• Title/Summary/Keyword: SFRC

Search Result 209, Processing Time 0.034 seconds

Effects of Steel Fiber Properties on Compressive and Flexural Toughness of Steel Fiber-Reinforced Concrete (강섬유의 특성이 강섬유보강 콘크리트의 압축 및 휨 인성에 미치는 영향)

  • Lim, Dong-Gyun;Jang, Seok-Joon;Jeong, Gwon-Young;Youn, Da-Ae;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • Effects of tensile strength and aspect ratio of steel fiber on compressive and flexural behavior of steel fiber-reinforced concrete (SFRC) with high- and normal-strength were investigated. Also, this study explores compressive behavior of SFRC with different loading rate. For this purpose, four types of steel fiber were used for SFRC with specified compressive strength of 35 and 60 MPa, respectively. Cylindrical specimens with a diameter of 150 mm and height of 300 mm were made for compression test, and prismatic specimens with a $150{\times}150mm$ cross-section and 450 mm span length were made for flexural test. Test results from compression and flexural tests indicated that the toughness of concrete significant increased with steel fibers. Especially, using steel fiber with high tensile strength and aspect ratio can be lead to performance improvement of high-strength SFRC. In this study, equations are suggested to predict compressive toughness ratio of SFRC from flexural toughness ratio.

Shear Capacity Evaluation of High-strength SFRC Beam (고강도 SFRC보의 전단성능 평가)

  • Lee, Hyun-Ho;Keon, Young-Ho;Lee, Hwa-Jin;Chun, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.54-57
    • /
    • 2006
  • The purpose of this study is to estimate the shear strength of high-strength SFRC beam by the comparison of normal-strength SFRC beam. To achieve the goal of this study, 9th specimens were made and tested. From the analyzing test result and previous researches, the shear strengthening effect of steel fiber in high-strength is evaluated as superior than normal-strength concrete. And the proposed shear strength equation of SFRC is underestimated the shear capacity of high-strength SFRC beam. Finally, the shear strengthening effect of steel fiber in high-strength concrete is evaluated about 3.5 times larger than normal-strength concrete.

  • PDF

Dynamic behavior of RC and SFRC Beams (철근콘크리트 및 강섬유철근콘크리트보의 동적거동)

  • 강보순;황성춘;심형섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.662-667
    • /
    • 2001
  • In this paper, damping behavior of steel fiber reinforced concrete(SFRC) beams by experimental and numerical method is discussed. Because of its improved ability to dissipate energy, SFRC has a better damping behavior than that of reinforced concrete(RC). Damping behavior is influenced by longitudinal reinforcement ratio, volume and type of steel fiber, strength of concrete and the stress level. Damping in the SFRC beams has been evaluated from dynamic experimental test data at various levels of cracked states in the beams. A FEM program(TICAL) has been developed based on the relationships between curvature and damping. It is observed for SFRC beams with 0.44% of tensile reinforcement steel that approximate 5% to 35% was relatively increased in the damping ratio generally depending on the load level.

  • PDF

Damping of RC and SFRC Beams (철근콘크리트 및 강섬유 철근콘크리트보의 에너지감쇄)

  • Kang Bo-Soon
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.122-127
    • /
    • 2005
  • In this paper, damping behavior of steel fiber reinforced concrete(SFRC) beams by experimental and numerical method is discussed. Because of its improved ability to dissipate energy, SFRC has a better damping behavior than that of reinforced concrete(RC). Damping behavior is influenced by longitudinal reinforcement ratio, volume md type of steel fiber, strength of concrete and the stress level. Damping in the SFRC beams has been evaluated from dynamic experimental test data at various levels of cracked states in the beams. A FEM program(TICAL) has been developed based on the relationships between curvature and damping. It is observed far SFRC beams with 0.44$\%$ of tensile reinforcement steel that approximate 5$\%$ to 35$\%$ was relatively increased in the damping ratio generally depending on the load level.

Capacity Evaluation of High Strength SFRC Beams according to Shear Span to Depth Ratio (전단경간비에 따른 고강도 SFRC보의 성능 평가)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.76-83
    • /
    • 2014
  • The purpose of this study is to evaluate the shear strengthening effect of steel fiber in high strength SFRC beams. For this purpose, 13th specimens are prepared and structural tests are performed. Testing variables are shear span to depth ratio, steel fiber volume fraction, shear strengthening ratio in 60 MPa SFRC concrete. From the reviewing of previous researches and analyzing of material and member test results, shear span to depth ratio 2.5 and steel fiber volume fraction 1.0% can be having a maximum strengthening effect in steel fiber. Proposed shear strength estimation equation, which is considering steel fiber strengthening and shear span to depth ratio effect, underestimate the shear capacity of high strength SFRC beams. Therefore a detailed research on strength characteristics of high strength SFRC beams are needed.

