• Title/Summary/Keyword: SET*

Search Result 38,269, Processing Time 0.07 seconds

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

The effect of four different temperatures on the growth of Aedes albopictus larva (네 가지 다른 온도가 흰줄숲모기(Aedes albopictus) 유충 생장에 미치는 영향)

  • Na, Sumi;Jang, Hyeji;Park, Sojung;Lee, Eunyoung;Doh, Jiseon;Hong, Seungbie;Yi, Hoonbok
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.155-160
    • /
    • 2018
  • We investigated to know the growth patterns of Aedes albopictus larva at the four different temperature conditions. Each of 120 individuals was placed into a $20m{\ell}$ vial and 12 sets (a set of 10 vials) were separated into 12 water tanks ($17{\times}24{\times}18cm^3$). Each water tank was composed of 3 the $1^{st}$ instar, 3 the $2^{nd}$ instar, 2 the $3^{rd}$ instar, and 2 the $4^{th}$ instar. Three sets of water tanks were placed under the four different incubator temperatures ($17^{\circ}C$, $21^{\circ}C$, $24^{\circ}C$, $28^{\circ}C$). We found that the eclosion rates were $20.00{\pm}5.77%$ at $21^{\circ}C$ and $3.33{\pm}3.33%$ at other temperatures. For the mosquito larva mortality rate, $1^{st}$ instar was $19.24{\pm}3.65%$, $2^{nd}$ instar was $16.48{\pm}3.25%$, $3^{rd}$ instar was $23.54{\pm}5.06%$, and $4^{th}$ instar was $40.74{\pm}7.08%$. The lowest mortality rate in growth stages according to temperature was $13.33{\pm}6.67%$ at $17^{\circ}C$ in $1^{st}$ instar larva, $7.41{\pm}7.41%$ at $21^{\circ}C$ at $2^{nd}$ instar larva, $10.74{\pm}6.43%$ at $24^{\circ}C$ in $3^{rd}$ instar larva, and $20.37{\pm}5.46%$ at $28^{\circ}C$ in $4^{th}$ instar larva. The survival period of mosquitoes in underwater were $26.33{\pm}0.67days$ at $17^{\circ}C$, $23.33{\pm}1.33days$ at $21^{\circ}C$, $20.00{\pm}2.52days$ at $24^{\circ}C$, and $11.67{\pm}1.20days$ at $28^{\circ}C$. From our results the most effective temperature to the normal growth of mosquito larva was $21^{\circ}C$, and the highest mortality rate was shown at the $4^{th}$ instar stage of larva growth. Our results would provide the basic data for the mosquito larva's growth pattern.

Geological Structure of the Moisan Epithermal Au-Ag Mineralized Zone, Haenam and its Tectonic Environment at the Time of the Mineralization (해남 모이산 천열수 금-은 광호대의 지질구조와 광화작용 당시의 지구조환경)

  • Kang, Ji-Hoon;Lee, Deok-Seon;Ryoo, Chung-Ryul;Koh, Sang-Mo;Chi, Se-Jung
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.413-431
    • /
    • 2011
  • An Epithemal Au-Ag mineralized zone is developed in the Moisan area of Hwangsan-myeon, Haenam-gun, Jeol-lanam-do, Korea, which is located in the southwestern part of the Ogcheon metamorphic zone. It is hosted in the Hwangsan volcaniclastics of the Haenam Formation of the Late Cretaceous Yucheon Group. This research investigated the characteristics of bedding arrangement, fold, fault, fracture system, quartz vein and the time-relationship of the fracture system to understand the geological structure related to the formation of the mineralized zone. On the basis of this result, the tectonic environment at the time of the mineralization was considered. Beds mainly trend east-northeast and gently dip into north-northwest or south-southeast. Their poles have been rearranged by subhorizontal-upright open fold of (east)-northeast trend as well as dip-slip fault. Fracture system was formed through at least 6~7 different deformation events. D1 event; formation phase of the main fracture set of EW (D1-1) and NS (D1-2) trends with a good extensity, D2 event; that of the extension fracture of NW trend, and conjugate shear fracturing of the EW (dextral) and NS (sinistral) trends, D3 event; that of the extension fracture of NE trend, and conjugate shear refracturing of the EW (sinistral) and NS (dextral) trends, D4 event; that of the extension fracture of NS trend showing a poor extensity, D5 event; that of the extension fracture of NW trend, and conjugate shear refracturing of the EW (dextral) and NS (sinistral) trends, D6 event; that of the extension fracture of EW trend showing a poor extensity. Frequency distribution of fracture sets of each deformation event is D1-1 (19.73 %)> D1-2 (16.44 %)> D3=D5 (14.79 %)> D2 (13.70 %)> D4 (12.33 %)> D6 (8.22 %) in descending order. The average number of fracture sets within 1 meter at each deformation event is D6 (5.00)> D5 = D4 (4.67)> D2 (4.60)> D3 (4.13)> D1-1 (3.33)> D1-2 (2.83) in descending order. The average density of all fractures shows 4.20 fractures/1 m, that is, the average spacing of all fractures is more than 23.8 cm. The frequency distribution of quartz veins at each orientation is as follows: EW (52 %)> NW (28 %)> NS (12 %)> NE (8 %) trends in descending order. The average density of all quartz veins shows 4.14 veins/1 m, that is, the average spacing of all quartz veins is more than 24.2 cm. Microstructural data on the quartz veins indicate that the epithermal Au-Ag mineralization (ca. 77.9~73.1 Ma) in the Moisan area seems to occur mainly along the existing D1 fracture sets of EW and NS trends with a good extensity not under tectonic stress but non-deformational environment directly after epithermal rupture fracturing. The D1 fracturing is considered to occur under the unstable tectonic environment which alternates compression and tension of NS trend due to the oblique northward subduction of the Izanagi plate resulting in the igneous activity and deformation of the Yucheon Group and the Bulguksa igneous rocks during Late Cretaceous time.

