• 제목/요약/키워드: SHEAR STRENGTH

검색결과 5,534건 처리시간 0.03초

모래 지반 내에 형성된 공극이 전단강도에 미치는 영향 (Effect of Void Formation on Shear Strength of Sand)

  • 최현석;박성식;김창우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.577-583
    • /
    • 2010
  • In this study, the effect of void formation resulting from gas hydrate dissociation or loss of some particles within soil structure on the strength of soil is examined. Beag-ma river sands with uniform gradation were used to simulate a gas hydrate bearing or washable soil structure. Empty capsules for medicine are used to mimic large voids, which are bigger than soil particle. Beag-ma river sand was miced with 8% cement ratio and 14% water content and compacted into a shear box. The number and direction embedded into a specimen. After 4 hours curing, a series of direct shear test is performed on the capsule embedded cemented sands. Shear strength of cemented sands with capsules depends on the volume and direction. The volume and direction formed by voids are most important factors in strength. A shear strength of a specimen with large voids decreases up to 39% of a specimen without void. The results of this study can be used to predict the strength degradation of gas hydrate bearing sediments after dissociation and loss of fine particles within soil structure.

  • PDF

고강도 전단보강 철근을 사용한 철근콘크리트 보의 거동평가 (Structural Behavior of Reinforced Concrete Beams using High Strength Shear Reinforcement)

  • 최임준;박종욱;황현복;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.3-4
    • /
    • 2009
  • 본 연구에서는 전단보강 철근 및 콘크리트 강도에 따른 철근콘크리트 보의 구조적 거동 파악과 현재 사용되고 있는 전단보강 철근의 강도 제한을 평가하였다. 현행 설계기준에서, 실제 설계되는 콘크리트구조물에 적용되는 전단보강 철근은 항복강도가 400 MPa 이하이어야 한다고 규정하고 있는데 이것은 항복강도가 너무 큰 철근을 사용하는 경우, 구조물에 과도한 균열이나 처짐이 발생할 수 있고, 연성능력, 피로 저항성능, 전단 및 비틀림 저항성능, 정착 성능, 내진 저항성능 등에 대하여 검증 되지 않았기 때문이다. 따라서 본 연구를 통해 고강도의 전단보강 철근이 콘크리트 구조물에 적용되었을 때 나타나는 철근콘크리트 보의 거동 및 구조적 성능을 평가하였다.

  • PDF

Potential of adaptive neuro fuzzy inference system for evaluating the factors affecting steel-concrete composite beam's shear strength

  • Safa, M.;Shariati, M.;Ibrahim, Z.;Toghroli, A.;Baharom, Shahrizan Bin;Nor, Norazman M.;Petkovic, Dalibor
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.679-688
    • /
    • 2016
  • Structural design of a composite beam is influenced by two main factors, strength and ductility. For the design to be effective for a composite beam, say an RC slab and a steel I beam, the shear strength of the composite beam and ductility have to carefully estimate with the help of displacements between the two members. In this investigation the shear strengths of steel-concrete composite beams was analyzed based on the respective variable parameters. The methodology used by ANFIS (Adaptive Neuro Fuzzy Inference System) has been adopted for this purpose. The detection of the predominant factors affecting the shear strength steel-concrete composite beam was achieved by use of ANFIS process for variable selection. The results show that concrete compression strength has the highest influence on the shear strength capacity of composite beam.

자가부식형 상아질 접착제와 상아질과의 전단결합강도 비교 (Comparison of the shear bond strength of self-etching dentin bonding agents to dentin)

  • 노수정;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.141-150
    • /
    • 2007
  • The purpose of this study was to ascertain the bonding durability of self-etching dentin bonding agents to dentin by means of shear bonding strength. Several acid-etching dentin bonding system (ESPE Z100) and self-etching dentin bonding systems (DEN-FIL, GRADIA DIRET) were used. The occlusion surface of human molars were ground flat to expose dentin and treated with the etch bonding system according to manufactures instruction and followed by composite resin application. After 24hours of storage at 37$^{\circ}C$, the shear bonding strength of the specimens was measured in a universal testing machine with a 1mm/min crosshead speed. An one-way analysis of variance and the scheffe test were performed to identify significant differences (p<0.05). The bonded interfacial surfaces and treated dentin surfaces were examined using a SEM. Through the analysis of shear bond strength data and micro-structures of dentin-resin interfaces, following results are obtained. In dentin group, the shear bond strength of DEN-FIL showed statistical superiority in comparison to the other groups and followed by ESPE Z100 and GRADIA DIRECT (p<0.05).

  • PDF

열시효 처리된 무연 솔더 볼 연결부의 충격 전단강도 평가 (Evaluation of the Impact Shear Strength of Thermal Aged Lead-Free Solder Ball Joints)

  • 정진성;김호경
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.7-11
    • /
    • 2015
  • The present study investigates the impact shear strength of thermal aged Sn-3Ag-0.5Cu lead-free solder joints at impact speeds ranging from 0.5 m/s to 2.5 m/s. The specimens were thermal aged for 24, 100, 250 and 1000 hours at $100^{\circ}C$. The experimental results demonstrate that the shear strength of the solder joint decreases with an increase in the load speed and aging time. The shear strength of the solder joint aged averagely decreased by 43% with an increase in the strain rate. For the as-reflowed specimens, the mode II stress intensity factor ($K_{II}$) of interfacial IMC between Sn-3.0Ag-0.5Cu and a copper substrate also was found to decrease from $1.63MPa.m^{0.5}$ to $0.97MPa.m^{0.5}$ in the speed range tested here. The degradations in the shear strength and fracture toughness of the aged solder joints are mainly caused by the growth of IMC layers at the solder/substrate interface.