Numerical Study on Columns Subjected to Blast Load Considering Compressive Behavior of Steel Fiber Reinforced Concrete (강섬유보강콘크리트의 압축거동 특성을 반영한 기둥의 내폭해석 )

  • Jae-Min Kim;Sang-Hoon Lee;Jae Hyun Kim;Kang Su Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.105-112
    • /
    • 2023
  • Steel fiber reinforced concrete (SFRC) exhibits enhanced strength and superior energy dissipation capacity compared to normal concrete, and it can also reduce crack propagation and fragmentation of concrete even when subjected to blast loads. In this study, the parameters defining failure surface and damage function of the K&C concrete nonlinear model were proposed to be applied for the properties of SFRC in LS-DYNA. Single element analysis has been conducted to validate the proposed parameters in the K&C model, which provided very close simulations on the compressive behavior of SFRC. In addition, blast analysis was performed on SFRC columns with different volume fractions of steel fibers, and the blast resistance of SFRC columns was quantitatively analyzed with Korea Occupational Safety & Health Agency (KOSHA) guidelines.

Principal Component and Multiple Regression Analysis for Steel Fiber Reinforced Concrete (SFRC) Beams

  • Islam, Mohammad S.;Alam, Shahria
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.4
    • /
    • pp.303-317
    • /
    • 2013
  • This study evaluates the shear strength of steel fiber reinforced concrete (SFRC) beams from a database, which consists of extensive experimental results of 222 SFRC beams having no stirrups. In order to predict the analytical shear strength of the SFRC beams more precisely, the selected beams were sorted into six different groups based on their ultimate concrete strength (low strength with $f_c^{\prime}$ <50 MPa and high strength with $f_c^{\prime}$ <50 MPa), span-depth ratio (shallow beam with $a/d{\geq}2.5 $and deep beam with a/d<2.5) and steel fiber shape (plain, crimped and hooked). Principal component and multiple regression analyses were performed to determine the most feasible model in predicting the shear strength of SFRC beams. A variety of statistical analyses were conducted, and compared with those of the existing equations in estimating the shear strength of SFRC beams. The results showed that the recommended empirical equations were best suited to assess the shear strength of SFRC beams more accurately as compared to those obtained by the previously developed models.

A experimental study on the long-term response of high-strength Steel-Fiber Reinforced Concrete (고강도 강섬유 보강 콘크리트의 장기거동 특성에 관한 실험적 연구)

  • Seo Jong-Myeong;Kim Jae-Ki;Lee Joo-Ha;Yoon Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.337-340
    • /
    • 2004
  • In recent days, the beneficial effects of using fiber reinforced concrete, especially Steel Fiber Reinforced Concrete, have been on the rise. However, few studies on long-term behavior of SFRC are executed in spite of great demand of SFRC. The fact that SFRC is far better than NRC in various properties such as tensile strength, ductility, flexural toughness has been certified by many researchers. And, those advantages can be also applied to decrease the structures deterioration induced by creep and shrinkage. Furthermore, even though it is fact that SFRC is generally used in joint members to distribute concentrated stresses by fibers, SFRC is treated as NRC in designing especially for long-term behavior of structures. So this paper is about a study on the long-term response of SFRC applied to HPC about 40MPa. Therefore, in this paper, the test results of eighteen high-strength concrete specimens and steel fiber-reinforced concrete specimens, with steel fiber content of $1\%$ by volume were presented. The test result shows that SFRC is advantageous rather than NRC in long-term response.

  • PDF

Crack pattern and failure mode prediction of SFRC corbels: Experimental and numerical study

  • Gulsan, Mehmet Eren;Cevik, Abdulkadir;Mohmmad, Sarwar Hasan
    • Computers and Concrete
    • /
    • v.28 no.5
    • /
    • pp.507-519
    • /
    • 2021
  • In this study, a new procedure was proposed in order to predict the crack pattern and failure mode of steel fiber reinforced concrete (SFRC) corbels. Moreover, an experimental study was carried out in order to investigate the effect of several parameters, such as compressive strength, tensile strength, steel fiber ratio, shear span on the mechanical behavior of SFRC corbels in detail. Totally, 24 RC and SFRC corbels were prepared for the experimental study. Experimental results indicate that each investigated parameter has noticeable effect on the load capacity and failure mode of SFRC corbels. Moreover, finite element (FE) model of the tested corbels were prepared and efficiency of FE model was investigated for further studies. Comparison of FE and experimental results show that there is an acceptable fit between them regarding load capacity and crack patterns. Thereafter, parametric study was carried out via FE analyses in order to obtain a methodology for crack pattern and failure mode prediction of SFRC corbels. As a result of parametric studies, a new procedure was proposed as flowcharts in order to predict the failure mode of SFRC corbels for normal and high strength concrete class separately.

Investigation on Damping of Steel Fiber Reinforced Concrete (강섬유철근콘크리트보의 에너지감쇠에 관한 연구)

  • 강보순
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.159-169
    • /
    • 2000
  • 본논문에서는 강섬유 철근 콘크리트 보(SFRC) 의 감쇄 거동에 대해서 실험적인 방법과 수치 해석적인 방법으로 연구를 수행하였다 SFRC는 보다 향상된 에너지 소산능력으로 일반 철근 콘크리트보에 비하여 뛰어난 감쇄 거동을 보인다. 감쇄거동은 종방향 철근비강섬유의 형태와 부피 콘크리트 강도 응력 수준등에 의해 영향을 받는다 SFRC보의 감쇠는 다양한 수준의 균열상태에서의 동적실험 데이터를 통하여 평가하였다 곡률과 감쇠의 관계식에 기초한 유한요소 프로그램(TICAL) 이 개발되었으며 0.44%의 강섬유를 혼입한 보의 경우 5-35%의 감쇠비 증가를 보였다

  • PDF