• Title/Summary/Keyword: SI technique

Search Result 1,432, Processing Time 0.024 seconds

Tree-dimensional FE Analysis of Acoustic Emission of Fiber Breakage using Explicit Time Integration Method (외연적 시간적분법을 이용한 복합재료 섬유 파단 시 음향방출의 3차원 유한요소 해석)

  • Paik, Seung-Hoon;Park, Si-Hyong;Kim, Seung-Jo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.172-175
    • /
    • 2005
  • The numerical simulation is performed for the acoustic emission and the wave propagation due to fiber breakage in single fiber composite plates by the finite element transient analysis. The acoustic emission and the following wave motions from a fiber breakage under a static loading is simulated to investigate the applicability of the explicit finite element method and the equivalent volume force model as a simulation tool of wave propagation and a modeling technique of an acoustic emission. For such a simple case of the damage event under static loading, various parameters affecting the wave motion are investigated for reliable simulations of the impact damage event. The high velocity and the small wave length of the acoustic emission require a refined analysis with dense distribution of the finite element and a small time step. In order to fulfill the requirement for capturing the exact wave propagation and to cover the 3-D simulation, we utilize the parallel FE transient analysis code and the parallel computing technology.

  • PDF

Direct UV laser projection ablation to engrave 6㎛-wide patterns in a buildup film (빌드업 필름의 선폭 6㎛급 패턴 가공을 위한 직접식 UV 레이저 프로젝션 애블레이션)

  • Sohn, Hyonkee;Park, Jong-Sig;Jeong, Jeong-Su;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.17 no.3
    • /
    • pp.19-23
    • /
    • 2014
  • To directly engrave circuit-line patterns as wide as $6{\mu}m$ in a buildup film to be used as an IC substrate, we applied a projection ablation technique in which an 8 inch dielectric ($ZrO_2/SiO_2$) mask, a DPSS 355nm laser instead of an excimer laser, a ${\pi}$-shaper and a galvo scanner are used. With the ${\pi}$-shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam. The galvo scanner before the $f-{\theta}$ lens moves the flat-top beam ($115{\mu}m{\times}105{\mu}m$) across the 8 inch dielectric mask whose patterned area is $120mm{\times}120mm$. Based on the results of the previous research by the authors, the projection ratio was set at 3:1. Experiments showed that the average width and depth of the engraved patterns are $5.41{\mu}m$ and $7.30{\mu}m$, respectively.

  • PDF

Shape Optimization for Prolonging Fatigue Life of a Structure (구조물의 피로수명 향상을 위한 형상 최적화)

  • Han, Seok-Yeong;Song, Si-Yeop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1512-1519
    • /
    • 2002
  • Most of mechanical failures are caused by repeated loadings and therefore they are strongly related to fatigue. To avoid the failures caused by fatigue, determination of an optimal shape of a structure is one of the very important factors in the initial design stage. Shape optimization fer two types of specimens, which are very typical ones in opening mode in fracture mechanics, was accomplished by the linear elastic fracture mechanics and the growth-strain method in this study. Also shape optimization for a cantilever beam in mixed mode was carried out by the same techniques. The linear elastic fracture mechanics was used to estimate stress intensity factors and fatigue lives. And the growth-strain method was used to optimize the shape of the initial shape of the specimens. From the results of the shape optimization, it was found that shapes of two types of specimens and a cantilever beam optimized by the growth-strain method prolong their fatigue lives significantly. Therefore, it was verified that the growth-strain method is an appropriate technique for shape optimization of a structure having a crack.

A Case of Design and Field Construction on the Removable Post-tensioned Soil Nailing System (제거식 포스트텐션 쏘일네일의 설계 및 시공사례)

  • Park, Si-Sam;Park, Joo-Suck;Kim, Eung-Soo;Yoon, Myung-June;Park, Ji-Woong;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1081-1086
    • /
    • 2010
  • The general soil nailing support system may result in excessive deformations particularly in an excavation zone of the existing weak subsoils. Pretensioning the soil nails then, could play important roles to reduce deformations mainly in part of the nailed-soil excavation system as well as to improve local stability. Morever, soil nails are installed underneath roads, underground structures, and subway structures, thereby resulting in difficulties in nail remval after completion of temporary soil nailed walls. Hence, to date, in order to solve the technical difficulties and avoid legal issues related to the construction of soil nails underneath the surrounding areas and structures, the removable soil nailing system has been developed and used. But, Therefore, a new soil nailing technique called Removable Post-tensioned Soil Nailing(RPTN) system has been developed in the current study. In this study, an investigation of the RPTN system has been conducted by carrying out field measurement. Hence, the RPTN system can reduce ground displacement and enhance stability of the soil nailed walls.

  • PDF

The Strength Properties of Concrete Used Stone Powder Sludge as Siliceous Material (실리카질 재료로서 석분 슬러지를 사용한 콘크리트의 강도 특성)

  • Jeong Ji Yong;Choi Sun Mi;Kawg Eun Gu;Choi Se Jin;Lee Seong Yeon;Kim Jin Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.85-88
    • /
    • 2005
  • The stone powder sludge occurred at aggregate production process is classified the specified waste, so it is disposed by appropriate method. But the problems of the shortage of the disposal-site, the environment pollution, and the increase of disposal cost can be occurred in handling process, therefore the stone powder sludge is required the development of recycling technique. The stone powder sludge includes SiO2 of about $63\%$. This characteristic is important at the production of hardened specimens under condition of hydro-thermal reaction. In this study, we investigated the strength properties of concrete used stone powder sludge as siliceous material. The test results under condition of hydro-thermal reaction shows the two main facts. The first, the stone powder sludge is affected to fluidity because the surface of the stone powder sludge has characteristics of flakily and angularity. The second, weight content of the stone powder sludge, is not effective factor to the properties of strength.