Adaptive RFID anti-collision scheme using collision information and m-bit identification (충돌 정보와 m-bit인식을 이용한 적응형 RFID 충돌 방지 기법)

  • Lee, Je-Yul;Shin, Jongmin;Yang, Dongmin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.1-10
    • /
    • 2013
  • RFID(Radio Frequency Identification) system is non-contact identification technology. A basic RFID system consists of a reader, and a set of tags. RFID tags can be divided into active and passive tags. Active tags with power source allows their own operation execution and passive tags are small and low-cost. So passive tags are more suitable for distribution industry than active tags. A reader processes the information receiving from tags. RFID system achieves a fast identification of multiple tags using radio frequency. RFID systems has been applied into a variety of fields such as distribution, logistics, transportation, inventory management, access control, finance and etc. To encourage the introduction of RFID systems, several problems (price, size, power consumption, security) should be resolved. In this paper, we proposed an algorithm to significantly alleviate the collision problem caused by simultaneous responses of multiple tags. In the RFID systems, in anti-collision schemes, there are three methods: probabilistic, deterministic, and hybrid. In this paper, we introduce ALOHA-based protocol as a probabilistic method, and Tree-based protocol as a deterministic one. In Aloha-based protocols, time is divided into multiple slots. Tags randomly select their own IDs and transmit it. But Aloha-based protocol cannot guarantee that all tags are identified because they are probabilistic methods. In contrast, Tree-based protocols guarantee that a reader identifies all tags within the transmission range of the reader. In Tree-based protocols, a reader sends a query, and tags respond it with their own IDs. When a reader sends a query and two or more tags respond, a collision occurs. Then the reader makes and sends a new query. Frequent collisions make the identification performance degrade. Therefore, to identify tags quickly, it is necessary to reduce collisions efficiently. Each RFID tag has an ID of 96bit EPC(Electronic Product Code). The tags in a company or manufacturer have similar tag IDs with the same prefix. Unnecessary collisions occur while identifying multiple tags using Query Tree protocol. It results in growth of query-responses and idle time, which the identification time significantly increases. To solve this problem, Collision Tree protocol and M-ary Query Tree protocol have been proposed. However, in Collision Tree protocol and Query Tree protocol, only one bit is identified during one query-response. And, when similar tag IDs exist, M-ary Query Tree Protocol generates unnecessary query-responses. In this paper, we propose Adaptive M-ary Query Tree protocol that improves the identification performance using m-bit recognition, collision information of tag IDs, and prediction technique. We compare our proposed scheme with other Tree-based protocols under the same conditions. We show that our proposed scheme outperforms others in terms of identification time and identification efficiency.

