 이때 각각의 연계 지점 전압 정보가 불일치할 시, 선로에 돌입 전류 및 순환 전류가 야기되어 안정적인 전력 공급에 어려움이 있다. 문제 대책 방안으로 선로에 SSSC(Static Synchronous Series Compensator) 기반의 능동 제어기를 구축하여 배전망을 재구성함으로써, 전압 안정도를 향상시킨다. 따라서 본 논문에서는 제어기의 최적화된 용량 선정을 통하여 효율적인 연계 운영을 시행하였으며, 제안하는 이론을 Simulation Tool을 통해 검증하였다.

  • PDF

Analysis of the Injected Zero-Sequence Voltage for Improving Dynamics of Energy Balancing Control with Wye-Connected CHB Converter (Y 결선 CHB 컨버터 에너지 균형 제어 동특성 향상을 위한 주입 영상분 분석)

  • Kim, Jae-Myeong;Kim, Ye-Rin;Kim, Heung-Geun;Jung, Jae-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.336-337
    • /
    • 2020
  • Static synchronous compensator(STATCOM)은 무효전력을 공급하여 외란을 완화하는 등 전력 품질을 향상시켜 전력 계통을 안정화하는 시스템이다. Cascaded H-bridge(CHB) 컨버터는 멀티레벨 구조를 가지므로 STATCOM 시스템 적용에 많은 이점이 있다. 하지만, 이러한 멀티레벨 CHB 컨버터의 안정적인 동작을 위해서는 균형 제어가 필수적이다. 본 논문에서는 Y 결선 CHB 컨버터의 레그 에너지 균형 제어에 사용되는 주입 영상분 전압에 대하여 분석하고 균형 제어의 동특성 향상을 위한 전향 보상 계산 방법을 제안하였다. 제안한 방법을 적용하여 부하 불평형뿐만 아니라 계통 사고로 인한 계통 및 부하 동시 불균형에서도 안정적으로 시스템을 동작할 수 있다. 마지막으로 제안한 방법에 대한 수학적 타당성을 제시하고, 50MVA의 실제 스케일의 시뮬레이션을 통해 제안하는 방법을 검증하였다.

  • PDF

Influence Analysis of Grid Connected Wind Power Generator by Line Constants (풍력발전 계통연계시 선로정수에 따른 계통 영향 분석)

  • Choy, Young-Do;Kwak, No-Hong;Jeon, Young-Soo;Jeon, Dong-Hoon;Han, Byung-Moon;Yun, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.249-250
    • /
    • 2008
  • 본 논문은 고창 전력품질 실증시험장에서 실 계통 연계를 위해 시험 중인 1.5M급 풍력발전 시뮬레이터의 선로정수를 PSCAD/EMTDC를 이용하여 모의하고 선로정수에 따른 풍력발전시스템이 계통에 미치는 영향을 분석하는데 중점을 두었다. 현재 고창에 설치되어있는 전력품질 실증시험장은 22.9kV 급전선에 SSTS(Synchronous Static Transfer Switch)의 한쪽 스위치로 직접 연결되어있으며 다른 한 쪽은 전력계통에서 발생되는 다양한 형태의 이벤트를 발생시키는 SSHG(Sag Swell Harmonics Generator)를 통하여 연결되어있다. 전력품질 향상기기중 하나인 DVR(Dynamic Voltage Restorer)는 SSTS의 부하쪽으로 직렬로 연결되어있으며 delta-wye 변압기를 통해 정류기 부하와 APF(Active Power Filter), 그리고 순저항부하와 유도성부하가 연결되어 있고 또한 SSHG를 통하여 연결된 배전선에는 DSTATCOM(Distribution Static Compensator)가 병렬로 연결되어있다. 본 논문에서는 고창에 있는 풍력발전 시뮬레이터와 동일하게 PSCAD/EMTDC로 구성하였으며 선로정수를 모델링 하기 위해 선로모델을 10Km, 20Km, 30Km, 40Km,로 설정하여 선로정수에 따른 계통영향을 분석하여 풍력발전 시뮬레이터에서 모의가능 한 선로정수 값을 제시한다.

  • PDF

Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM (전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용)

  • Kim, Jun-Sang;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Jun-Kyung;Jung, Hyun-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.