  • PDF

Hemodynamic Changes on Stellate Ganglion Block Measured by Bioimpedance Method (성상신경절 차단시 Bioimpedance를 이용한 혈액학적 변화의 측정)

  • Kwak, Dong-Myeon;Kim, Si-Oh;Hong, Jung-Gil;Park, Jin-Woong
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.336-339
    • /
    • 1996
  • Stellate ganglion block which usually practiced in pain clinics may combined with hemodynamic changes because it blocks sympathetic nerve chains. We measured the hemodynamic changes with NCCOM3-$R7^{(R)}$ (BOMED, U.S.A.) which applicated bioimpedance method in twenty-two patients. Mean arterial pressure, heart rate, cardiac output, ejection fraction and left ventricle end diastolic volume (LEDV) were measured before stellate ganglion block (control), 1, 3, 5, 10 and 20 minutes after stellate ganglion block with 8 ml of 0.25% bupivacaine. The results were as follows: Mean arterial pressure decreased significantly (p<0.05) in 10, 20 minutes after stellate ganglion block comparing to control, but not clinically significant. Heart rate, cardiac output, ejection fraction and LVEDV showed no significant change compared to control value. These results showed that stellate ganglion block is a safe technique without significant hemodynamic changes.

  • PDF

Enhanced effect of magnetic anisotropy on patterned Fe-Al-O thin films

  • N.D. Ha;Kim, Hyun-Bin;Park, Bum-Chan;Kim, C.G.;Kim, C.O.
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.239-239
    • /
    • 2003
  • As a result of the recent miniaturization and enhancement in the performance of thin film inductors and thin film transformers, there are increased demands for the thin films with a high magnetic permeability in the high frequency range, a high saturation magnetization, a high electrical resistivity, and a low coercive force. In order to improve high frequency properties, we will investigate anisotropy field by shape and size of pattern. The Fe-Al-O thin films of 16mm diameter and 1$\mu\textrm{m}$ thickness were deposited on Si wafer, using RE magnetron reactive sputtering technique with the mixture of argon and oxygen gases. The fabricating conditions are obtained in the working partial pressure of 2m Torr, O$_2$ partial Pressure of 5%, Input power of 400w, and Al pellets on an Fe disk with purity of 99.9%. For continuous thin film is the 4Ms of 19.4kG, H$\sub$c/ of 0.6Oe, H$\sub$k/ of 6.0Oe and effective permeability of 2500 up to 100MHz. In this work, we expect to enhanced effect of magnetic anisotropy on patterned of Fe-Al-O thin films.

  • PDF

An Enhanced Secure Health Data Transmission Protocol using Key Insulation in Remote Healthcare Monitoring System (원격 헬스케어 모니터링 시스템에서 키 격리기법을 이용한 개선된 건강정보 전송 보안 프로토콜)

  • Noh, Si-Wan;Park, Youngho;Rhee, Kyung-Hyune
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.12
    • /
    • pp.1981-1991
    • /
    • 2016
  • In recent, the advancement of wearable devices and wireless body area networking technologies motivate researchers to pay attention to remote healthcare system for monitoring patients health and disease progression effectively. However, in order to implement a practical remote healthcare system, we must consider the security and privacy of patient's personal health information transmitted to healthcare servers through the network. Hence, in this paper, we propose a secure health data transmission protocol in remote healthcare monitoring system to protect patient's health information and prevent privacy from eavesdropping on the network. To achieve our security goals, we design an efficient secure protocol based on the identity-based cryptography with key evolution technique, and then confirm the superiority and the efficiency of the proposed protocol as compared with the existing protocol of Yang et al.

A VoIP System for Secure Support in Next Generation Networks based on SIP (차세대 네트워크환경에서의 보안성 지원을 위한 SIP 기반 VoIP 시스템)

  • Sung, Kyung;Kim, Seok-Hun;Park, Gil-Ha
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2321-2328
    • /
    • 2006
  • Today, SIP standard (The signalling protocol for the Internet phone service) raises to be the standard technique because the expandability is high and complexity is low. It is widely investigated and actively advocated to use Si81a1 ring protocol for SIP in VoIP service. SIP service can be applied even outside the Internet phone service; instance messaging and various multimedia technology are just an example. This paper proposed an embodiment proxy server for rambling support to use JAIN SIP API. It provides standard interface for testing the Proxy server for SIP and embodiment of user agent that transfer instant massaging and voice communication.

Performance Test and Evaluations of a MEMS Microphone for the Hearing Impaired

  • Kwak, Jun-Hyuk;Kang, Hanmi;Lee, YoungHwa;Jung, Youngdo;Kim, Jin-Hwan;Hur, Shin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.326-331
    • /
    • 2014
  • In this study, a MEMS microphone that uses $Si_3N_4$ as the vibration membrane was produced for application as an auditory device using a sound visualization technique (sound visualization) for the hearing impaired. Two sheets of 6-inch silicon wafer were each fabricated into a vibration membrane and back plate, after which, wafer bonding was performed. A certain amount of charge was created between the bonded vibration membrane and the back plate electrodes, and a MEMS microphone that functioned through the capacitive method that uses change in such charge was fabricated. In order to evaluate the characteristics of the prepared MEMS microphone, the frequency flatness, frequency response, properties of phase between samples, and directivity according to the direction of sound source were analyzed. The MEMS microphone showed excellent flatness per frequency in the audio frequency (100 Hz-10 kHz) and a high response of at least -42 dB (sound pressure level). Further, a stable differential phase between the samples of within -3 dB was observed between 100 Hz-6 kHz. In particular, excellent omnidirectional properties were demonstrated in the frequency range of 125 Hz-4 kHz.