Essay on Form and Function Design (디자인의 형태와 기능에 관한 연구)

  • 이재국
    • Archives of design research
    • /
    • v.2 no.1
    • /
    • pp.63-97
    • /
    • 1989
  • There is nothing more important than the form and function in design, because every design product can be done on the basis of them. Form and Function are already existed before the word of design has been appeared and all the natural and man-made things' basic organization is based on their organic relations. The organic relations is the source of vitality which identifies the subsistance of all the objects and the evolution of living creatures has been changed their appearances by the natural law and order. Design is no exception. Design is a man-made organic thing which is developed its own way according to the purposed aim and given situations. If so, what is the ultimate goal of design. It is without saying that the goal is to make every effort to contribute to the -human beings most desirable life by the designer who is devoting himself to their convenience and well-being. Therefore, the designer can be called the man of rich life practitioner. This word implies a lot of meanings since the essence of design is improving the guality of life by the man-made things which are created by the designer. Also, the things are existed through the relations between form and function, and the things can keep their value when they are answered to the right purpose. In design, thus, it is to be a main concern how to create valuable things and to use them in the right way, and the subject of study is focused on the designer's outlook of value and uk relations between form and function. Christopher Alexander mentioned the importance of form as follows. The ultimate object of design is form. Every design problem begins with an effort to achieve fittness between the form and its context. The form is the solution to the problem: the context defmes the problem. In other words, when we speak of design, the real object of discussion is not form alone, but the ensemble comprising the form and its context. Good fit is a desirable property of this ensemble which relates to some particular division of the ensemble into form and context. Max Bill mainatined how important form is in design. Form represents a self-contained concept, and its embodiment in an object results in that object becoming a work of art. Futhermore, this explains why we use form so freguently in a comparative sense for determining whether one thing is less or more beautiful than another, and why the ideal of absolute beauty is always the standard by which we appraise form, and through form, art itself. Hence form has became synonymous with beauty. On the other hand, Laszlo Moholy-Nagy stated the importance of function as follows. Function means the task an object is designed to fulfill the task instrument is shaping the form. Unfortunately, this principle was not appreciated at the same time but through the endeavors of Frank Lloyd Wright and of the Bauhaus group and its many collegues in Europe, the idea of functionalism became the keynote of the twenites. Functionalism soon became a cheap slogan, however, and its original meaning blurred. It is neccessary to reexamine it in the light of present circumstances. Charles William Eliot expressed his idea on the relations between function and beauty. Beauty often results chiefly from fittness: indeed it is easy to manitain that nothing is fair except what is fit its uses or functions. If the function of the product of a machine be useful and valuable, an the machine be eminently fit for its function, it conspicuously has the beauty of fittness. A locomotive or a steamship has the same sort of beauty, derived from the supreme fittness for its function. As functions vary, so will those beauty..vary. However, it is impossible to study form and function in separate beings. Function can't be existed without form, and without function, form is nothing. In other words, form is a function's container, and function is content in form. It can be said that, therefore, the form and function are indispensable and commensal individuals which have coetemal relations. From the different point of view, sometimes, one is more emphasized than the other, but in this case, the logic is only accepted on the assumption of recognizing the importance of the other's entity. The fact can be proved what Frank Hoyd wright said that form and function are one. In spite of that, the form and function should be considered as independent indivisuals, because they are too important to be treated just as the simple single one. Form and function have flexible properties to the context. In other words, the context plays a role as the barometer to define the form and function, also which implies every meaning of surroun'||'&'||'not;dings. Thus, design is formed under the influence of situations. Situations are dynamic, like the design process itself, in which fixed focus can be cripping. Moreover, situations control over making the good design. Judging from the respect, I defined the good design in my thesis An Analytic Research on Desigh Ethic, "good design is to solve the problem by the most proper way in the situations." Situations are changeable, and so is design. There is no progress without change, but change is not neccessarily progress. It is highly desirable that there changes be beneficial to mankind. Our main problem is to be able to discriminate between that which should be discarded and that which should be kept, built upon, and improved. Form and Function are no exception. The practical function gives birth to the inevitable form and the $$\mu$ti-classified function is delivered to the varieties of form. All of these are depended upon changeable situations. That is precisely the situations of "situation de'||'&'||'not;sign", the concept of moving from the design of things to the design of the circumstances in which things are used. From this point of view, the core of form and function is depended upon how the designer can manage it efficiently in given situations. That is to say that the creativity designer plays an important role to fulfill the purpose. Generally speaking, creativity is the organization of a concept in response to a human need-a solution that is both satisfying and innovative. In order to meet human needs, creative design activities require a special intuitive insight which is set into motion by purposeful imagination. Therefore, creativity is the most essential quality of every designer. In addition, designers share with other creative people a compulsive ingenuity and a passion for imaginative solutions which will meet their criteria for excellence. Ultimately, it is said that the form and function is the matter which belongs to the desire of creative designers who constantly try to bring new thing into being to create new things. In accordance with that the main puppose of this thesis is to catch every meaning of the form and function and to close analyze their relations for the promotion of understanding and devising practical application to gradual progression in design. The thesis is composed of four parts: Introduction, Form, Function and Conclusion. Introduction, the purpose and background of the research are presented. In Chapter I, orgin of form, perception of form, and classification of form are studied. In Chapter II, generation of function, development of function, and diversification of function are considered. Conclusion, some concluding words are mentioned.ioned.

