• Title/Summary/Keyword: SHEAR STRENGTH

Search Result 5,534, Processing Time 0.031 seconds

Shear Behavior of Slender HSC Beams Reinforced with Stirrups using Headed Bars, High Strength Steels, and CFRP Bars (헤디드 바, 고장력 철근 및 CFRP 바로 전단보강된 세장 고강도콘크리트 보의 전단 거동 평가)

  • Yang, Jun-Mo;Kwon, Ki-Yeon;Choi, Hong-Shik;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.717-726
    • /
    • 2007
  • If conventional reinforcements are used for high-strength concrete (HSC) structures, a large amount of the reinforcement must be required to compensate for the brittleness of HSC and make the best use of HSC. This raises some structural problems such as steel congestion and an increase in self-weight. Therefore, alternative reinforcing materials and methods for HSC structures are needed. In this study, four full-scale beam specimens constructed with HSC (100 MPa) were tested to investigate the effect of the different shear reinforcements on the shear behavior. These four specimens were reinforced for shear stirrups with normal and high strength steels, headed bars, and carbon fiber-reinforced polymer (CFRP) bars, respectively. In addition, steel fibers were added to the HSC in the two of the specimens to observe their beneficial effects. The use of high strength steels resulted in the improvement of the shear capacity since the shear resistance provided by the shear reinforcements and the bond strength were increased. The specimen reinforced with headed bars also showed a superior performance to the conventional steel reinforced specimen due to the considerably high anchorage strength of headed bar. CFRP bars used in this research, however, seemed to be inadequate for shear reinforcement because of the inferior bond capacity. The presence of the steel fibers in concrete led to remarkable improvement in the ductility of the specimens as well as in the overall cracks control capability.

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

Shear bond strength of veneering porcelain to zirconia and metal cores

  • Choi, Bu-Kyung;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.129-135
    • /
    • 2009
  • STATEMENT OF PROBLEM. Zirconia-based restorations have the common technical complication of delamination, or porcelain chipping, from the zirconia core. Thus the shear bond strength between the zirconia core and the veneering porcelain requires investigation in order to facilitate the material's clinical use. PURPOSE. The purpose of this study was to evaluate the bonding strength of the porcelain veneer to the zirconia core and to other various metal alloys (high noble metal alloy and base metal alloy). MATERIAL AND METHODS. 15 rectangular ($4\times4\times9mm$) specimens each of zirconia (Cercon), base metal alloy (Tillite), high noble metal alloy (Degudent H) were fabricated for the shear bond strength test. The veneering porcelain recommended by the manufacturer for each type of material was fired to the core in thickness of 3mm. After firing, the specimens were embedded in the PTFE mold, placed on a mounting jig, and subjected to shear force in a universal testing machine. Load was applied at a crosshead speed of 0.5mm/min until fracture. The average shear strength (MPa) was analyzed with the oneway ANOVA and the Tukey's test ($\alpha$= .05). The fractured specimens were examined using SEM and EDX to determine the failure pattern. RESULTS. The mean shear strength ($\pm\;SD$) in MPa was 25.43 ($\pm\;3.12$) in the zirconia group, 35.87 ($\pm\;4.23$) in the base metal group, 38.00 ($\pm\;5.23$) in the high noble metal group. The ANOVA showed a significant difference among groups, and the Tukey' s test presented a significant difference between the zirconia group and the metal group. Microscopic examination showed that the failure primarily occurred near the interface with the residual veneering porcelain remaining on the core. CONCLUSION. There was a significant difference between the metal ceramic and zirconia ceramic group in shear bond strength. There was no significant difference between the base metal alloy and the high noble metal alloy.

