• Title/Summary/Keyword: SNR control

Search Result 190, Processing Time 0.024 seconds

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

Active noise control algorithm based on noise frequency estimation (소음 주파수 추정 기법을 이용한 능동소음제어 알고리즘)

  • 김선민;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.321-324
    • /
    • 1997
  • In this paper, Active Noise Control(ANC) algorithm is proposed based on the estimated frequency estimator of the reference signal. The conventional feedforward ANC algorithms should measure the reference and use it to calculate the gradient of the squared error and filter coefficients. For ANC systems applied to aircrafts and passenger ships, engines from which reference signal is usually measured is so far from seats where main part of controller is placed that the scheme might be difficult to implement or very costly. Feedback ANC algorithm which doesn't need to measure the reference uses the error signal to update the filter and is sensitive to unexpected transient noise like a sneeze, clapping of hands and so on The proposed algorithm estimates frequencies of the desired signal in real time using adaptive notch filter. New frequency estimation algorithm is proposed with the improved convergence rate, threshold SNR and computational simplicity. Reference is not measured but created with the estimated frequencies. It has strong similarity to the conventional feedback control because reference is made from error signal. Enhanced error signal is used to update the controller for better performance under the measurement noise and impact noise. The proposed ANC algorithm is compared with the conventional feedback control.

  • PDF

Wearable Band Sensor for Posture Recognition towards Prosthetic Control (의수 제어용 동작 인식을 위한 웨어러블 밴드 센서)

  • Lee, Seulah;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.265-271
    • /
    • 2018
  • The recent prosthetic technologies pursue to control multi-DOFs (degrees-of-freedom) hand and wrist. However, challenges such as high cost, wear-ability, and motion intent recognition for feedback control still remain for the use in daily living activities. The paper proposes a multi-channel knit band sensor to worn easily for surface EMG-based prosthetic control. The knitted electrodes were fabricated with conductive yarn, and the band except the electrodes are knitted using non-conductive yarn which has moisture wicking property. Two types of the knit bands are fabricated such as sixteen-electrodes for eight-channels and thirty-two electrodes for sixteen-channels. In order to substantiate the performance of the biopotential signal acquisition, several experiments are conducted. Signal to noise ratio (SNR) value of the knit band sensor was 18.48 dB. According to various forearm motions including hand and wrist, sixteen-channels EMG signals could be clearly distinguishable. In addition, the pattern recognition performance to control myoelectric prosthesis was verified in that overall classification accuracy of the RMS (root mean squares) filtered EMG signals (97.84%) was higher than that of the raw EMG signals (87.06%).

Evaluation of Radiation Dose and Image Quality Between Manual and Automatic Exposure Control Mode According to Body Mass Index in Cardiac CT (체질량지수에 따른 심장 CT검사의 수동노출조절 방법과 자동노출조절 방법의 방사선량 및 화질 평가)

  • Kim, Hyeong-Jin;Moon, Il-Bong;Han, Jae-Bok;Choi, Nam-Gil;Jang, Seong-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.290-299
    • /
    • 2013
  • This study included 198 patients who underwent prospectively electrocardiogram-triggered high-pitch spiral mode(FLASH mode) in cardiac CT for health check: 123 patients who underwent manual exposure control(Group A) and 75 patients who underwent automatic exposure control(Group B). Patients were classified according to BMI grades: Grade 1, Grade 2, Grade 3, Grade 4. Radiation dose, objective and subjective image quality between two groups were compared. In Group B, tube voltage were significantly decreased in all BMI grades. Both $CTDI_{vol}$ and effective dose were significantly reduced in the BMI Grade 1, 3, and 4 whereas they were slightly reduced in the Grade 2(p>0.05), SNR was significantly decreased in the Grade 1 and increased in the Grade 3(p<0.05), but there was no significant difference in the Grade 2, 4 between the two groups(p>0.05). CNR was significantly decreased in the Grade 1(p<0.05), and there was no significant difference in the Grade 2, 3, 4 between the two groups(p>0.05). The subjective image quality showed no significant difference in all BMI Grades between the two groups(p>0.05). Automatic exposure control can lead to a significant reduction of radiation exposure dose without degradation of subjective image quality.

Adaptive Rate Control Scheme in Hybrid ARQ System with Truncated Power Control (절단 전력 제어를 사용하는 하이브리드 ARQ 시스템에서의 적응 부호율 제어 기법)

  • 양우석;김수영
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.121-126
    • /
    • 2001
  • 본 논문에서는 절단 전력 제어를 사용하는 위성통신 시스템에서 부호율을 채널 상황에 따라 적응시켜 최대의 전송 효율을 얻는 하이브리드 ARQ 타입1 부호율 제어 기법을 제안한다. 제안된 기법의 성능을 분석하기 위하여 먼저 하이브리드 ARQ 타입 1 시스템에서 부호율을 채널 상황에 따라 적응적으로 제어했을 때의 전송 효율과 패킷 오율을 유도한다. 또한, 유도된 패킷 오율식으로부터 절단 전력 제어에서 필요한 목적 수신 SNR값을 사용되는 각 부호율에 대해 구하고, 전송 효율을 최대화하는 최적의 부호율 제어변수를 효율적으로 구할 수 있는 방식을 제안한다. 전송효율 측면에서 분석한 결과 제안된 방법이 기존의 방식에 비하여 우수한 성능을 보여줄 수 있음을 확인하였다.

