• Title/Summary/Keyword: SE Measurement

Search Result 946, Processing Time 0.022 seconds

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

The protective effect of Citrus unshiu Peel water extract through PI3K/Akt/NF-κB signaling pathway in mice with HCl/ethanol-induced acute gastritis (HCl/ethanol로 유발한 급성 위염 마우스에서 PI3K/Akt/NF-κB 신호전달경로를 통한 진피 열수 추출물의 보호 효과)

  • Lee, Se Hui;Shin, Mi-Rae;Park, Hae-Jin;Roh, Seong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.3
    • /
    • pp.288-296
    • /
    • 2022
  • This study aimed to verify the effect of Citrus unshiu peel water extract (CUP) on a mouse model of acute gastritis (AG) induced by HCl/ethanol. Several studies have found that CUP has anti-inflammatory effects. The AG model was induced by oral administration of 150 mM HCl/60% ethanol (550 µL) to all groups except the control group. Also, for drug treatment, sucralfate (10 mg/kg) and CUP (100 or 200 mg/kg) were orally administered for 90 minutes before induction. The effect of CUP treatment was confirmed by gross gastric mucosal damage measurement, and the levels of Glutamic Oxaloacetic Transaminase (GOT), Glutamic Pyruvic Transaminase (GPT), and myeloperoxidase were reduced as well as the levels of oxidative stress biomarkers and their related proteins. In addition, the levels of inflammatory proteins, mediators, and cytokines were significantly downregulated byPI3K/Akt signaling. Taken together, these results show that CUP treatment alleviates AG by regulating PI3K/Akt signaling.

Improved Anatomical Landmark Detection Using Attention Modules and Geometric Data Augmentation in X-ray Images (어텐션 모듈과 기하학적 데이터 증강을 통한 X-ray 영상 내 해부학적 랜드마크 검출 성능 향상)

  • Lee, Hyo-Jeong;Ma, Se-Rie;Choi, Jang-Hwan
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.55-65
    • /
    • 2022
  • Recently, deep learning-based automated systems for identifying and detecting landmarks have been proposed. In order to train such a deep learning-based model without overfitting, a large amount of image and labeling data is required. Conventionally, an experienced reader manually identifies and labels landmarks in a patient's image. However, such measurement is not only expensive, but also has poor reproducibility, so the need for an automated labeling method has been raised. In addition, in the X-ray image, since various human tissues on the path through which the photons pass are displayed, it is difficult to identify the landmark compared to a general natural image or a 3D image modality image. In this study, we propose a geometric data augmentation technique that enables the generation of a large amount of labeling data in X-ray images. In addition, the optimal attention mechanism for landmark detection was presented through the implementation and application of various attention techniques to improve the detection performance of 16 major landmarks in the skull. Finally, among the major cranial landmarks, markers that ensure stable detection are derived, and these markers are expected to have high clinical application potential.

A Design of Ultra Compact S-Band PCM/FM Telemetry Transmitter (초소형 S-대역 PCM/FM 텔레메트리 송신기 설계 및 제작)

  • Jun, Ji-ho;Park, Ju-eun;Kim, Seong-min;Min, Se-hong;Lee, Jong-hyuk;Kim, Bok-ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.801-807
    • /
    • 2022
  • In this paper, we propose an ultra compact S-Band PCM/FM telemetry transmitter. The equipment is compact, so it can be applied to a limited space and capable of stable data transmission was designed and manufactured even with specifications set differently for each operating environment and system. RF direct conversion structure is used for the miniaturization of equipment, an RF transmission board, Power distribution board, and a signal processing board were implemented on a single PCB, so that the function of the transmitter could be performed with a minimum device. According to the target specification, variable output of 1~10W and variable data rate of 390kbps~12.5Mbps is possible in S-Band(2,200~2,400MHz) without degradation of performance. To verify the performance of the equipment, the RF performance test and BER measurement test were performed after the equipment was manufactured. It was confirmed that the OBW, null-to-null bandwidth, 1st IMD, Spurious emission, Phase noise specification of the PCM/FM modulated signal which is presented by the IRIG standard were satisfied, and we can confirm the data received using the transmitter inspection equipment were transmitted normally without distortion.

The Influence of Dental Hygienists' Self-Leadership on Organizational Commitment and Quality of Medical Services

  • Da-Eun Lee;Do-Seon Lim;Min-Ji Park;Se-Jeong Park;Chi-Yoon Sung;Sang-In Lee;Ha-Rim Lee;Hyoung-Joo Kim;Hee-Jung Lim
    • Journal of dental hygiene science
    • /
    • v.22 no.4
    • /
    • pp.222-232
    • /
    • 2022
  • Background: Self-leadership, an action strategy that can maximize individual capabilities, can affect the organizational commitment of dental hygienists and ultimately improve the quality of medical services. This study aims to demonstrate the need for self-leadership and organizational commitment for dental hygienists and develop measures to improve the quality of medical services. Methods: An online survey of dental hygienists working at dental hospitals and clinics in Seoul and Gyeonggi province, Republic of Korea was conducted from March 28 to May 1, 2022. A total of 341 questionnaires were returned and analyzed. The measurement tools were modified and supplemented based on the theories and models developed by Manz for self-leadership, Mowday for organizational commitment, and Cronin and Taylor for medical services. Descriptive statistics, independent t-tests, ANOVA, simple regression, and multiple regression analyses were performed using SPSS 25.0. Results: In leadership education, self-leadership is based on participation experience, the number of participants, and when and where it is received. Organizational commitment comes from participation experience, and the quality of medical services has been found to affect participation experience and location. Self-leadership had an effect on the quality of medical services (β=0.497, t=10.551, p<0.001; β=0.599, t=13.783, p<0.001; β=0.353, t=7.601, p<0.001) and organizational commitment was found to have a mediating effect. Conclusion: Dental hygienists' self-leadership has a positive effect on the quality of medical services through the formation of appropriate interrelationships within the organization. Therefore, self-leadership programs should be developed, participated in, and promoted to improve the self-leadership of dental hygienists. Moreover, hospitals should improve their environment to provide and improve self-leadership education.