Adhesion between heat-pressed lithium disilicate veneer and zirconia framework: Shear bond strength evaluation (열가압 리튬 디실리케이트 전장도재와 지르코니아 하부구조의 전단결합강도 평가)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.335-341
    • /
    • 2020
  • This study examined the shear bond strength between the zirconia core and pressed lithium disilicate veneering ceramics. The Schmitz-Schulmeyer test method was used to investigate the core-veneer shear bond strength of industrially manufactured zirconia core ceramic (Zirtooth, HASS, Gangneung, Korea) and pressed veneer ceramic (IPS e.max Zirpress, Vita PM9, GC Initial IQ, HASS Rosetta SM) (N=40). Data were statistically analyzed using one-way ANOVA and Tukey's test (a=0.05). The fractured surfaces of the specimens were examined to determine the failure pattern using a digital microscope. The mean ± SD shear bond strength in MPa were 16.69±3.11, 14.21±3.63, 11.17±2.92, and 27.90±5.71 for IPS e.max Zirpress, VITA PM9, GC Initial IQ, and HASS Rosetta SM, respectively. The average shear bond strength was largest for HASS Rosetta SM, followed by IPS e.max Zirpress, Vita PM9, and GC Initial IQ(p<0.05). The digital microscopy examination of the fracture surface showed adhesive and cohesive failure in pressed lithium disilicate veneering ceramics. The use of lithium disilicate veneer ceramic produced a significantly higher shear bond strength.

Comparison of shear bond strength according to porcelain build-up methods (도재 축성 방법에 따른 금속 도재관의 전단결합강도 비교)

  • Lee, Ha-Young;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.112-120
    • /
    • 2014
  • Purpose: This study compared the shear bond strength of heat pressed and feldspathic porcelain to metal. Through thermocycling, the clinical aspect of heat pressed porcelain fused metal was estimated. Materials and Methods: 90 non-precious metal specimens were made ($4{\times}4{\times}8 mm$) and divided to three groups. All spicimens were treated and built-up with the porcelain ($4{\times}4{\times}3 mm$) by 2 different methods according to group: Group I: $Inspiration^{(R)}$, Group II: Ivoclar, IPS $Inline^{(R)}PoM$, Group III: GC Initial IQ-One $Body^{(R)}PoM$. The half of each group's specimens were thermocycled. All specimens' shear bond strength were measured by Instron universal testing machine. Exact measuring point was far 1 mm from porcelain/metal interface to the porcelain side. For the statistical analysis, 2-way ANOVA was used. Results: In no-thermocycling specimens, the shear bond strength showed no statistical significance between each group (P > 0.05). In comparison between nothermocycling and thermocycling specimens in each group, the shear bond strength was decreased according to thermocycling, but there was no statistical significance (P > 0.05). In thermocycling specimens, there was no statistical significance between each group (P > 0.05). Conclusion: In feldspathic porcelain and other two types heat pressed porcelain, there was no statistical difference in the shear bond strength of porcelain to metal. The heat pressed porcelain seems to be clinically useful for the aspect of the shear bond strength.

Investigation of the Shear Bond Strength of Orthodontic Buttons by Light Curing Using an Extended Optic Fiber (광섬유를 이용한 광중합에 따른 교정용 버튼의 전단결합강도에 관한 연구)

  • Yoon, Garam;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan;Choi, Wonseok;Sung, Minah
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.105-114
    • /
    • 2021
  • The objective of this study is to analyze the shear bond strength of orthodontic buttons according to light tip distance and optic fiber diameter when an extended optic fiber was applied to the tip of a curing light unit. In this study, 315 extracted premolar teeth were divided into 3 groups. Orthodontic buttons were attached using no optic fibers (Group I), 3.0 mm diameter optic fibers (Group II), or 5.0 mm diameter optic fibers (Group III). Each group was divided into subgroups A - C (5.0, 10.0, and 15.0 mm light tip distance), respectively. Shear bond strength was then measured while varying the light tip distance. In group I, shear bond strength significantly decreased as the light tip distance increased. When the shear bond strength was evaluated according to the optic fiber diameter, no statistical significance was observed in group of 5.0 mm light tip distance. Compared with group IB, group IIIB showed significantly greater shear bond strength. Compared with group IC, all groups using 3.0 or 5.0 mm diameter optic fibers showed significantly greater shear bond strength. Therefore, when a curing light unit has poor accessibility, optic fibers with a large diameter should be considered.