  • PDF

LQG controller design for tracking servo control of holographic data storage system (홀로그래픽 정보저장 장치의 트래킹 서보 제어를 위한 LQG 제어기 설계)

  • Lee, Yong-Hui;Lee, Sang-Hun;KIm, Jang-Hyeon;Yang, Hyeon-Seok;Park, Yeong-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1280-1283
    • /
    • 2007
  • 본 연구는 홀로그래픽 정보저장기기에서 트래킹 서보 제어를 통해 원하는 데이터를 정확하게 기록 및 재생하기 위한 LQG 제어기를 제안하고 검증하는 것을 목적으로 한다. 서보광이라는 추가적인 광을 사용할 것을 제안하여, 서보광과 참조광 간의 간섭에 의해 기록매체에 서보 신호를 얻을 수 있게 하는 홀로그램을 형성한다. 기록 및 재생과정에서 신호광이 기록, 재생됨과 동시에 서보광에 의한 서보 신호가 재생되고, 그 신호의 경로에 설치된 포토 다이오드로부터 디스크 형태에서 발생 할 수 있는 외란을 감지하게 된다. 감지된 외란 신호인 트래킹 에러 신호를 통해 참조광이 디스크의 정확한 위치에 조사되게 하기 위해 평판유리 액츄에이터를 사용한다. 이와 같은 서보 제어를 수행했을 경우 데이터 페이지가 정확하게 재생되며 SNR 과 BER 이 개선되는 것을 확인할 수 있다.

  • PDF

Elimination of Idle Tones by a 2-Bit Adaptive Sigma-Delta Modulation System

  • Prosalentis, Evangelos;Tombras, George S.
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.393-398
    • /
    • 2009
  • The operation of a first-order 2-bit adaptive sigma-delta modulation system is described and discussed in this paper. The system operation is based on the combination of both "memory" and "look-ahead" estimation in the employed step-size adaptation algorithm of the basic quantizer. In comparison to simple systems and other adaptive sigma-delta systems, computer simulation results show that these features of the described system are responsible for the high SNR values and the extended dynamic range achieved for AC signals as well as the noise power reduction of almost 10 dB and the complete elimination of the idle tones for DC signals. However, such an advantageous performance requires the least possible multiplicative error accumulation, and this cannot be achieved without analog circuits of the highest possible accuracy.

Time-Delay Estimation using Wavelet Theory and Higher-Order Statistics (웨이블릿 이론과 고차통계 처리기법을 이용한 시간지연 추정)

  • 차용철;김용남;정지현;남상원
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.5
    • /
    • pp.630-635
    • /
    • 1998
  • The objective of this paper is to propose a new efficient technique for the estimation of time-delay parameters using wavelet theory and third-order cumulants, yielding good performance even in the case of low SNR. In particular, band-limited non-Gaussian signals with non-zero skewness and spatially correlated Gaussian noises are considered here. The approach is based on the fact that the effects of spatially correlated Gaussian noises on time-delay estimation can be reduced by using the projection sequences (based on the redundant wavelet decomposition) of given measurements in the higher-order cumulant domain. Finally, the performance of the proposed approach is demonstrated using simulations.

  • PDF

The Computation Reduction Algorithm Independent of the Language for CELP Vocoders (각국 언어 특성에 독립적인 CELP 계열 보코더에서의 계산량 단축 알고리즘)

  • 민소연;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2451-2454
    • /
    • 2003
  • In this paper, we propose the computation reduction methods of LSP(Line spectrum pairs) transformation that is mainly used in CELP vocoders. In order to decrease the computational time in real root method the characteristic of four proposed algorithms is as the following. First, scheme to reduce the LSP transformation time uses met scale. Developed the second scheme is the control of searching order by the distribution characteristic of LSP parameters. Third, scheme to reduce the LSP transformation time uses voice characteristics. Developed the fourth scheme is the control of searching interval and order by the distribution characteristic of LSP parameters. As a result of searching time, computational amount, transformed LSP parameters, SNR, MOS test, waveform of synthesized speech, speech, spectrogram analysis, searching time reduced about 37.5%, 46.21%, 46.3%, 51.29% in average, computational amount is reduced about 44.76%, 49.44%, 47.03%, 57.40%. But the transformed LSP parameters of the proposed methods were the same as those of real root method.

  • PDF