  • PDF

The Role of the Soft Law for Space Debris Mitigation in International Law (국제법상 우주폐기물감축 연성법의 역할에 관한 연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.469-497
    • /
    • 2015
  • In 2009 Iridium 33, a satellite owned by the American Iridium Communications Inc. and Kosmos-2251, a satellite owned by the Russian Space Forces, collided at a speed of 42,120 km/h and an altitude of 789 kilometers above the Taymyr Peninsula in Siberia. NASA estimated that the satellite collision had created approximately 1,000 pieces of debris larger than 10 centimeters, in addition to many smaller ones. By July 2011, the U.S. Space Surveillance Network(SSN) had catalogued over 2,000 large debris fragments. On January 11, 2007 China conducted a test on its anti-satellite missile. A Chinese weather satellite, the FY-1C polar orbit satellite, was destroyed by the missile that was launched using a multistage solid-fuel. The test was unprecedented for having created a record amount of debris. At least 2,317 pieces of trackable size (i.e. of golf ball size or larger) and an estimated 150,000 particles were generated as a result. As far as the Space Treaties such as 1967 Outer Space Treaty, 1968 Rescue Agreement, 1972 Liability Convention, 1975 Registration Convention and 1979 Moon Agreement are concerned, few provisions addressing the space environment and debris in space can be found. In the early years of space exploration dating back to the late 1950s, the focus of international law was on the establishment of a basic set of rules on the activities undertaken by various states in outer space.. Consequently environmental issues, including those of space debris, did not receive the priority they deserve when international space law was originally drafted. As shown in the case of the 1978 "Cosmos 954 Incident" between Canada and USSR, the two parties settled it by the memorandum between two nations not by the Space Treaties to which they are parties. In 1994 the 66th conference of International Law Association(ILA) adopted "International Instrument on the Protection of the Environment from Damage Caused by Space Debris". The Inter-Agency Space Debris Coordination Committee(IADC) issued some guidelines for the space debris which were the basis of "the UN Space Debris Mitigation Guidelines" which had been approved by the Committee on the Peaceful Uses of Outer Space(COPUOS) in its 527th meeting. On December 21 2007 this guideline was approved by UNGA Resolution 62/217. The EU has proposed an "International Code of Conduct for Outer Space Activities" as a transparency and confidence-building measure. It was only in 2010 that the Scientific and Technical Subcommittee began considering as an agenda item the long-term sustainability of outer space. A Working Group on the Long-term Sustainability of Outer Space Activities was established, the objectives of which include identifying areas of concern for the long-term sustainability of outer space activities, proposing measures that could enhance sustainability, and producing voluntary guidelines to reduce risks to long-term sustainability. By this effort "Guidelines on the Long-term Sustainability of Outer Space Activities" are being under consideration. In the case of "Declaration of Legal Principles Governing the Activities of States in the Exp1oration and Use of Outer Space" adopted by UNGA Resolution 1962(XVIII), December 13 1963, the 9 principles proclaimed in that Declaration, although all of them incorporated in the Space Treaties, could be regarded as customary international law binding all states considering the time and opinio juris by the responses of the world. Although the soft law such as resolutions, guidelines are not binding law, there are some provisions which have a fundamentally norm-creating character and customary international law. In November 12 1974 UN General Assembly recalled through a Resolution 3232(XXIX) "Review of the role of International Court of Justice" that the development of international law may be reflected, inter alia, by the declarations and resolutions of the General Assembly which may to that extend be taken into consideration by the judgements of the International Court of Justice. We are expecting COPUOS which gave birth 5 Space Treaties that it could give us binding space debris mitigation measures to be implemented based on space debris mitigation soft law in the near future.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

The Jurisdictional Precedent Analysis of Medical Dispute in Dental Field (치과임상영역에서 발생된 의료분쟁의 판례분석)

