• Title/Summary/Keyword: SE(Silver Engineering)

검색결과 28건 처리시간 0.03초

일정 변위 진폭조건에서의 은도금한 커넥터의 미동마멸부식 거동 (Fretting Corrosion Behavior of Silver-Plated Electric Connectors with Constant Displacement Amplitude)

  • 오만진;김민정;김택영;강세형;김호경
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.99-107
    • /
    • 2014
  • Fretting corrosion tests are conducted with a constant displacement amplitude using silver-plated brass coupons to investigate the effect of contact pressure on fretting corrosion. Three behaviors are identified based on the change in electric resistance and friction coefficient during the fretting test period, and the identified behaviors are dependent on the magnitude of the applied load. The failure cycle ($N_f$) with an electric resistance of 0.1 D cannot be achieved due to the adhesion behavior of the metal and metal contact under the higher applied load of 0.45 N. This suggests that an average contact pressure higher than 159 MPa for the silver-coated connector is desirable to gain an almost infinite lifetime. The relationship between the electric contact resistance (R) and the average contact pressure (p) can be written as $p=106.2{\times}{\Omega}^{-1.5}$.

Zinc Sulfide-selenium X-ray Detector for Digital Radiography

  • Park, Ji-Koon;Kang, Sang-Sik;Kim, Jae-Hyung;Mun, Chi-Woong;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.16-20
    • /
    • 2002
  • The high bias voltage associated with the thick layer (typically 500-1000 ㎛) of selenium required to have an acceptable x-ray absorption in radiography and fluoroscopy applications may have some practical inconvenience. A hybrid x-ray detector with zinc sulfide-amorphous selenium structure has been developed to improve the x-ray sensitivity of a a-Se based flat-panel digital imaging detector. Photoluminescence(PL) characteristic of a ZnS:Ag phosphor layer showed a light emission peak centered at about 450 nm, which matches the sensitivity spectrum of selenium. The dark current of the hybrid detector showed similar characteristics with that of a a-Se detector. The x-ray sensitivity of hybrid and a-Se x-ray detector was 345 pC/㎠/mR and 295 pC/㎠/mR at an applied voltage of 10 V/㎛, respectively. The purpose of this study was to evaluate the pertinence of a solution using a thin selenium layer, as a photosensitive converter, with a thick coating of silver doped zinc sulfide phosphor.

노인의 하지 정렬 상태와 보행 시 슬관절 내전 모멘트 특성 (Relationship between lower limb alignment and knee adduction moment during ambulation in the healthy elderly)

  • 조유미;홍정화;문무성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 추계학술대회 논문요약집
    • /
    • pp.24-24
    • /
    • 2003
  • For the elderly, achieving a close-to-normal ambulation is important for activities of daily life. Recent researches of SE(Silver Engineering) restoring physical ability would help the elderly by developing the advanced gait assisting devices and orthoses. For the applications using the advanced technologies, the gait characteristics of the elderly must be understood. However, a few studies were performed to investigate the physiological or pathological gaits. The purpose of this study is to provide the gait analysis data and also to investigate relationships between alignment of the lower limb, foot progression angle and knee joint moments in the healthy elderly. By participating a total of 20 healthy elderly persons in this study, the following facts were found: 1) Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04m, Step length was 0.56m; 2) The maximum knee flexion angle through swing phase showed left 46.82$^{\circ}$, right 40.19$^{\circ}$ and the maximum knee extension angle showed left -1.32$^{\circ}$, right 2.01$^{\circ}$. Knee varus showed left 26.90$^{\circ}$, right 30.93$^{\circ}$; 3) The maximum knee flexion moment showed left 0.363 Nm/kg, right 0.464 Nm/kg, The maximum knee extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximum knee adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg. The maximum internal rotational moment showed left 0.13 Nm/kg, right 0.140 Nm/kg; 4) The subjects who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase; and 5) The subjects who had large foot progression angle had statistically lower in knee adduction moment in late stance phase.

