• Title/Summary/Keyword: SPR sensor chip

Search Result 19, Processing Time 0.055 seconds

A Study on the Sensitivity of Surface Plasmon Resonance Sensor Chips with Various Material Configurations in Angle and Intensity Detection Modes (공명각 및 반사광 측정 모드에서 다양한 물질 구성의 표면 플라즈몬 공명 센서 칩의 민감도 특성)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.402-407
    • /
    • 2017
  • Characteristics of various material surface plasmon resonance (SPR) chips were investigated in angular interrogation mode and intensity interrogation mode. Among five metals, silver (Ag), gold (Au), copper (Cu), chromium (Cr) and titanium (Ti), three metals, Ag, Au and Cu were paid attention to since their characteristics can be easily analyzed in angular interrogation mode by investigating the change of their reflectance curves according to refractive index change from 1.331 to 1.335. Most of SPR chips with various configurations showed the similar property in angular interrogation mode. The application of the SPR chip made of Ag, Au and Cu or their combinations depends on their reflectance properties. In intensity interrogation mode, the operation range may be limited since the variation of the intensity was not linearly related to refractive index change ranging from 1.331 to 1.335. However, the SPR chip containing high ratio of Ag may be applicable to high sensitive detection due to their sharp reflectance curves in intensity interrogation mode.

Characteristics of Constructed SPR (Surface Plasmon Resonance) Sensor System for the Detection of Salmonella and hIgG Antigen-Antibody Reaction. (살모넬라와 면역글로블린(hIgG)의 항원-항체반응 감지를 위한 표면 플라즈몬 공명형 센서시스템의 특성)

  • Um, N.S.;Koh, K.N.;Hahm, S.H.;Kim, J.H.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.263-270
    • /
    • 1998
  • Surface Plasmon Resonance (SPR) sensor system, has rapid response and high sensitivity, can be applicable for detecting reaction times of many biospecific interactions. A SPR sensor system was constructed to detect the antigen-antibody reactions of salmonella and hIgG (human immunoglobulin G). Sensor chips made of gold thin film were used for detecting biological bindings of antigen and antibody reactions. The antigen and antibody reactions for salmonella and hIgG were carried out with various time intervals to observed characteristics of these reactions using SPR sensor system. The resonance angle shift changes were clearly observed at the time of salmonella or hIgG antibody injection into sample cell since each antibody was self-assembled on gold chip surface of the sensor. It was found that the antibodies of salmonella and hIgG reacted with its sensor chip surface in 10 minutes and 60 minutes respectively. And the antigens of both salmonella and hIgG were bound to its antibody within 1 minute.

  • PDF

Detection of the Fungicide Iprovalicarb Residues Using a Surface Plasmon Resonance Biosensor (표면플라즈몬공명 바이오센서를 이용한 살균제 Iprovalicarb 잔류물의 검출)

  • Kim, Woon-Ho;Cho, Han-Keun;Kyung, Kee-Sung;Kim, Gi-Young
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.50-56
    • /
    • 2009
  • Surface plasmon resonance (SPR) biosensor has been used to detect many biochemical reactions, because this label-free sensor has high sensitivity and rapid response. The reactions are monitored by refractive index changes of the SPR biosensor. Iprovalicarb is protective, curative, and eradicative systemic fungicide introduced by Bayer AG in 1999. It has potential far control of downy mildew infesting onion, cucumber, grape and melon, late blight infesting tomato and potato, and anthracnose infesting watermelon and pepper. It is strictly limited to the maximum residue limit. In this study, the applicability of a portable SPR biosensor (Spreeta, Texas instrument, TX, USA) to detect the iprovalicarb residue was examined. The sensor chip was adopted to detect the reaction of iprovalicarb to immobilized iprovalicarb-antibody. The binding of the iprovalicarb onto the biosensor surface was measured by change of the refractive index (RI). Characteristics of the sensor chip including specificity, sensitivity, stability, and reusability were analyzed. In calibration test for seven levels of iprovalicarb concentration (0.32 to 5,000 mg/L) with three replications, a Sigmoidal model with Hill function was obtained between relative RI value and the iprovalicarb concentration with R-square of 0.998. It took 30 minutes to complete a set of detecting assay with the SPR biosensor.

The Construction of the SPR (Surface Plasmon Resonance) Sucrose Sensor (표면 플라즈몬 공명형 자당 센서의 제작)

  • Um, N.S.;Lee, S.M.;Hahm, S.H.;Koh, K.N.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.279-284
    • /
    • 1998
  • A surface plasmon resonance (SPR) sensor system for the determination of sucrose concentration was constructed with a gold thin film sensing chip. The properties of gold thin film are critical factors in exciting surface plasmon resonance phenomena. Therefore in the present paper, the fabrication conditions of gold thin film were investigated to optimize the SPR phenomena. The optimum thickness was obtained as $545{\AA}$ with $43.75^{\circ}$ resonance angle and good surface roughness limitation. about $3{\AA}$. The linear resonance angle shifts and rapid response were observed from the sucrose concentrations ranged from 0 to 40wt%.