  • Kwon, Byung-Ki;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.4
    • /
    • pp.283-296
    • /
    • 2006
  • Along with the development of scientific technologies, health care has been growing remarkably, and as the social life quality improves with increasing interest in health, the demand for medical service is rapidly increasing. However, medical accident and medical dispute also are rapidly increasing due to various factors such as, increasing sense of people's right, lack of understanding in the nature of medical practice, over expectation on medical technique, commercialize medical supply system, moral degeneracy and unawareness of medical jurisprudence by doctors, widespread trend of mutual distrust, and lack of systematized device for solution of medical dispute. This study analysed 30 cases of civil suit in the year between 1994 to 2004, which were selected among the medical dispute cases in dental field with the judgement collected from organizations related to dentistry and department of oral medicine, Yonsei university dental hospital. The following results were drawn from the analyses: 1. The distribution of year showed rapid increase of medical dispute after the year 2000. 2. In the types of medical dispute, suit associated with tooth extraction took 36.7% of all. 3. As for the cause of medical dispute, uncomfortable feeling and dissatisfaction with the treatment showed 36.7%, death and permanent damage showed 16.7% each. 4. Winning the suit, compulsory mediation and recommendation for settlement took 60.0% of judgement result for the plaintiff. 5. For the type of medical organization in relation to medical dispute, 60.0% was found to be the private dental clinics, and 30.0% was university dental hospitals. 6. For the level of trial, dispute that progressed above 2 or 3 trials was of 30.0%. 7. For the amount of claim for damage, the claim amounting between 50 million to 100 million won was of 36.7%, and that of more than 100 million won was 13.3%, and in case of the judgement amount, the amount ranging from 10 million to 30 million won was of 40.0%, and that of more than 100 million won was of 6.7%. 8. For the number of dentist involved in the suit, 26.7% was of 2 or more dentists. 9. For the amount of time spent until the judgement, 46.7% took 11 to 20 months, and 36.7% took 21 to 30 months. 10. For medical malpractice, 46.7% was judged to be guilty, and 70% of the cases had undergone medical judgement or verification of the case by specialists during the process of the suit. 11. In the lost cases of doctors(18 cases), 72.2% was due to violence of carefulness in practice and 16.7% was due to missing of explanation to patient. Medical disputes occurring in the field of dentistry are usually of relatively less risky cases. Hence, the importance of explanation to patient is emphasized, and since the levels of patient satisfaction are subjective, improvement of the relationship between the patient and the dentist and recovery of autonomy within the group dentist are essential in addition to the reduction of technical malpractice. Moreover, management measure against the medical dispute should be set up through complement of the current doctors and hospitals medical malpractice insurance which is being conducted irrationally, and establishment of system in which education as well as consultation for medical disputes lead by the group of dental clinicians and academic scholars are accessible.

Assessment of Estimated Daily Intakes of Artificial Sweeteners from Non-alcoholic Beverages in Children and Adolescents (어린이와 청소년의 비알콜성음료 섭취에 따른 인공감미료 섭취량 평가)

  • Kim, Sung-Dan;Moon, Hyun-Kyung;Lee, Jib-Ho;Chang, Min-Su;Shin, Young;Jung, Sun-Ok;Yun, Eun-Sun;Jo, Han-Bin;Kim, Jung-Hun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.8
    • /
    • pp.1304-1316
    • /
    • 2014
  • The aims of this study were to estimate daily intakes of artificial sweeteners from beverages and liquid teas as well as evaluate their potential health risks in Korean children and adolescents (1 to 19 years old). Dietary intake assessment was conducted using actual levels of aspartame, acesulfame-K, and sucralose in non-alcoholic beverages (651 beverages and 87 liquid teas), and food consumption amounts were drawn from "The Fourth Korea National Health and Nutrition Examination Survey (2007~2009)". To estimate dietary intake of non-alcoholic beverages, a total of 6,082 children and adolescents (Scenario I) were compared to 1,704 non-alcoholic beverage consumption subjects (Scenario II). The estimated daily intake of artificial sweeteners was calculated based on point estimates and probabilistic estimates. The values of probabilistic artificial sweeteners intakes were presented by a Monte Carlo approach considering probabilistic density functions of variables. The level of safety for artificial sweeteners was evaluated by comparisons with acceptable daily intakes (ADI) of aspartame (0~40 mg/kg bw/day), acesulfame-K (0~15 mg/kg bw/day), and sucralose (0~15 mg/kg bw/day) set by the World Health Organization. For total children and adolescents (Scenario I), mean daily intakes of aspartame, acesulfame-K, and sucralose estimated by probabilistic estimates using Monte Carlo simulation were 0.09, 0.01, and 0.04 mg/kg bw/day, respectively, and 95th percentile daily intakes were 0.30, 0.02, and 0.13 mg/kg bw/day, respectively. For consumers-only (Scenario II), mean daily intakes of aspartame, acesulfame-K, and sucralose estimated by probabilistic estimates using Monte Carlo simulation were 0.52, 0.03, and 0.22 mg/kg bw/day, respectively, and 95th percentile daily intakes were 1.80, 0.12, and 0.75 mg/kg bw/day, respectively. For scenarios I and II, neither aspartame, acesulfame-K, nor sucralose had a mean and 95th percentile intake that exceeded 5.06% of ADI.