금속-도재관용 Ni-Cr합금의 조성변화와 소성단계에 따른 전단결합강도 (Observation of Shear Bonding Strength by Compositional Change and Firing Steps of the Ni-Cr Alloy for Porcelain Fused Metal Crown)

  • 조용완;홍민호;김원영;최성민;정인성
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.353-358
    • /
    • 2013
  • Purpose: This study was observation shear bonding strength by compositional change and firing step of a Ni-Cr alloy for porcelain fused metal crown. The aim of study was to suggest the material for firing step of Ni71-Cr14 alloy to development of alloy for porcelain fused to metal crown. Methods: The test was on the two kinds of Ni-Cr alloy specimens. The surfaces of two alloys were analyzed by EDX in order to observe oxide characteristic. And the shear test was performed by MTS. Results: The surface property and oxide characteristic analysis of oxide layer, weight percentage of Element O within $Ni_{71}Cr_{14}$ alloy measured 23.32wt%, and $Ni_{59}Cr_{24}$ alloy was measured 23.03wt%. And the maximum shear bonding strength was measured 58.02MPa between $Ni_{59}Cr_{24}$ alloy and vintage halo(H4 group). Conclusion: The surface property and oxide characteristic three kind of Ni-Cr alloy was similar. and shear bonding strength showed the highest bonding strength in H4 specimens.

Experimental shear strength evaluation of perfobond shear connector with various hole shapes

  • Zheng, Shuangjie;Zhao, Chen;Liu, Yuqing
    • Structural Engineering and Mechanics
    • /
    • 제67권2호
    • /
    • pp.131-142
    • /
    • 2018
  • The perfobond connector, composed of a steel plate with a number of holes, serves as a certain type of shear connector in steel and concrete composite structures. Depending on limits in hole distances and rib heights, various hole shapes including circular-hole and long-hole are alternatives for perfobond connectors. This study presented the results of tests performed on 72 push-out specimens with perfobond connectors. The purpose was to evaluate the shear strength of perfobond connectors with circular-hole and long-hole. The effects of various parameters were investigated, including the hole diameter, the hole length, the hole height, the concrete strength, the existence, diameter and strength of rebar in the hole, the thickness, height and distance of perfobond ribs, and the thickness of concrete slabs. On the basis of 132 push-out test results in references and in this study, an analytical model was proposed by regression analysis to predict the shear strength of perfobond connectors. The proposed equation agreed reasonably well with the experimental results of perfobond connectors with different hole shapes.

스트립 모델을 이용한 강판 전단패널의 소성 해석 (Plastic Analysis of Steel Plate Shear Panels using Strip Model)

  • 이명호;문태섭
    • 한국강구조학회 논문집
    • /
    • 제18권1호
    • /
    • pp.71-80
    • /
    • 2006
  • 강판 전단패널의 거동이 일반연강 (S400) 을 이용한 실험 및 해석으로 고찰되었다. 강판 전단패널은 작은 하중에서 좌굴을 하지만, 패널의 전단극한강도는 인장력 작용에 의한 강판 전단패널의 좌굴후 강도에 의해 좌우된다. 그러나, 설계상에서 강판 전단패널의 성능은 강판 전단패널의 탄성좌굴강도에 국한된다. 캐나다 극한강도 설계 규준 (CAN/CSA-S16.1-94)은 스트립 모델을 이용한 박강판 전단패널의 해석을 위한 절차를 규정하고 있다. 본 논문에서는 실험결과와 스트립모델 해석 결과를 이용하여 강판 전단패널의 구조성능을 평가하였다.

리플로우 조건에 따른 Sn-52In 솔더범프의 전단응력과 전단에너지 비교 (Comparison of Shear Strength and Shear Energy for 48Sn-52In Solder Bumps with Variation of Reflow Conditions)

  • 최재훈;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제12권4호통권37호
    • /
    • pp.351-357
    • /
    • 2005
  • 솔더/UBM 계면반응에 따른 솔더범프의 기계적 신뢰성을 평가하기 위한 방안으로서 Cu UBM 상에서 리플로우한 Sn-52In 솔더범프의 리플로우 조건에 따른 전단응력과 전단에너지의 변화거동을 비교하였다. 리플로우 조건에 따른 전단에너지의 변화거동이 전단강도에 비해 Sn-52In/Cu 계면반응 및 파괴모드의 변화거동과 훨씬 잘 일치하여 솔더/UBM 계면반응에 따른 기계적 신뢰성을 분석하는데 전단에너지가 전단강도보다 훨씬 효과적인 평가 방안임을 알 수 있었다.

  • PDF

강섬유(鋼纖維) 보강(補强)콘크리트보의 전단특성(剪斷特性)에 관한 연구(研究) (A Study on the Shear Properties of Steel Fiber Reinforced Concrete Beams)

  • 문제길;홍익표
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-12
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 강섬유보강콘크리트 보의 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 섬유로 보강된 21개의 보를 포함한 총 36개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 섬유혼입율, 전단지간, 인장철근량 등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도 등을 측정하였다. 실험결과로부터 섬유의 혼입량이 많아지고, 콘크리트의 강도가 커질수록, 그리고 전단지간이 짧아질수록 섬유보강콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험결과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험결과를 비교 검토하여 그 상관성을 확인하였다.

  • PDF