  • PDF

A portable surface plasmon resonance sensor system for detection of C-reactive protein using SAM with dimer structure (소형 표면 플라즈몬 공명 센서와 이합체 구조를 가진 SAM을 이용한 CRP 검출)

  • Sin, Eun-Jung;Joung, Eun-Jung;Jo, Jin-Hee;Hwang, Dong-Hwan;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.456-461
    • /
    • 2010
  • The detection of C-reactive protein(CRP) using self-assembled monolayer(SAM) was investigated by a portable surface plasmon resonance(SPR) sensor system. The CRP is a biomarker for the possible cardiovascular disease. The SAM was formed on gold(Au) surface to anchor the monoclonal antibody of CRP(anti-CRP) for detection of CRP. Sequence injection of the anti-CRP and bovine serum albumin(BSA) into the sensor system has been carried out immobilize the antibody and to prevent non-specific binding. The portable SPR system has two flow channels: one for the sample measurements and the other for the reference. The output SPR signal was increased with the injection of the anti-CRP, BSA and CRP due to binding of the proteins on the sensor chip. The valid output SPR signals was linearly related to the critical range of the CRP concentration. The experimental results showed the feasibility of the portable SPR system with newly developed SAM to diagnose a risk of the future cardiovascular events.

Development, Validation, and Application of a Portable SPR Biosensor for the Direct Detection of Insecticide Residues

  • Yang, Gil-Mo;Cho, Nam-Hong
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.1038-1046
    • /
    • 2008
  • This study was carried out to develop a small-sized biosensor based on surface plasmon resonance (SPR) for the rapid identification of insecticide residues for food safety. The SPR biosensor module consists of a single 770 nm-light emitting diodes (LED) light source, several optical lenses for transferring light, a hemisphere sensor chip, photo detector, A/D converter, power source, and software for signal processing using a computer. Except for the computer, the size and weight of the sensor module are 150 (L)$\times$70 (W)$\times$120 (H) mm and 828 g, respectively. Validation and application procedures were designed to assess refractive index analysis, affinity properties, sensitivity, linearity, limits of detection, and robustness which includes an analysis of baseline stability and reproducibility of ligand immobilization using carbamate (carbofuran and carbaryl) and organophosphate (cadusafos, ethoprofos, and chlorpyrifos) insecticide residues. With direct binding analysis, insecticide residues were detected at less than the minimum 0.01 ppm and analyzed in less than 100 sec with a good linear relationship. Based on these results, we find that the binding interaction with active target groups in enzymes using the miniaturized SPR biosensor could detect low concentrations which satisfy the maximum residue limits for pesticide tolerance in Korea, Japan, and the USA.

Impact of pH on the response of bovine serum albumin to gold surface plasmon resonance chip (소 혈청 알부민의 금 표면 플라즈몬 공명 칩과의 반응에 대한 pH의 영향)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.326-330
    • /
    • 2021
  • Reactions between gold (Au) surface plasmon resonance (SPR) chips and bovine serum albumin (BSA) dissolved in solutions of different pH were investigated. The charge on the BSA depends on the pH of the solution in which it is dissolved. Thus, dissolving BSA in different pH solutions resulted in different charges of BSA. Among the BSA dissolved in solutions with pH 4.01, 7.4, and 10.01, the SPR response was the highest for BSA dissolved in the solution of pH 4.01. To eliminate the response variation owing to the difference in the refractive indices of the solutions, phosphate buffered saline (PBS) was injected into the system after the reaction of BSA with the Au SPR chip had happened. In this case too, the BSA dissolved in the solution with pH 4.01 exhibited the highest response. This may be attributed to the non-uniform distribution of ionic patches on the BSA, which can induce electrostatic attraction to the surface even though BSA has a positive charge at pH 4.01, and the absolute values of the net charge of BSA at pH 4.01 and 7.4 were very close.

Imaging of self-assembled monolayers by surface plasmon microscope (표면 플라즈몬 현미경을 이용한 자기조립 단분자막의 이미징)

  • 표현봉;신용범;윤현철;양해식;김윤태
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Multi-channel images of 11-MUA(11-Mercaptoundecanoic acid) and 11-MUOH(11-Mercaptoundecanol) self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. The patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each point on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching, which are common in the detection methods based on fluorescence.