• Title/Summary/Keyword: SS농도

Search Result 525, Processing Time 0.028 seconds

Disintegration of Sewage Sludge Using Mechanical Pre-treatment (기계식 전처리를 이용한 하수슬러지의 가용화)

  • Lee, Chae-Young;Yoo, Hwang-Ryong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.82-90
    • /
    • 2009
  • Disintegration of sewage sludge (SS) was investigated by batch experiments using mechanical pre-treatment. Mechanical disintegration of SS increased the amount of soluble chemical oxygen demand (SCOD), protein and carbohydrate due to the break-up of cell walls. The mechanical disintegration incorporated with alkaline pre-treatment demonstrated higher amount of SCOD compared with mechanical one only. In terms of anaerobic biodegradability, mechanical pretreatment enhanced the anaerobic biodegradation of SS, leading to the methane production improvement. The improvement in BMP for SS treated with mechanical and alkaline-mechanical pre-treatments were 24.1% and 44.5%, respectively. This result suggested that disintegration of SS was effective for improving anaerobic biodegradability.

  • PDF

Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system (합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석)

  • Park, Jin-Kyu;Lee, Nam-Hoon;Kim, Hae-Ryong;Lee, Woong;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

Effects of Coagulants and Ozone Concentration on the Livestock Manure Treatment Efficiency of AOF Process (AOF공정 중 응집제와 오존 농도가 가축분뇨 처리효율에 미치는 영향)

  • Jeong, Sung-Chol;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.311-315
    • /
    • 2016
  • The efficiency of manure treatment was investigated in terms of the pH, BOD, COD, SS, T-N and TP with a variation in the injection amount of PAC, polymer and ozone. The wastewater flow rate to the AOF is of $7.4m^3/hr$ with a reaction time of 30 minutes. The amount of PAC and polymer changed by 30, 35, 40 ml/min, and 30, 40, 50 ml/min, respectively. The amount of ozone injected varied from 110, 125, and $150kg-O_3/hr$. The optimum manure treatment performance was found for a PAC of 35 ml/min for the COD and SS, with polymer of 30 ml/min, and ozone injection of $150kg-O^3/hr$. A substantially optimum dose for each PAC, polymer, and ozone was also found to exist.

Effects of Diluents and Cryoprotectants on Sperm Cryopreservation in Starry Flounder (Platichthys stellatus) (강도다리(Platichthys stellatus) 정자의 냉동보존에 미치는 희석액과 동해방지제의 영향)

  • Lim, Han-Kyu;An, Cheul-Min;Noh, Gyong-Ane;Min, Byung-Hwa
    • Journal of Aquaculture
    • /
    • v.20 no.3
    • /
    • pp.173-177
    • /
    • 2007
  • An experiment was performed to obtain cryopreservation techniques of starry flounder (Platichthys stellatus) sperm. Milt obtained from 24 males were cryopreserved using two diluents, artificial seminal plasma (ASP) and Stein's solution (SS) with three cryoprotectants, dimethyl sulfoxide (DMSO), methanol, and glycerol concentrated from 5% to 20%. Post-thaw sperm activity (motility and/or speed) revealed the highest in 10% DMSO and 15% methanol in ASP and SS as diluent. Motility and speed of cryopreserved sperm were decreased according to increase of glycerol concentration. To conclude, DMSO was a better cryoprotectant than methanol or glycerol for cryopreservation of starry flounder sperm. Glycerol was incongruent cryoprotectant because of toxic to starry flounder sperm. Most cryopreserved spermatozoa without cryoprotectant showed the enlarged head with granulated chromatin and ruptured plasma membrane by freezing and thawing injuries compared with unfrozen normal spermatozoa.

