• Title/Summary/Keyword: SCREEN TEST

Search Result 627, Processing Time 0.023 seconds

Evaluating the results of the Momguard noninvasive prenatal test

  • Hu, Hae-Jin;Kwon, Young-Jun;Oh, Mijin;Kim, Jihun;Cho, Dae-Yeon;Seo, Dong-Hee
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.96-99
    • /
    • 2015
  • Purpose: To evaluate the performance of the Momguard noninvasive prenatal test by tracing the 'screen positive' results based on preliminary samples from Korean cohorts. Materials and Methods: This preliminary study is based on data collected by the LabGenomics Clinical Laboratory (Seongnam, Korea) with informed consent. Only pregnant women who underwent both the Momguard test and karyotyping were included in this study. Momguard test results were compared with those of the karyotyping analysis. Results: Among the 38 cases with 'screen positive' results by Momguard, 30 cases also had karyotyping results available. In three trisomy (T) 18 and three T13 cases, the Momguard results were concordant with the karyotyping results. For the T21 cases, except for one case belonging to the mid-risk zone, Momguard results from 23 out of 24 cases matched the karyotyping results. Conclusion: Momguard is a highly reliable screening tool for detecting T13, T18, and T21 cases in independent Korean cohort samples.

A Study on the Plan Photogrammetry for Clothing Design (피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 -)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.5 no.1
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF

Supporting Materialized Views in Distributed Database Systems (저장뷰를 통한 분산 테이타베이스의 구현)

  • Lee, U-Gi;Kang, Seok-Ho;Park, Ju-Seok;Lee, Jong-Ho
    • Asia pacific journal of information systems
    • /
    • v.5 no.2
    • /
    • pp.131-142
    • /
    • 1995
  • In distributed database systems materialized views are useful to solve many problems caused by data replication. This paper deals with the problem of updating materialized views incluing join operations. We use a differential update which uses logs that record the change of base tables in certain periods. This method avoids locking of the base tables so that it makes the system more efficient. We update materialized views periodically to save the updating cost envolved. A screen test is applied to differential files to eliminate tuples that are irrelevant to any of the views being updated. Using these methods, a detailed procedure is addressed to refresh materialized views. Then we show that our update procedure performs better than a semijoin approach.

  • PDF

Experimental study on the working characteristic of a heat pipe with combined wick (조합형 윅을 사용한 히트파이프의 작동특성에 관한 실험적 연구)

  • 홍진관;부준홍;정원복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.236-243
    • /
    • 1999
  • Aluminum/Freon-22 heat pipes were manufactured and tested which have a special wick geometry combining axial groove and screen mesh. There were 14 axial grooves in a cross-section and these were covered by two layers of 350 mesh screens to enhance the thermal performance. The performance test was conducted by varying the thermal load and tilt angle. Furthermore, the operation limits and overall heat transfer coefficient were investigated. The experimental results will be useful in a variety of applications, especially in design and manufacturing of a high-efficiency heat exchanger and energy recovery systems.

  • PDF

Quality Evaluation of Fresh ginseng by Soft X-ray and iodine Test. (연X선 및 요드반응에 의한 수삼의 품질평가)

  • Park, Hoon;Cho, Byung-Goo;Lee, Mee-Kyung
    • Journal of Ginseng Research
    • /
    • v.8 no.2
    • /
    • pp.167-171
    • /
    • 1984
  • Soft X-ray is useful to identify the quality of fresh ginseng causing the inside cavity or white pan of red ginseng. The portion of low mass density identified by the difference in absorption of soft X-ray showed lower dry matter density and less or no response to iodine test indicating less accumulation or excess consumption of starch. The inside white part of red ginseng absorbed less X-ray than the normal part did. Probability for identification of the inside cavity or white at fresh ginseng was rather high (80-90%) in screen observation than f'3m reading and seemed to be increased further by using the developed screen and with training. The inside white of red ginseng appeared to be due to starch deficiency. Dry matter density appeared to be better than fresh weight density for the quality criterion.

  • PDF

A new contrast ratio measurement method using image patterns

  • Choi, Dong-Wook;Yang, Sun-A;Bae, Jae-Woo;Lee, Seung-Bae;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.85-87
    • /
    • 2011
  • The contrast ratio is one of the most important performance parameters for display devices. The general method of measuring the contrast ratio is to determine the ratio of the full-screen white pattern to the full-screen black pattern, according to the Video Electronics Standards Association standard. Real TV images seldom have these images, however, and the conventional method does not reflect the true performance of the display in actual use. In this paper, a new contrast ratio measurement method that uses image patterns is proposed, to demonstrate that active matrix organic light-emitting diode TVs have a higher contrast than LED (LCD) TVs.