Design and Fabrication of Dual Linear Polarization Stack Antenna for 4.7GHz Frequency Band (4.7 GHz 대역에서 동작하는 이중 선형편파 적층 안테나의 설계 및 제작)

  • Joong-Han Yoon;Chan-Se Yu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.251-258
    • /
    • 2023
  • In this paper, we propose DLP(Dual Linear Polarization) stack antenna for private network. The proposed antenna has general stack structure and design airgap between two substrate to obtain the maximum gain. Also, to improve cross polarization isolation, two feeding port is designed to separate for each substrate. The size of each patch antenna is 17.80 mm(W1)×16.70 mm(L1) for lower patch and 18.56 mm(W2)×18.73 mm(L2) for upper patch, which is designed on the FR-4 substrate which thickness (h) is 1.6 mm, and the dielectric constant is 4.3, and which is 40.0 mm(W)×40.0 mm(L) for total size of substrate. From the fabrication and measurement results, bandwidths of 100 MHz (4.74 to 4.84 GHz) for feeding port 1, and 150 MHz (4.67 to 4.82 GHz) for feeding port 2 are obtained on the basis of -10 dB return loss and transmission coefficient S21 is got under the -20 dB. Also, cross polarization isolation between each feeding port obtained

Taxonomic Review of Pristiophorus japonicus Complex (Pristiophoridae, Chondrichthyes) in the Northwest Pacific (북서태평양 톱상어(톱상어과, 연골어강)의 분류학적 재검토)

  • Myoung, Se Hun;Kim, Jin-Koo;Song, Choon Bok;Kai, Yoshiaki
    • Journal of Marine Life Science
    • /
    • v.1 no.1
    • /
    • pp.8-17
    • /
    • 2016
  • The family Pristiophoridae belonging to the order Pristiophoriformes consists of about 8 species and 2 genera in the world. Among them, only one species (Pristiophorus japonicus) is distributed in northwestern Pacific. The family is characterized by having an elongated and flattened rostrum with laterally projecting a low of sharp teeth. In order to clarify variability of local populations of P. japonicus, we investigated 16 individuals collected from four locations (Korea, n=6; Miyagi, n=1; Kochi Pref., n=1; Okinawa, n=8) for morphological and molecular analyses. Morphological analysis showed that there may exist three morphotypes, of which A morphotype (Korea, Miyagi, Kochi Pref.) has a short snout (26.8% of TL), being most similar to syntypes of P. japonicus. On the other hand, B morphotype (Okinawa) has a long (31.7% of TL) and wider snout (snout width at nostrils 5.2 times pre-oral length) and, C morphotype (Okinawa) has a long (31.7% of TL) and narrower snout (6.3 times). Molecular analysis using mitochondrial DNA cytochrome b DNA sequences (386 base pairs) showed that the K2P distance between A and C morphotypes were 2.1~2.7%, but those within A morphotype were 0.0~0.5%. We identified A morphotype as P. japonicus, and designated B and C morphotypes as Pristiophorus sp. 1 and Pristiophorus sp. 2, respectively. Further studies are required to elucidate the taxonomic status of two morphotypes of the sawshark in Okinawa.

A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process (LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구)

  • Kim, JoonBeom;Kang, Joon Hyuk;Chung, Eun-Kyo;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

Examination of Aggregate Quality Using Image Processing Based on Deep-Learning (딥러닝 기반 영상처리를 이용한 골재 품질 검사)

  • Kim, Seong Kyu;Choi, Woo Bin;Lee, Jong Se;Lee, Won Gok;Choi, Gun Oh;Bae, You Suk
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.6
    • /
    • pp.255-266
    • /
    • 2022
  • The quality control of coarse aggregate among aggregates, which are the main ingredients of concrete, is currently carried out by SPC(Statistical Process Control) method through sampling. We construct a smart factory for manufacturing innovation by changing the quality control of coarse aggregates to inspect the coarse aggregates based on this image by acquired images through the camera instead of the current sieve analysis. First, obtained images were preprocessed, and HED(Hollistically-nested Edge Detection) which is the filter learned by deep learning segment each object. After analyzing each aggregate by image processing the segmentation result, fineness modulus and the aggregate shape rate are determined by analyzing result. The quality of aggregate obtained through the video was examined by calculate fineness modulus and aggregate shape rate and the accuracy of the algorithm was more than 90% accurate compared to that of aggregates through the sieve analysis. Furthermore, the aggregate shape rate could not be examined by conventional methods, but the content of this paper also allowed the measurement of the aggregate shape rate. For the aggregate shape rate, it was verified with the length of models, which showed a difference of ±4.5%. In the case of measuring the length of the aggregate, the algorithm result and actual length of the aggregate showed a ±6% difference. Analyzing the actual three-dimensional data in a two-dimensional video made a difference from the actual data, which requires further research.