Statistical Analyses of Long-Term Water Quality Variation in the Geumgang-Reservoir: Focused on the TP Load by Migrating Birds Excrement (금강호의 장기 수질 변화요인 분석: 철새배설물에 의한 TP부하의 중요성)

  • Jeong, Yong-Hoon;Kim, Hyun-Soo;Yang, Jae-Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.4
    • /
    • pp.223-233
    • /
    • 2010
  • Spatio-temporal variations of long-term water qualities (COD, SS, $Chl-{\alpha}$, N-related nutrients (TN, TDN, $NO_3^-$, $NH_4^+$), P-related nutrients (TP, TDP, $PO_4^{3-}$)) at two stations (St. SD, St. GG) in the Geumgang Reservoir were investigated from August 2001 to July 2008. Statistical methods such as t-test, factor analysis, and multi-regression analysis were applied to the water quality data in the reservoir as well as mass balances on TP. From the temporal comparisons of the water qualities between 2002 and 2007, average concentrations of $NH_4^+$, $PO_4^{3-}$, and TDP gradually decreased down by 60%, 24%, 52% in 2007. However, those of TP and $Chl-{\alpha}$ increased to 99% and 423% during the period. From the spatial comparisons between the two stations, St. GG showed higher concentrations for all of the N- and P-related nutrients than in St. SD, while opposite result for the $Chl-{\alpha}$. The factor analysis showed that "the seasonal variations of N- and P-related nutrients" were the two dominant factors occupying 49% of total variances of water qualities. Based on this result, multi-regression analysis executed for the two most influential parameters (TP and $Chl-{\alpha}$) focusing on the seasonal variations of these parameters: SS and $Chl-{\alpha}$ has contributed decisively to the concentrations of TP during the wet and dry season, respectively. On the other hand, COD and TP has been important for the $Chl-{\alpha}$ during the wet and dry season, respectively. From the established mass balances of TP loadings in the Geumgang Reservoir, Other Sources (60%) occupied the greatest contribution and Fluvial Input (38%) and Sediment (1%) during the wet season. However, both Fluvial Water (48%) and Other Sources (47%) supplied comparable amount of inputs and Sediment (5%) showed significantly increased input during the dry seasons. Recently especially during the dry winter seasons, migrating bird's excretion was estimated to contribute up to 8% of total TP input and 21% of Other Sources.

Study on Electrical Characteristics of Ideal Double-Gate Bulk FinFETs (이상적인 이중-게이트 벌크 FinFET의 전기적 특성고찰)

  • Choi, Byung-Kil;Han, Kyoung-Rok;Park, Ki-Heung;Kim, Young-Min;Lee, Jong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.1-7
    • /
    • 2006
  • 3-dimensional(3-D) simulations of ideal double-gate bulk FinFET were performed extensively and the electrical characteristics. were analyzed. In 3-D device simulation, we changed gate length($L_g$), height($H_g$), and channel doping concentration($N_b$) to see the behaviors of the threshold voltage($V_{th}$), DIBL(drain induced barrier lowering), and SS(subthreshold swing) with source/drain junction depth($X_{jSDE}$). When the $H_g$ is changed from 30 nm to 45nm, the variation gives a little change in $V_{th}$(less than 20 mV). The DIBL and SS were degraded rapidly as the $X_{jSDE}$ is deeper than $H_g$ at low fin body doping($1{\times}10^{16}cm^{-3}{\sim}1{\times}10^{17}cm^{-3}$). By adopting local doping at ${\sim}10nm$ under the $H_g$, the degradation could be suppressed significantly. The local doping also alleviated $V_{th}$ lowering by the shallower $X_{jSDE}\;than\;H_g$ at low fin body doping.

Fouling Control Technique of Membrane Using Simultaneously Washing Process (동시세정방식을 이용한 막의 fouling 억제기술)

