• 제목/요약/키워드: SPDs

검색결과 53건 처리시간 0.024초

종속 접속된 산화아연바리스터 기반의 서지방호장치의 협조 (Coordination of Cascaded Metal Oxide Varistor-Based Surge Protective Devices)

  • 김태기;신희경;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.70-77
    • /
    • 2015
  • This paper describes the experimental results obtained from various installation conditions of cascaded metal oxide varistor(MOV)-based SPDs with the objectives to analyze the coordination of the cascaded surge protective devices(SPDs) and to propose the proper selection and installation methods of the cascaded SPDs. The residual voltage, discharge current and energy sharing between the upstream and downstream SPDs in the $10/350{\mu}s$ direct lightning current wave were measured and discussed. The coordination of cascaded MOV-based SPDs is closely related to the varistor voltage and installation methods of SPDs. In cascaded SPDs without dedicated decoupling elements, the natural impedance of leads connecting two SPDs can act as a decoupler for the coordination of MOV-based SPDs. Even if the varistor voltage of the upstream SPD is higher than that of the downstream SPD at long distances between two SPDs, the energy coordination of cascaded SPDs could effectively be fulfilled in the conditions of large surge currents and the optimum voltage protection level can be achieved. Consequently, if the distance between voltage limiting type SPDs is long, the coordination of the cascaded SPDs should be determined by taking into account the decoupling effects due to the intrinsic inductance of leads connecting the upstream and downstream SPDs.

종속 접속된 전압제한형 SPD의 직격뢰 서지전류에 대한 에너지협조 (Energy Coordination between Cascaded Voltage Limiting Type SPDs in Surge Currents due to Direct Lightning Flashes)

  • 이복희;엄상현
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.68-75
    • /
    • 2014
  • Cascaded applications of surge protective devices(SPDs) are required in order to reduce the stress on the electrical and electronics equipment being protected, and the energy coordination between the cascaded SPDs is very important. This paper deals with the experimental results obtained from the installation conditions of full-scale SPDs. The energy coordination between the upstream Class I SPD and the downstream Class II SPD was measured using a $10/350{\mu}s$ impulse current due to direct lightning flashes. The distances between the cascaded SPDs were 3, 10, and 50m, and the maximum test current was 12.5kA. As a result, the energy sharing between cascaded SPDs was dependent on the voltage protection level of each SPD and the distance between two SPDs. An overview of how to select SPD ratings in applications of cascaded SPDs system was discussed based on the energy coordination between the two SPDs. The proposed test results for the energy coordination between two-stage cascaded SPDs can be used in effective applications of SPDs.

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.

전원계통의 접지방식에 따른 서지보호기의 보호효과 (Protection Effects of Surge Protective Devices According to Types of system Groundings)

  • 이복희;이동문;강성만;이수봉
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.66-71
    • /
    • 2003
  • 소형의 반도체와 회로로 구성되어진 전자기기는 뇌과전압으로부터 ZnO 바리스터, 지너다이오드, 가스방전관과 같은 서지보호장치 (SPDs)에 의해 보호되고 있다. 그러나 SPD의 제한전압은 SPD의 설치방법에 따라 커다란 영향을 받는다. 본 논문에서는 전원계통의 접지방식에 따른 SPD의 보호효과에 대하여 실험적으로 검토하였다. 독립접지는 SPD의 설치방법에 있어서 그다지 바람직하지 않다. 또한 가스방전관보다 ZnO 바리스터의 한 점을 공통접지하는 것이 더 효과적이다. SPD의 단자에 공통접지하는 것이 SPD의 설치방법에 있어서 가장 효과적임을 제안하였다.