A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials (3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구)

  • Cho, Sung-Yoon;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.232-243
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the shear bond strength of various 3D printed denture base resins and the conventional denture base resin to various denture relining materials. Materials and Methods: For denture base materials, a heatcured (Vertex RS) and two types of 3D printed DENTCA Denture base II, NextDentTM Base) were used. And 4 types denture relining materials (Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit) with different components were used. It was classified into 12 groups. Adhesion was performed between the resin base and the relining materials in accordance with ISO/TS 11405 standard. The shear bonding strength was measured, and then the adhesion interface was observed with a stereoscopic microscope and a scanning electron microscope. The fracture pattern was investigated through the analysis of the fragment. Results: In the 3D printed denture resin group, the shear bonding strength with relining materials was significantly lower than that of the heat-cured resin group (P < 0.05). The group of polymethyl methacrylate -based relining materials, high shear bonding strength was shown regardless of the type of denture. As for the fracture pattern, adhesive fracture appeared in most groups, and cohesive, mixed fracture appeared in some groups. Conclusion: The polymethyl methacrylate -based denture relining materials showed high shear bonding strength values compared to other denture relining materials. But, for direct methods, it is considered advantageous in terms of shear bonding strength to use a isobutyl methacrylate-based denture relining materials.

A Study on Shear Behavior of High Strength Reinforced Concrete Beams (고강도 철근콘크리트 보의 전단거동에 관한 연구)

  • Kwak, Kae-Hwan;Park, Jong-Gun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.68-79
    • /
    • 1998
  • In the years, the concern about high-strength concrete which is new material has been heightened as a result of active research and development. Recently, as the building structure has been being bigger, higher, longer and more specialized, the demand of material with high-strength concrete for building has been increasing. The demand of high -strength concrete is expected to increase with expansion of usage about the complex concrete structures such as bridge structure as well as nuclear plants, underground structures, hydraulic structures and arctic area sturctures. In this research, silica-fume was used as an admixture in order to get a high-strength concrete. Water/binder ration was limited no more than 18 percent and the amount of unit cement was increased. In this study, a number of trial in concrete mix was carried out to get optimal mix design, and the target slump with $10{\pm}2cm$ was set for in-situ construction. High-strength concrete with cylinder strength of 1,200kgf/$cm^2$ in the 28-days was produced and tested. The static test was carried out to measure the ultimate load, the initial load of flexural and diagonal cracking, crack patterns, fracture modes. The load versus strain and load versus deflection relations were obtained form the static test. The test results were compared with the shear strengths predicted by the equations of ACI code 318-89 and orther researchers. Based on the test results, shear strength equation of reinforced concrete beam using high strength concrete was proposed. Form an evaluation of the results of this experimental investigation, it was concluded that shear strength after diagonal tention cracking diminished with the increase in compressive strength for beams.

  • PDF

An Experimental Study of SL Shear Reinforcement for Reinforced Concrete Flat Plate Slab (철근콘크리트 무량판 슬래브의 일체형 SL(Shear Ladder) 전단보강재에 관한 실험적 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Park, Seung-Hwan;Kim, Shin;Shin, Chan-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.53-56
    • /
    • 2011
  • This study is concerned with the SL shear reinforcement that it can be installed easily in filed as product at the factory and seismic performance can be achieved. The method of study is as follows. first, we researched constructability and economy of existing method. Secondly, we made specimen and were examined structural performance tests in order to verify the performance of the shear reinforcement. Shear strength of HILL01-HILL03 specimen applied to SL shear reinforcement increased about 5-14% when compared with the applied shear stirrup reinforcing existing specimens. Also, the amount of the maximum deflection of the central sub-section of HILL01-HILL03 specimen applied to SL shear reinforcement decreased about 41-42% when compared with the applied shear stirrup reinforcing existing specimens. As a result, developed SL shear reinforcement increased in shear strength and stiffness of reinforcement, structural safety is judged to be increased.

  • PDF

Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis

  • Kim, Kun-Soo;Han, Oneil;Gombosuren, Munkhtulga;Kim, Sang-Hyo
    • Steel and Composite Structures
    • /
    • v.31 no.1
    • /
    • pp.53-67
    • /
    • 2019
  • This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.