  • Choi, I-Song;Son, Chang-Sun;Kim, Sung-Yoon;Lim, Byung-Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1637-1641
    • /
    • 2009
  • 본 연구는 막공정을 이용하는 수처리기술에 있어서 최대 난점 중의 하나인 fouling 현상을 억제하기 위하여 여과방향의 반대방향에서 여과수를 지속적으로 분사하여 줌으로써 여과와 세정이 동시에 일어나는 동시세정방식을 평가하기 위한 것이다. 실험은 성균관대학교 환경플랜트 내에 pilot 실험지를 조성하여 실시하였으며, 실험원수는 오수처리방류수를 저류하는 연못수와 오수원수를 혼합하여 농도를 조절한 후에 저농도와 고농도 조건에서 실험을 실시하였다. 저농도 조건(SS 10$\sim$20 mg/L)에서는 연못의 HRT를 고려하여 일일 5시간 씩 8일간 가동하였고, 고농도 조건(SS 200 mg/L 이상)에서는 8시간씩 가동하였다. 저농도의 경우에는 가동기간 중 배수가 일어나지 않았고, 일일 운전 종료 후 유지관리를 위한 강제배수만 실시하였다. 고농도에서는 초기에 배수가 짧은 term으로 자주 일어났지만, 20분 이상의 비교적 긴 여과지속시간을 유지하였고 유입수 농도가 낮아지면서 배수타임이 점점 늘어나는 경향을 보였다. 이러한 결과는 동시세정방식에 의한 여과기술에 있어 유입수 농도가 fouling 발생빈도에 크게 영향을 미친다는 것을 의미하며, $5\;{\mu}m$의 미세막에서도 고농도 운전이 가능하다는 사실을 보여준다. 동시세정방식은 Rum Filter의 fouling을 억제하고 지속적인 운전을 가능하게 해주는 핵심기술이다. 세정 시 세정압력설정은 매우 중요한 운전인자 중 하나인데, 세정압력이 너무 클 경우에는 소요되는 동력이 많아져 효율적인 설계 및 운전에 장애요인이 될 수 있고, 너무 낮을 경우에는 세정이 제대로 되지 않고 여과막 내부와 외부의 압력차를 크게 가져와 배수타임이 빨라지는 결과를 초래한다. 따라서 적절한 세정압력을 파악하고 설정하기 위하여 세정압력을 변화시켜가면서 이에 따른 차압의 변화를 관측하여 보았다. 여과막의 공극과 세정압력에 변화를 주면서 실험을 한 결과, 세정압력이 커지면 여과막에 작용하는 부하가 약간 증가하는 것으로 나타났지만, 그 차이가 $0.02\;kg_f/cm^2$으로 나타나, $4.0\;kg_f/cm^2$ 이상의 세정압력에서 적용이 가능한 것으로 나타났다. 또한, 유입유량을 설정하기 위하여 $4.5\;kg_f/cm^2$의 세정압력을 유지한 상태로 유입유량을 점진적으로 증가시키면서 압력의 변화를 관측하였다. $5\;{\mu}m$에서는 180 LPM 및 200 LPM에서, $8\;{\mu}m$에서는 200 LPM에서 자체적으로 설정한 배수차압 상승분인 $0.1\;kg_f/cm^2$를 초과한 것으로 나타났고, $10\;{\mu}m$ 이상에서는 모두 200 LPM이상 처리해도 배수압력에 걸리지 않는 것으로 나타났다. 이러한 결과는 현재 본 시스템에 적용하고 있는 유입유량 기준치를 2배 이상 상회하는 결과로서 추가적인 실험을 통하여 기존 여과기술보다 여과지속시간이길고, 여과 flux가 높은 기술을 개발할 수 있을 것으로 판단된다.

  • PDF

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot - (강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 -)

  • Kang, Mee-A;Choi, Byoung-Woo;Yu, Jae-Jeong
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 2010
  • This study was carried out to produce the characteristics of pollutant loads caused by a cherry tree plot as a nonpoint sources(NPS) unit in agricultural areas. The relationship between rainfall and runoff didn't show a good coefficient with 0.5. Despite precipitation amount was less than 20 mm, runoff occurred with $0.5\;m^3$ because of high rainfall intensity of 8.8 mm/hr. In contrast, runoff was not occurred when precipitation amount was 47.4 mm in one case. In that case the primal effect on runoff was not precipitation amount. Correlation between load of pollutants such as BOD, COD, TN and TP and runoff' volumes showed significantly positive values which were more than r = 0.92 for all pollutants except SS(r = 0.71). SS could be a proper factor for estimating pollutant loads of BOD, COD, TN and TP because of a high correlation more than r = 0.73 between SS load and pollutant loads of BOD, COD, TN and TP. Both Organics and nutrient pollutants could be reduced if we control SS in runoff. The highest concentration of TN was detected in the event which was affected by fertilization activities directly. Therefore fertilization must be considered as a function of impact parameters on TN load in agricultural areas.