2단 종속 SPD시스템의 보호특성 (Protection Characteristics of Two-Stage Cascade SPD Systems)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.95-103
    • /
    • 2013
  • Protection of the electrical and electronic equipment against surges in low voltage AC power distribution systems is based on wide applications of surge protective devices(SPDs). Cascade application of SPDs located at the service entrance of a building and near sensitive equipment is intended to ensure the optimal voltage protection level and energy sharing among cascade SPDs. In this paper, when surges impinge at the service entrance of the building of interest, the protection characteristics of two-stage cascade SPD systems were investigated. The influence of the distance between the upstream and downstream SPDs on the voltage protection level and energy sharing of the two-stage cascade SPD systems were analyzed experimentally. It was found that the energy sharing of two-stage cascade SPD systems strongly depends on the distance between the two SPDs and the component of SPD. As the distance between the two SPDs increases, the energy absorbed by the upstream SPD increases while the energy absorbed by the downstream SPD decreases. Consequently, it is desirable to select the upstream and downstream SPDs having the proper energy capability with due consideration of the distance between the two SPDs.

전원선용 SPD의 효과적인 설치기법 (An Effective Approach of Installation of Surge Protective Devices for AC Mains)

  • 이동문;정동철;이승칠;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2229-2231
    • /
    • 2005
  • Recently, damages of electronic equipments due to lightning surges coming from AC power lines are increasing. In this work, to propose the effective installation methods of surge protective devices(SPDs), the protective performances of SPDs in actual-sized test circuits were experimentally investigated. In order to obtain the lowest limiting voltage and best protection, long leads of SPDs in installation practices are significantly undesirable. An effective installation method of SPDs for AC mains was proposed. The way of installing SPDs at every branch circuits is more effective than that of installing a SPD near the point of entry.

  • PDF

보호거리에 따른 전압제한형 SPD의 보호효과에 대한 시뮬레이션기법 (Simulation Method on the Protection Effects of Voltage-Limiting Type SPDs Associated with the Protective Distance)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a method of simulating the protection effects of surge protective devices(SPDs) depending on the protective distance and types of input impedance of load to be protected. In order to analyze the protective performances of voltage-limiting type SPDs associated with the reflection and oscillation phenomena, the terminal voltage across load being protected and the residual voltage of SPDs were simulated by using EMTP model as functions of the protective distance and types of input impedance of loads. As a consequence, SPDs should be installed by taking into account the protective distance and input impedance of loads to achieve reliable protection of electrical and electronic equipment from lightning and switching surges. It is expected that the simulation method proposed in this paper could be practically used in design for installing SPDs in low-voltage distribution systems.

보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰 (Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load)

  • 이복희;김유하;안창환
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

철도신호설비용 서지보호기에 대한 규격 검토 (The Review of Specification for SPDs used in Railway Signalling Equipment)

  • 이태훈;박기범;전용주;류영태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.596-602
    • /
    • 2008
  • Recently, there are increasing social needs for safe operation of trains and comforting for passengers. But lightning surges are responsible for serious disturbances such as damage, permanent degradation or temporary erratic operation of sensitive electronics circuits and systems. The purpose of this paper is to identify the requirements for Surge Protective Devices(SPDs) used in protecting railway signalling system. In this paper, we describes tests and requirements which establish methods for testing SPDs and determining their performance.

  • PDF

내장 순시 트립장치를 이용한 MOV의 열폭주 보호와 SPD의 안전성 개선 (Protection of MOV Thermal Runaway and Safety Improvement of SPD using Built-in Instantaneous Trip Device)

  • 김주철;전주술;기채옥;최경래;이상중
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • SPDs are increasingly being used against lightning and switching surge according to the applicable revised standard and equipotential grounding system. SPDs are equipped usually with a MOV voltage regulating element. The MOV, however, always is exposed to the danger of thermal runaway resulting from inrushing temporary overvoltage and deterioration. In this paper, the authors made two prototype SPDs built-in Instantaneous trip device and analyzed their limiting voltage through test of the MOV breakdown. As the result of the analysis, the SPDs built-in Instantaneous trip device was proven to be effective for protecting MOV against thermal runaway and Instantaneous trip device react for limiting voltage is considered that is applicable to SPD.