Mechanical properties of sheet molding compounds (SMC) with different size and contents of ground calcium carbonate (중질 탄산칼슘의 입자크기 및 첨가량 변화에 따라 제조된 시트몰딩 컴파운드(SMC)의 기계적 특징)

  • Lee, Yoonjoo;Koh, Kwang-Woon;Kwon, Woo-Teck;Kim, Younghee;Shin, Dong-Geun
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.84-91
    • /
    • 2017
  • Fiber reinforced plastic (FRP) is a typical plastic composite which is fabricated using fiber reinforcement with resin to represent the high strength properties. The mechanical properties of FRP should be determined by a fibrous material, and the studies about the role of fiber as a reinforcement has been an interested subject, whereas a study along the effect of filler is not so big. However, the filler effect must be considered on the properties of the composite, because the filler influence on the plastic or resin compound which reacts as a matrix material of the composite. Thus, in this work, we studied the filler effect with size and content using $3-6{\mu}m$ of ground calcium carbonate. The specimen was prepared by sheet molding compound (SMC) method, and the mechanical properties were compared with bending strength and tensile strength. As a result, it was confirmed that the size and contents of calcium carbonate affected the strength of composites, and the condition of $2.8{\mu}m$ which was the smallest size condition showed the highest strength.

Installation and Safety Evaluation of Tracking-type Floating PV Generation Structure (추적식 수상 태양광발전 구조물의 시공 및 안전성 평가)

  • Jang, Min-Jun;Kim, Sun-Hee;Lee, Young-Geun;Woo, Sang-Byock;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Pultruded glass fiber reinforced polymeric plastic (PFRP) and FRP member manufactured by sheet molding compound (SMC) have superior mechanical and physical properties compared with those of conventional structural materials. Since FRP has an excellent corrosion-resistance and high specific strength and stiffness, the FRP material may be highly appreciated for the development of floating-type photovoltaic (PV) power generation system. In this paper, advanced floating PV generation system made of PFRP and SMC is designed. In the design, it includes tracking solar altitude by tilting photovoltaic arrays and tracking solar azimuth by spinning structures. Moreover, the results of the finite element analysis (FEA) are presented to confirm stability of entire structure under the external loads. Additionally, installation procedure and mooring systems in the Hap-Cheon Dam are discussed and the measurement of strain under the actual circumstances is conducted for assuring stability of actually installed structures. Finally, by comparison with allowable stress, appropriate safety of structure is confirmed to operate the system.

A Study on the Preparation and Mechanical Properties of Hybrid Composites Reinforced Waste FRP and Urethane Foam (폐 FRP/Urethane Foam 충진 혼성복합재의 제조 및 기계적 물성에 관한 연구)

  • 황택성;신경섭;박진원
    • Polymer(Korea)
    • /
    • v.24 no.4
    • /
    • pp.564-570
    • /
    • 2000
  • The waste FRP occured in the fabrication of SMC (sheet molding compound) bathtubs and the waste polyurethane foam occured in electronic manufacture and waste insulator were applied as a soundproof and light weight pannel in the waste FRP unsaturated polyester matrix resin composites to recycle. The effect of filler contents on the mechanical properties and interfacial phenomena of the filler and matrix on the composites was evaluated. The tensile strength of composites reached its maximum value of 82.34 MPa when the filler content was 70 wt%, and the more content of reinforcement is increased, the more tensile modulus was decreased. The flexural strength and modulus of composites, reinforced 70 wt% with filler content, were dominant compared to the other samples to 72.5 MPa, 958.4 MPa respectively. When composite of reinforced 70 wt% with filler content, it was confirmed that pull out phenomena and cracks did not occur in the interface of reinforcement and matrix resin through the SEM observation. Also, waste FRP and urethane foam were dispersed well into matrix resin as filler.

  • PDF

Development of Element Technique for the Floating PV Generation Structure Using FRP (FRP를 활용한 수상 부유식 태양광발전 구조물의 요소기술 개발)

  • Seo, Su-Hong;Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.27 no.3
    • /
    • pp.103-108
    • /
    • 2014
  • Fiber reinforced polymer plastic (FRP) structural members are recently available in construction industries due to various material properties such as high specific strength and stiffness, light-weight, and corrosionresistance. The floating PV generation structure can also be an illustration for applying FRP in construction applications. The floating PV generation structure has been recently issued as a representative item for the low carbon and green growth campaign and many related studies have been conducted for the structural safety and commercial viability. Moreover, the floating PV generation structures for the commercial purpose have been constructed. In this paper, the investigation and development processes of elements for the floating PV generation structure are presented during commercialization.

Performance Enhancement of Floating PV Generation Structure Using FRP (FRP를 활용한 부유식 태양광발전 구조시스템의 성능 향상)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Hwang, Seong-Tae;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • In this study, we suggest the new floating PV generation structure which is improved the structural and economical efficiency compared with the system developed in the previous research. Pultruded FRP has superior physical and chemical material properties compared with those of conventional structural materials. Especially, pultruded FRP has an excellent corrosion-resistance, light-weight, and it also has high specific strength and stiffness which are highly appreciated for the design and fabrication of floating PV generation structure under harsh environmental condition. In this study, structural analysis using the finite element method has been performed to investigate the safety of new floating PV generation structure and newly applied structural members.

Effect of Coupling Agent(3-methylacryloxyviny1silane) on the Mechanical Properties of wasfeaste FRP/Unsaturated Polyester Composites (폐 FRP/불포화 폴리에스테르 수지 복합재의 기계적 물성에 미치는 실란계 커플링제 (3-methylacryloxyvinyl silane) 영향)

  • Hwang, Taek-Seong;Choe, Don-Muk;Choe, Jang-Rak;Im, Jeong-Hun;Park, Jeong-Gi
    • Korean Journal of Materials Research
    • /
    • v.8 no.1
    • /
    • pp.13-18
    • /
    • 1998
  • SMC(Sheet molding compound)욕조 생산시 발생하는 폐 FRP를 보강재로서 재활용하기 위하여 불포화 폴리에스테르 매트릭스 수지에 보강하고 보강재와 매트릭스 수지의 계면 결합력을 증진시키기 위하여 보강재를 실란계 커플링제[3-methylacryloxyviny1 silane (MAOS)]로 전 처리하여 복합재를 제조하고 기계적 물성 및 계면현사에 대하여 관찰하였다. 보강률이 20wt%인 복합재의 굴곡강도 및 굴곡탄성률이 각 각 110MPa, 8.0GPa로 가장 우수하였으며 커플링제(MAOS)의 노동가 0.50wt%인 복합재의 굴곡강도 및 굴곡탄성률은 약 10%정도 향상되어 각 각 120MPa, 9.2GPa을 나타내었다. 또한 주사전자현미경 관찰 결과 보강재를 커플링제(MAOS)로 처리한 복합재의 보강재와 매트릭스 수지는 물리, 화학적을 잘 결합하여 보강재와 매트릭스 수지의 계면에서 pull out현상이 확인되지 않았으며 크랙도 발생하지 않았다.

  • PDF

A Study on the Water Quality for Efficient Management in the Water Tanks (저수조의 효율적 관리를 위한 수질실태에 관한 연구)

  • Park, Hyun-Geoun;Ryu, Seung-Chul;Jun, Soo-Im
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1339-1347
    • /
    • 2009
  • This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.