• Title/Summary/Keyword: SS removal

Search Result 477, Processing Time 0.027 seconds

Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.

A Study on the Treatment of Paper Making Wastewater Using Submerged biological Film Process (침적 생물막법에 의한 제지폐수처리에 관한 연구)

  • Lee, Tae-Ho;Eun, Jong-Geuk
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2008
  • This study was carried out to get efficient of nutrient removal effects on the treatment of paper making wastewater using submerged biological film process. The concentration of average BOD at raw wastewater was $324mg/{\ell}$ and COD was $435mg/{\ell}$. The average BOD of effluent was maintained $24.2mg/{\ell}$ and average COD was $37mg/{\ell}$. The concentration of average T-N at raw wastewater was $16.5mg/{\ell}$ and T-P was $1.2mg/{\ell}$. The average T-P of effluent was maintained $2.3mg/{\ell}$ and average T-P was $0.08mg/{\ell}$. The concentration of average SS at influent wastewater was $263mg/{\ell}$. The average SS of effluent was maintained $28.2mg/{\ell}$. The result of this experiment was wastage sludge did generated and the removal efficiency of nutrients were kept equilibrium.

The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant (B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구)

  • Eorn Tae-Kyu;Han Dong-Yueb;Kim Boo-Gil
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

Pilot Scale Test of Non-woven Fabric Filter Separation Activated Sludge Process for Practical Application on Domestic Wastewater Reclamation (파일럿 규모의 침지식 부직포 여재 활성슬러지 공정의 시스템 처리 특성에 관한 연구)

  • Lee, Sang-Woo;Choi, Chul-hoi;Park, Young-mi;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.289-294
    • /
    • 2006
  • A pilot scale non-woven fabric filter separation activated sludge system was investigated for practical application on domestic wastewater reclamation and reuse. The system was operated in A/O (Anaerobic/Oxic) process with submerged filter module in the aerobic compartment. In the test of two types of filter materials ($70g/m^2$ and $35g/m^2$), the initial flux (0.42m/d) could be maintained for about three months by regular air backwashing of $70g/m^2$ filter at 0.3m water head. The removal efficiency of organic matter by the system was BOD 93.3%, CODcr 96.3%, SS 96.7%. The effluent quality was 7.8mg/L, 12mg/L and 5mg/L for BOD, CODcr and SS, respectively. The water quality was enough to meet a standard for domestic reuse without human contact. T-N removal efficiency was 49.9% at internal recycle rate 2Q and C/N ratio 3.3. The removal efficiency of T-P was 50% with average effluent concentration, 2.6mg/L.

Municipal Wastewater Treatment by Submerged Membrane Process (침지형 membrane을 이용한 생활오수처리)

  • 김광남;정순형;정우영;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 1999
  • The removal characteristic of BOD, COD,T-N, and T-P was investigated in municipal wastewater treatment with anoxic and membrane submerged aerobic reactor. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 90 days operation. BOD and COD loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained.In the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 99% respectively.It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

A Study on Water Quality Purification Function by Using Planting Concrete and Porous Concrete (다공성 콘크리트와 식생 콘크리트에 의한 수질정화기능에 관한 연구)

  • Ahn, Tae Woong;Choi, I Song;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.5
    • /
    • pp.271-278
    • /
    • 2008
  • The purpose of this research provides the basic solution about waterfront and promotes the inherent capability, that recoveries both the river and gives the river for water quality to improve plan. In this study, we compare and analysis the slope contact between filter media of the porous concrete and planting concrete. As a result, when appling the porous concrete, it can show the removal efficiency is SS 53%, BOD 39%, COD 20%, T-N 36% T-P 42% and appling planting concrete is SS 58%, BOD42%, COD 26%, T-N 45%, T-P 53%. Therefore, planting concrete is higher removal efficiency (SS 5%, BOD 3%, COD 6%, T-N 9%, T-P 10%) than porous concrete. The experimental results show that using purification filter media on planting concrete is better than on porous concrete, because it have the higher purification filter efficiency. The quality of water improves vegetarian concrete, that can expect the increase of the self-purification capacity and improve the spectacle for providing the waterside and planting of planting concrete. In addition, it can complete and apply the research if having enough time for experimentation and accurate study for mechanism by plant, we can use both planting concrete filter media and the existing dike. As a result, we can gain the better quality of the water of the city's rivers and good economic value, that is spread by all cities applicable technologies. So it can be expected using well for future.

