• Title/Summary/Keyword: SF6 gas

Search Result 567, Processing Time 0.027 seconds

A Design of UHF-Sensor for Diagnosis of Insulator (절연진단용 UHF 센서 모델 설계)

  • Choi, Eun-Hyuck;Do, Yeong-Heoi;Kim, Gi-Chai;Kim, Lee-Kook;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.115-117
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7[GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • 서판석;구경완;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation (금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향)

  • Jang, Yoon-Ki;Lee, Dong-Won;Kim, Jung-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

ABLATION OF PTFE NOZZLE DRIVEN BY ARC PLASMA (아크 플라즈마에 의한 PTFE 노즐 용삭현상)

  • Lee J.C.;Kim Y.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.311-317
    • /
    • 2005
  • It has been the most progressive interruption technique to use the ablation gas from the surface of PTFE nozzle driven by arc plasma during switching process in $SF_6$ gas circuit breakers. This advanced interruption technique can reduce the required mechanical energy to compress and blow the gas for extinguishing the arc plasma between the electrodes due to using the ablation effect instead. In order to consider the phenomena during calculation of switching process, it is required to confirm the principles of ablation from PTFE nozzle as well as of arc plasma during switching process. In this study, we have calculated the switching process considered the ablation of PTFE nozzle driven by arc plasma using multidisciplinary simulation technique and compared the results with the data without the ablation effect. More $50\%$ difference of pressure rise inside expansion chamber has been found from the results and it should be indispensable for this type of computational work to consider and include the ablation effect of PTFE nozzle. Further study on turbulence and radiation will be followed.

  • PDF

Surface Discharge Characteristics of Solid Dielectrics in N2/O2 Mixture Gas for Eco-Friendly Insulation Design (친환경 절연설계를 위한 N2/O2 혼합가스 중 고체유전체 종류에 따른 연면방전특성)

  • Lim, Dong-Young;Park, He-Rie;Choi, Eun-Hyeok;Choi, Sang-Tae;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.9-15
    • /
    • 2012
  • In this paper, we deal with a surface discharge that caused an aggravation of the dielectric strength in the $N_2/O_2$ mixture gas, When composit dielectrics were formed from the use of a solid dielectric. It was found from this study that the surface discharge voltage was deeply involved in the mixture ratio of $O_2$, the electrical property of the solid dielectric, kind of the solid dielectric, an electric field at the triple junction and a medium effect. These results expect basic data that will be used to transmission and distribution power system equipment using the $N_2/O_2$ mixture gas.

A Inquiry of Tracer Gas for Analysis of Dispersion and Prediction of Infection Possibility according to Airborne Viral Contaminants (건축공간에서 공기 감염균 확산을 해석하기 위한 추적가스 고찰과 농도에 따른 감염 위험성 예측 연구)

  • Lim, Tae-Seob;Kang, Seung-Mo;Kim, Byung-Seon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.3
    • /
    • pp.102-113
    • /
    • 2009
  • The SARS virus began to appear and spread in North America and Southeast Asia in the early 2000' s, infecting and harming many people. In the process of examining the causes for the virus, studies on the airborne SARS virus and the way it spread were carried out mainly in the medical field. In the field of architecture, studies were done on the diffusion of air pollutants in buildings using gases such as $CO_2$, $N_2O$, or $SF_6$, but research on virus diffusion was limited. There were also explanations of only the diffusion process without accurate information and discussion on virus characteristics. The aim of this study is to analyze the physical characteristics of airborne virus, consider the possibility of using coupled analysis model and tracer gas for analyzing virus diffusion in building space and, based on reports of how the infection spread in a hospital where SARS patients were discovered, analyze infection risk using tracer gas density and also diffusion patterns according to the location, shape, and volume of supply diffusers and exhaust grilles. This paper can provide standards and logical principles for evaluating various alternatives for making decisions on vertical or horizontal ward placement, air supply and exhaust installation and air volumes in medium or high story medical facilities.

Effect of Process Parameters on TSV Formation Using Deep Reactive Ion Etching (DRIE 공정 변수에 따른 TSV 형성에 미치는 영향)

  • Kim, Kwang-Seok;Lee, Young-Chul;Ahn, Jee-Hyuk;Song, Jun Yeob;Yoo, Choong D.;Jung, Seung-Boo
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.11
    • /
    • pp.1028-1034
    • /
    • 2010
  • In the development of 3D package, through silicon via (TSV) formation technology by using deep reactive ion etching (DRIE) is one of the key processes. We performed the Bosch process, which consists of sequentially alternating the etch and passivation steps using $SF_6$ with $O_2$ and $C_4F_8$ plasma, respectively. We investigated the effect of changing variables on vias: the gas flow time, the ratio of $O_2$ gas, source and bias power, and process time. Each parameter plays a critical role in obtaining a specified via profile. Analysis of via profiles shows that the gas flow time is the most critical process parameter. A high source power accelerated more etchant species fluorine ions toward the silicon wafer and improved their directionality. With $O_2$ gas addition, there is an optimized condition to form the desired vertical interconnection. Overall, the etching rate decreased when the process time was longer.

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

Analysis of Medium Effect by Gas Pressure and Gap at Surface Discharge of Dry Air (건조공기의 연면방전에서 가스압력과 극간거리에 따른 매질효과분석)

  • Lim, Dong-Young;Min, Gyeong-Jun;Park, He-Rie;Choi, Eun-Hyeok;Choi, Sang-Tae;Bae, Sung-Woo;Rhee, Sang-Bong;Park, Won-Zoo;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.86-92
    • /
    • 2013
  • In studies on an alternative insulating gas of $SF_6$ gas, the section of the alternative gas and an insulation technique to improve its low dielectric strength have been reported, but very few attempts have been made at the dependence of a gas pressure and a gap as well as the medium effect in the alternative gas. The purpose of this paper is to analyze the dependence of the gas pressure and the gap at surface flashover voltage in dry air. The dependence is analyzed based on the medium effect. The medium effect by the gas pressure and the gap can be explained by surface roughness of a solid dielectric and an electrode as well as an electric field which decreases due to the correlation between the collision ionization coefficient and the gap, respectively. In addition, an insulation technique which can fabricate a compact eco-friendly gas insulated switchgear is proposed by the results of this paper.