Abstract
An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.
Keywords
Single-phase distributed-STATCOM; Voltage drop; Railroad feeding system;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Keiji KAWAHARA, 'Compensation of Voltage Drop Using Static Var Compensator at Sectioning Post on AC Electric Railway System', PCC-Nagaoka'97, pp. 955-960, 1997
2 KOTRA, 'Kyung-bu Line Chochiyoun-Daeku Trasmission/Distribution Project Report', 2005
3 Ko-rail, 'The Electric Locomotive', 2004
4 P. C. Tan, 'Voltage Form Factor Control and Reactive Power Compensation in A 25[kV] Electrified Railway System Using A Shunt Active Filter Based On Voltage Detection', IEEE PEDS 2001-INDONESIA, p.605-610, 2001
5 Zhu Yongqing, 'Balancing Compensation of Unbalanced Based on Single-Phase STATCOM', Tsinghua University Beijing
6 Walmir Freitas, 'Impacts of AC Generators and DSTATCOM Devices on the Dynamic Performance of Distribution Systems', IEEE Transactions of power delivery, VOL. 20. pp. 1493-1501, 2005   DOI   ScienceOn
7 Mohan, 'Power Electronics', pp. 211-225
8 Hun-soo Jung, 'Compensation of Voltage Drop Using the TSC-SVC in Electric Railway Power Supply System', Journal of KIIEE, VOL. 16, pp. 29-36, 2002
9 Seung-Hyuk Lee, 'Compensate Voltage Drop for Autotransformer-Fed AC Electric Railroad System with Single-Phase STATCOM', Journal of the Korean Institute and Electrical Installation Engineers Vol. 16, No5, pp. 53-60, 2002   DOI   ScienceOn
10 Joon-Ho Choi, 'A Study on the Application of UPQC in AC Railway System', Journal of KIIEE, VOL. 18, NO.6, pp. 220-229, 2004