A Study on Treatment of CSOs by Vortex Separator and Continuous Fiber-Filter System (Vortex separator와 연속식 섬유사여과를 이용한 CSOs 처리연구)

  • Lee, Bum-Joon;Na, Ji-Hoon;Kim, Jin-Sung;Joo, Jae-Young;Bae, Yoon-Sun;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.443-451
    • /
    • 2010
  • This study was conducted to confirm the CSOs characteristics, and to estimate treatment efficiency of CSO treatment process. Flowrate was average $53,500m^3$/d, maximum $58,100m^3$/d during dry season, but after rain-fall, the flowrate was increased more than twice that of the dry season. And, water pollution concentrations, such as $COD_{Cr}$, SS, $BOD_5$, TN and TP of after rain-fall, were also increased. Thus, for more efficient treatment of pollutants during rainy season, The vortex separator and continuous fiber filter devices were used. From the results on particle range, removal efficiency of particle was 99.7% at the particle size range of $40{\sim}100{\mu}m$ but decreased as 55-80% at the below $40{\mu}m$. The removal efficiencies of $COD_{Cr}$, SS, TN and TP were approx. 70, 60, 70 and 50, respectively during the dry season and approx. 50, 50, 8 and 18% during the rainy season. Also, when compared with the primary sediment basin, $COD_{Cr}$, SS, TN and TP removal efficiencies were high. especially, at the case of TN and TP, TN was more removed than TP because of higher conversion factor value. But we needed more study for the injection of a coagulants to get more stable treatment efficiency for soluble pollutants. Consequently, This process can be used for CSOs treatment as well as replace the primary sedimentation basin during the dry season.

Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System (산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술)

  • Seo, Seong-nyeo;Kim, Young-taek;Park, Chul-hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

Study on Pollutant Characteristics of Tunnel Cleaning Wastewater and Removal Characteristics of the Pollutants via Settling and Adsorption (터널 세척 폐수 특성 및 분리.흡착 방식에 따른 오염물질 저감 연구)

  • Park, Sang-Woo;Choi, Young-Hwa;Oh, Je-Ill
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • Washed wastewater generated from the intermittent cleaning process of the three tunnel sites located in the Seoul area showed high concentrations of SS, $COD_{Cr}$, T-N, $NH_3-N$, $NO_3-N$, Zn, Cu, Cr(+6), Mn, Mg, Phenol, $CN^-$ and E-Coli based on the water quality analysis. These characteristics of the deteriorative wastewater depend on the sampling method, cleaning frequency, released amount of washing water, inner material of tunnel wall, traffic volume, and type of drainage systems. Gravitational separation experiment of SS with collected tunnel wastewater showed considerable removal of pollutants such as 80% of $COD_{Cr}$, 30% of T-N and 90% of T-P simultaneously. GAC isotherm test was conducted to remove dissolved portion of the pollutants, and resulted in high removal efficiencies above 80% of $COD_{Cr}$, T-N, Zn, Cu, Mn, Phenol, CN in the experimental condition of GAC dosage of $50g/1/{\ell}$.

  • PDF

Performance Study on Pilot-scale Constructed Wetlands in order to Restore Contaminated Stream (오염하천의 정화를 위한 파일럿 규모의 인공습지 적용)

  • Kim, Seung-Jun;Choi, Yong-Su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.546-556
    • /
    • 2006
  • The purpose of this study is to improve the polluted stream water quality by pilot-scale five different constructed wetlands (CWs). Cell 1 to 3 are newly designed 2SFCW (Surface-subsurface flow CW) with 1 to 3 flow shifters (FS) in the middle of the wetland system. Cell 4 and 5 are control CW (CCW), but Cell 5 is the same type as Cell 3. The FS, which converts the route of surface and subsurface flow between two wetlands connected in series, was able to enhance the treatability of TN via nitrification and denitrification and of SS due to filtration and sedimentation. The void fraction and dispersion number of Cell 1, 2 and 3 obtained from the RTD analysis were found to be 0.73 and 0.17, respectively. COD and TP removal efficiencies of Cell 1 to 3 were similar to that of Cell 4 and 5. SS removal efficiencies of Cell 1 to 3 and 5 with FS were 5-10% higher than that of Cell 4 without FS. TN removal efficiencies of Cell 1 to 3 were 3-14% higher than that of Cell 4 and 5. The average $R^2$ values of COD, SS, TN and TP obtained from nonlinear regression analysis were similar to the results of other researchers.