  • PDF

금속산화물 기반의 고성능 투명 전극 및 전자파 차단 효과 (High-functional Transparent Electrode Design and Shielding Effect)

  • 조성원;차우신;하준헌;이준식;강지원;응우옌 탄 타이;김준동
    • Current Photovoltaic Research
    • /
    • 제11권1호
    • /
    • pp.13-17
    • /
    • 2023
  • Functional transparent electrode was achieved by metal oxide-metal-Metal oxide (OMO) structure. Tailoring of metal oxide and metal layers, optically transparent and electrically excellent OMO films were investigated. Silver (Ag) is adopted for the metal layer and Ag oxide (AgO) is reactively formed by flowing O2 gas during the sputtering process. This spontaneous AgO formation from Ag simultaneously provides the good electrical interface with high transparency. Due to the feature of transparent electrode of OMO, it endows the shielding effect (SE) function of electromagnetic interference. Optically transparent and electrically conductive OMO electrode shows the high transmittance (83.7%) and low sheet resistance (6.5 Ω/☐) with SE of 29.54 dB.

3D 프린터로 제작된 회로의 전기전도성 및 접착강도 향상을 위한 UV 소결 기술 (UV Treatment Technique for High Electrical Conductivity and Adhesion Strength of 3D Printed Circuit)

  • 이세훈;권오창;이유미;이헌주;문명운
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.340-340
    • /
    • 2015
  • 상지 절단 장애인들을 위한 미관형 의수는 95% 이상의 시장 보급률을 보인다. 하지만 외부 형상 향상에만 연구 초점이 맞추어져 있어 많은 장애인들이 의수를 착용할 때 차가운 표면으로 인해 이질감을 느낀다. 이로 인해 의수 제작 업체 및 절단 장애인들은 착용 시 이질감이 적은 의수의 보급을 희망하고 있다. 그러므로 본 연구에서는 인체와 유사한 온도를 발생시켜 이질감을 감소시키는 의수를 개발하기 위해 유연 기판인 TPU (Temperature Polyurethane)와 PET (Polyethylene terephthalate) 위에 상용 silver nano paste를 3D 프린터로 인쇄하였으며, UV 표면처리를 사용하여 단시간 내에 낮은 저항과, 높은 회로 접착강도를 갖는 회로를 개발 하였다.

  • PDF

Reflectivity of Sn Solder for LED Lead Frame

  • ;기세호;박상윤;김원중;정재필
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2011년도 춘계학술대회 및 Fine pattern PCB 표면 처리 기술 워크샵
    • /
    • pp.184-185
    • /
    • 2011
  • In this study, in order to obtain a high reflectivity for the LED lead frame, tin dip coating and tin plating were conducted respectively, and wettability of LED lead frame with tin solder also was tested by wetting balance tester. A Cu sheet was plated in Cu brighten electroplating bath and followed by immersion in a Sn electro-less plating bath [1]. On the other hand, in the dip coating process, a Cu sheet was dipped into molten tin. In the progress of wetting test, besides wetting balance curve, the maximum measured force($F_m$), the maximum withdrawal force($F_w$) and zero-cross time($t_0$) were obtained in various temperatures. With the maximum withdrawal force, the surface tension was calculated at different temperatures. The Cu sheet plated with bright Cu and Sn show a silver bright property while that of Cu dipped with Sn possessed a high reflectance density of 1.34GAM at $270^{\circ}C$.