Minimum Hellinger Distance Bsed Goodness-of-fit Tests in Normal Models: Empirical Approach

  • Dong Bin Jeong
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.3
    • /
    • pp.967-976
    • /
    • 1999
  • In this paper we study the Hellinger distance based goodness-of-fit tests that are analogs of likelihood ratio tests. The minimum Hellinger distance estimator (MHDE) in normal models provides an excellent robust alternative to the usual maximum likelihood estimator. Our simulation results show that the Hellinger deviance test (Simpson 1989) based goodness-of-fit test is robust when data contain outliers. The proposed hellinger deviance test(Simpson 1989) is a more direcct method for obtaining robust inferences than an automated outlier screen method used before the likelihood ratio test data analysis.

  • PDF

Comparison of Heat Insulation Characteristics of Multi-layer Thermal Screen and Development of Curtain System (다겹보온자재의 보온성 비교 및 커튼개폐장치 개발)

  • Lee, Si-Young;Kim, Hark-Joo;Chun, Hee;Yum, Sung-Hyun;Lee, Hyun-Joo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • This study was accomplished to compare energy saving effects of several heat insulation materials in greenhouse and to develop new automatic opening and closing equipment which is suitable to the most effective heat insulation material. To find out more effective heat insulation material, the magnitude of heat transfer occurred through aluminum screen (ALS), non-woven fabric (NWF), double-layer aluminum screen with chemical cotton sheet (DAL), and multi-layer fabric screen material quilted with non-woven fabric, chemical cotton, poly foam, and polypropylene (MLF) were compared relatively. The results showed that the relative magnitude of heat transfer occurred through MLF was lower than DAL and ALS by 23.3% and 43.0% respectively. MLF screen material was the most effective compared with other heat insulation materials. But because of thickness, there was a need of new mechanism for automatic operation in greenhouse. Accordingly, new screen system using MLF-thick but profitable for keeping warm in greenhouse-was developed. Opening & closing equipment was designed to roll MLF with pipe axis during opening process and pull MLF with string during closing process with electric motors, clutches, drums, and so on. In hot pepper cultivation and energy saving test during winter time, the early stage yield of pepper under MLF screen system was higher than NWF by 27%, and gasoline consumption of MLF screen system was lower than NWF by 46%.

Improvement and Promotion Plan for the Screen Baseball Utilization (스크린야구 이용의 개선 및 증진방안)

  • Koo, Soo-Yong;Jeon, Yong-Bae;Choi, Eui-Yul
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.4
    • /
    • pp.363-372
    • /
    • 2015
  • The purpose of this study was to suggest marketing plan to improve and promote screen baseball utilization, applying Importance-Performance Analysis (IPA) incorporating marketing mix 4Cs; Customer value, Convenience, Cost, and Communication. A convenience sample was made up of 267 users in screen baseball clubs located in metropolitan area. Evidence on validity and reliability of the data was obtained through exploratory factor analysis and internal consistency analysis. Frequency analysis and paired sample t-test for the difference verification of IPA were conducted also in SPSS version 21.0 with .05 of significance level. The main results of the study were as follows. First, there were partially significant differences between importance and satisfaction regarding the sub-categories of Customer value and Convenience. Second, there were all significant differences between importance and satisfaction regarding the sub-categories of Cost and Communication. Third, as the results regarding IPA, quadrant I indicating 'Keep up Good Work' included healthy use of leisure time, improvement of self-achievement, accessibility, communication between service user and provider, etc. Fourth, quadrant II indicating 'Concentrate Here' included diversification of screen baseball program, cost regarding facility use, etc. Fifth, quadrant III indicating 'Low Priority' included interpersonal relationship, subsidiary facilities, cost of food and beverage, etc. Lastly, quadrant IV indicating 'Possible Overkill' included improvement of physical health and life satisfaction and rules and procedures of screen baseball.

Durability and Characteristics of Ag-Pd Rod Heater for Bidet Fabricated by Screen Printing Process (스크린 프린팅 공정에 의해 제조된 비데용 Ag-Pd 봉형 발열체의 내구성 및 물성 평가 )

  • Tae-Ung Park;Da-Eun Hyun;Ik-Soo Kim;Sung-Chul Lee;Yeon-Sook Lee;Yong-Nam Kim;Dong-Won Lee;Jong-Min Oh
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.81-87
    • /
    • 2023
  • Heaters using the resistance heating principle are used in various industrial fields that require heat and are also essentially used in bidet among small home appliances. A planar heater and a coil-inserted heater mounted on a conventional commercially used bidet have disadvantages and limitations of complicated manufacturing process and local heating. In this study, silver-palladium (Ag-Pd) powder material was used for a screen-printing process that is more advantageous in achieving simplification than the existing process, and a rod-type heater for bidet was manufactured. The on-off cycle test under actual conditions was conducted to confirm the durability and the capability of the fabricated heater, and the fabricated heater operated more than 2,600 on-off cycles, which means it could be applied for a commercial product. In addition, through the on-off cycles under harsh conditions, the cause of failure was identified after the test that the durability limit temperature of the heater was 850℃. Through Ag-Pd rod heater in this study, it is expected to contribute to the efficient development of electrode materials for heaters and the improvement of the durability of heaters in the future.