Initial Operating Condition of Membrane Bioreactor with PVDF Hollow Fiber and Permeate Reuse (PVDF 중공사막을 이용한 막생물반응기의 초기 운전조건 설정 및 여과수 재활용)

  • Shin, Choon-Hwan;Kang, Dong-Hyo;Park, Hae-Sik;Cho, Hyun-Kil
    • Clean Technology
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • In this paper, 4 bundle modules of PVDF hollow fiber membrane from Woori Tech company (Korea) were manufactured in a treatment capacity of 10 ton/day. A membrane bioreactor (MBR) pilot plant was installed at Sooyoung Wastewater Treatment Plant in Busan. An alternating aeration process was selected to avoid the concentration profile of suspended solid (SS) in the MBR. For stable operation, raw wastewater with mixed liquor suspended solid (MLSS) of about 1,000 ppm, which was in-flowed from the aeration tank of the wastewater treatment plant, was fed and filtered through the pilot plant. Subsequently the pilot plant were washed three times with washing water: once with ethanol solution, once with a solution of 5% NaOCl, and finally with washing water. After the chemical washing, the remaining water in the MBR was fed into the pilot plant. As a result, the SS removal efficiency was found to be more than 99.9%. The amount of filtrate with the aeration tank influent decreased by 16%, compared with that from the initial conditions, giving rise to 30% increase in the suction pressure. These results were used to set up continuous operation conditions. The results from the continuous operation with influent MLSS of 1,900 mg/L showed that the SS removal efficiency was about 99.99% and that the amount of filtrate and the suction pressure were $42{\sim}52L/m^2$ and 16~20 cmHg, respectively, indicating stable operation of the pilot plant. However, for the reuse of wastewater, methods need to be sought to avoid growth of algae which affects the SS removal efficiency at inlet and outlet of the permeate tank.

Calculate of EMC and Runoff Characteristic of Silica Mine (규사광산의 유출특성 및 EMC산정)

  • Choi, Yong-Hun;Won, Chul-Hee;Shin, Min-Hwan;Yang, Hee-Jung;Choi, Jung-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1042-1046
    • /
    • 2009
  • 강원도 홍천군 북방면 능평리에 위치한 규사광산을 2008년 3월부터 12월까지 발생한 강우사상에 대하여 모니터링을 실시하였다. 모니터링 지점은 채광작업과 가공작업이 이루어지는 계곡의 하류로 평시 $500m^2$/day의 유량이 흐르는 작은 소하천이다. 관측된 13회의 총 강우량은 712.6 mm가 발생하였다. 강우강도는 0.5 ${\sim}$ 4.7 mm/hr, 선행무강우일수는 1.2 ${\sim}$ 9.8일로 나타났다. 유출률은 28.0 $^{\sim}$ 98.0 %로 나타났으며, 유출율 98.0 %는 168.0 mm의 많은 양의 강우가 발생한 7월 24일부터 25일까지의 강우사상에서 발생하였다. 채석과 가공작업등의 영향으로 인하여 강우시 다른 오염 물질보다 SS 농도와 EMC가 매우 높고, 범위가 가장 큰 것으로 나타났다. 또한 SS는 강우량과 건기일수에 민감한 영향이 있는 것으로 나타났다. 따라서 규사광산지역은 다른 오염 물질보다 SS를 저감 시킬 수 있는 비점오염저감시설이 필요할 것으로 사료된다. 기상조건에 따른 오염부하와 EMC의 정확한 산정하기 위해서는 장기간의 모니터링을 통한 많은 자료의 수집이 동반되어야 할 필요가 있다. 본 연구에서 조사된 자료와 분석된 결과는 토지이용별 비점오염부하의 산정과 저감기술의 개발에 활용할 수 있으며, 수질오염총량제의 신뢰성을 향상시킬 것으로 판단된다.

  • PDF