  • PDF

Antibacterial and remineralization effects of orthodontic bonding agents containing bioactive glass

  • Kim, You-Min;Kim, Dong-Hyun;Song, Chang Weon;Yoon, Seog-Young;Kim, Se-Yeon;Na, Hee Sam;Chung, Jin;Kim, Yong-Il;Kwon, Yong Hoon
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.163-171
    • /
    • 2018
  • Objective: The aim of this study was to evaluate the mechanical and biological properties of orthodontic bonding agents containing silver- or zinc-doped bioactive glass (BAG) and determine the antibacterial and remineralization effects of these agents. Methods: BAG was synthesized using the alkali-mediated solgel method. Orthodontic bonding agents containing BAG were prepared by mixing BAG with flowable resin. $Transbond^{TM}$ XT (TXT) and $Charmfil^{TM}$ Flow (CF) were used as controls. Ion release, cytotoxicity, antibacterial properties, the shear bond strength, and the adhesive remnant index were evaluated. To assess the remineralization properties of BAG, micro-computed tomography was performed after pH cycling. Results: The BAG-containing bonding agents showed no noticeable cytotoxicity and suppressed bacterial growth. When these bonding agents were used, demineralization after pH cycling began approximately 200 to $300{\mu}m$ away from the bracket. On the other hand, when CF and TXT were used, all surfaces that were not covered by the adhesive were demineralized after pH cycling. Conclusions: Our findings suggest that orthodontic bonding agents containing silver- or zinc-doped BAG have stronger antibacterial and remineralization effects compared with conventional orthodontic adhesives; thus, they are suitable for use in orthodontic practice.

PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가 (Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell)

  • 박토순;이동우;김경환;권세진
    • 한국항공우주학회지
    • /
    • 제40권12호
    • /
    • pp.1063-1069
    • /
    • 2012
  • 본 연구에서는 PEM 연료전지의 경량화를 위한 방안으로 밀도가 낮고 전기전도성이 높은 마그네슘 합금을 분리판에 적용하였다. 금속 분리판 표면의 부식 및 산화 방지막 형성을 위해서 스퍼터링을 이용하여 은(silver)을 증착하였다. 최적의 증착 조건 확립을 위한 내산성 평가에 있어서 미세균열이 발생하지 않는 3 ${\mu}m$를 최적 증착 두께로 선정하고, $180^{\circ}C$에서 코팅을 수행함으로써 증착 두께의 균일성을 향상시켰다. 단일전지 구성을 위한 분리판 형상결정을 위해서 체결압, 채널 깊이에 따른 성능을 비교평가 하였다. 제작된 분리판을 이용하여 단일전지를 구성하고, 코팅 유무 및 체결압과 채널 깊이별 전류-전압 성능을 비교평가 하였다. 코팅된 마그네슘 분리판은 최대 전력밀도 192 $mW/cm^2$로, 단위 중량당 전력 밀도가 기존 금속 분리판 대비 우수함을 확인하였다.

액상환원공정을 이용한 백금 나노 입자의 합성 (Synthesis of Platinum Nanoparticles by Liquid Phase Reduction)

  • 이진호;김세훈;김진우;이민하;김영도
    • 한국분말재료학회지
    • /
    • 제19권1호
    • /
    • pp.60-66
    • /
    • 2012
  • In this study, Platinum(Pt) nanoparticles were synthesized by using polyol process which is one of the liquid phase reduction methods. Dihydrogen hexachloroplatinate (IV) hexahydrate $(H_2PtCl_6{\cdot}6H_2O)$, as a precursor, was dissolved in ethylene glycol and silver nitrate ($AgNO_3$) was added as metal salt for shape control of Pt particle. Also, polyvinylpyrrolidone (PVP), as capping agent, was added to reduce the size of particle and to separate the particles. The size of Pt nanoparticles was evaluated particle size analyzer (PSA). The size and morphology of Pt nanoparticles were observed by transmission electron microscopy (TEM) and high resolution TEM (HRTEM). Synthesized Pt nanoparticles were studied with varying time and temperature of polyol process. Pt nanoparticles have been successfully synthesized with controlled sizes in the range 5-10 and 20-40 nm with cube and multiple-cube shapes.

고효율 호흡보호구의 나노물질 입경별 제거 효율 (Fractional efficiency of Nanomaterials for the High efficiency respiratory filters)

  • 이광재;지준호;김원근;육세진;김종규;김정호
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2016
  • 본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.